Setting/ Anchor Bolt Calculation

Operating Weight,
Bending moment,
Bolt Center Diameter,
Material
Allowable Stress,
Bolt Size
Area
Lugs Quantity

W =
M=
Rlug =
=
Sb =
=
Ab =
Nlug =

3540
kg
= 34692
N
1310.6 Nm
1592
mm = 1.864
m
SA-193 B7
2
172
MPa = 1753.912 kgf/cm
M24
2
3.3826 cm
4

Force on one lug, operating condition (Flug)

Flug

M lug
W
= 9024.545 N

N lug
( Rlug N lug / 2)
= 920.2473 kgf

Required area per bolt

Flug

2
0.525 cm

Sb

The area provided by specified setting bolt (3.3826 cm 2) is adequate