1. Determine Inlet Parameters & Properties, i.e.

, Pressure, Temperature, Flow rate & then Steam Quality, Specific Entropy, Sp
2. Specific enthalpy is multiplied by Mass flow to get energy flow.
3. Calculate ideal outlet parameters & properties i.e., Pressure, Temperature & then Specific Enthalpy, Specific Entropy (Inlet
4. Calculate Steam Turbine Isentropic Efficiency using formula ; (In Sp.E - Out Sp.E)/(In Sp.E - Out Ideal Sp.E)
5. Calculate Steam Turbine Energy out from Formula; (In Sp.E - Out Sp.E) * Mass Flow
6. Power out = Energy Out * Generator Efficiency

team Quality, Specific Entropy, Specific Enthalpy

c Enthalpy, Specific Entropy (Inlet entropy equals outlet entropy).


- Out Ideal Sp.E)

Inlet Parameters
Steam Pressure
Steam Temperature
Steam Flow Rate

51 bar (g)
427 C
9 kg/h

Steam Quality
Specific Entropy
Specific Enthalpy
Energy Flow

Outlet Parameters

1
6.722 kJ/kgK
3259 kJ/kg
29331

Steam Pressure
Steam Temperature

Steam Quality
Specific Entropy
Specific Enthalpy
Ideal Outlet Sp. Enthalpy

kJ/h

Isentropic Efficiency
(Inlet Specific Enthalpy - Outlet Specific Enthalpy)/ (Inlet Specific Enthalpy - Ideal Outlet Specific Enthalpy)
Efficiency

0.566305254

Steam Turbine Energy Out


Energy

6111

kJ/h

Power Out
Generator Efficiency
Power Out

0.985
6019.335

%
kW

Outlet Parameters
-0.91 bar (g)
43 C

1
8.19 kJ/kgK
2580 kJ/kg
2060 kJ/kg

Inlet Parameters
Steam Pressure
Steam Temperature
Steam Flow Rate

51 bar (g)
427 C
9 kg/h

Steam Quality
Specific Entropy
Specific Enthalpy

700

1
6.722 kJ/kgK
3259 kJ/kg

Energy Flow

29331

kJ/h

Isentropic Efficiency
(Inlet Specific Enthalpy - Outlet Specific Enthalpy)/ (Inlet Specific Enthalpy - Ideal Outlet Specific Enthalpy)
Efficiency
Outlet Sp. Enthalpy

0.566305254
56.63052544
3260.849972

%
kJ/kg

Steam Turbine Energy Out


Energy

16.64974619

kJ/h

Power Out
Generator Efficiency
Power Out

98.5
1640

%
kW

Outlet Parameters
Steam Pressure
Steam Temperature

-0.91 bar (g)


43 C

Steam Quality
Specific Entropy
Specific Enthalpy
Ideal Outlet Sp. Enthalpy
Sensible Heat

1
8.19
2580
2060
183

Outlet Specific Enthalpy)

kJ/kgK
kJ/kg
kJ/kg
kJ/kg

316 K

Carnot Efficiency
0.548571429
54.85714286
Rankine Cycle Efficiency
0.220741222
22.07412224

arnot Efficiency
%

ine Cycle Efficiency


%

Inlet Parameters

Outlet Parameters

Steam Pressure
Steam Temperature
Steam Flow Rate

749.7 psig
800.6 F
9 kg/h

Steam Pressure
Steam Temperature

Steam Quality
Specific Entropy
Specific Enthalpy

1
2.233 Btu/lbF
-5484 Btu/lb

Steam Quality
Specific Entropy
Specific Enthalpy

Actual Power
Power Out

1.64
1.664974619
2231.869463
5680107.783

MW
MW hours of power
hp
BTU/hr

Amount of Steam used


Steam Flowrate
Amount of Steam

19.836
lb/h
-986.1298234 lb/h

Steam Turbine Efficiency


Efficiency

-49.71414718 %

Outlet Parameters
-13.377 psig
109.4 F

2.602 Btu/lbF
-5760 Btu/lb

You might also like