Jk-Rec-C 0022

You might also like

Download as xls, pdf, or txt
Download as xls, pdf, or txt
You are on page 1of 20

ACTIVE

Title
Group Setting
Default Group
ADGS(Auto Default Group Setting) Function
Reverse Group

Setting
1
OFF
1

GROUP 1 ~ 4
FAULT DETECTION
Title
PHASE
Pickup Level
F TCC Type
F Multiplier
F Time Adder
F Min Response Time
F Reset Type
F RDMT
D TCC Type
D Multiplier
D Time Adder
D Min Response Time
D Reset Type
D RDMT
DTOC Active
DTOC Level
DTOC Time
HOC Level
HOC Time
Cold Load Multiplier
Cold Load Time
Inrush Multiplier
Inrush Time
2nd Harmonic Block
Fault Trip Direction
GROUND
Pickup Level
F TCC Type
F Multiplier
F Time Adder
F Min Response Time
F Reset Type
F RDMT
D TCC Type
D Multiplier
D Time Adder
D Min Response Time
D Reset Type
D RDMT
DTOC Active
DTOC Level
DTOC Time

GROUP 1 GROUP 2 GROUP 3 GROUP 4 Unit


410
A
1
0
0
RDMT
0
B
1
0
0
RDMT
0
OFF
1000
0
500
0
4
0
4
0.2
YES
NONE

400
A
1
0
0
RDMT
0
B
1
0
0
RDMT
0
OFF
1000
0
500
0
2
0
2
0.2
YES
NONE

400
A
1
0
0
RDMT
0
B
1
0
0
RDMT
0
OFF
1000
0
500
0
2
0
2
0.2
YES
NONE

400
A
1
0
0
RDMT
0
B
1
0
0
RDMT
0
OFF
1000
0
500
0
2
0
2
0.2
YES
NONE

60
1
1
0
0
RDMT
0
2
1
0
0
RDMT
0
OFF
1000
0

60
1
1
0
0
RDMT
0
2
1
0
0
RDMT
0
OFF
1000
0

60
1
1
0
0
RDMT
0
2
1
0
0
RDMT
0
OFF
1000
0

60
1
1
0
0
RDMT
0
2
1
0
0
RDMT
0
OFF
1000
0

Sec
Sec
Sec

Sec
Sec
Sec
A
Sec
%
Sec
Min
Sec

Sec
Sec
Sec

Sec
Sec
Sec
A
Sec

HOC Level
1500
HOC Time
0
Cold Load Multiplier
4
Cold Load Time
0
Inrush Multiplier
4
Inrush Time
0.2
2nd Harmonic Block
YES
Fault Trip Direction
NONE
SEF
3Io Pickup
5
-3Vo Pickup
30
Max. Torque Angle
90
Detection Time
1
Reset Time
0
2nd Harmonic Block
YES
Function In Use
OFF
Negative Phase Current Sequence (NPS)
I2 Pickup Level
400
Detection Time
0.1
2nd Harmonic Block
YES
Function In Use
OFF
2ND HARMONIC DETECTION
2nd Harmonic Level
20
Detection Time
0.02
Function In Use
ON
DIRECTION
3V1 Threshold
20
3I1 Threshold
20
3I1 Max. Torque Angle
300
-3Vo Threshold
20
3Io Threshold
20
3Io Max. Torque Angle
330

500
0
2
0
2
0.2
YES
NONE

500
0
2
0
2
0.2
YES
NONE

500
0
2
0
2
0.2
YES
NONE

%
Sec

5
30
90
1
0
YES
OFF

5
30
90
1
0
YES
OFF

5
30
90
1
0
YES
OFF

A
%
DEG
Sec
Sec

400
0.1
YES
OFF

400
0.1
YES
OFF

400
0.1
YES
OFF

A
Sec

20
0.02
ON

20
0.02
ON

20
0.02
ON

%
Sec

20
20
300
20
20
330

20
20
300
20
20
330

20
20
300
20
20
330

%
%
DEG
%
%
DEG

Min
Sec

OPEN LINE DETECTION


Title
Volt ON Level
Volt OFF Level
Delay Time
Function In Use

GROUP 1 GROUP 2 GROUP 3 GROUP 4 Unit


80
80
80
80
%
50
50
50
50
%
0.4
0.4
0.4
0.4
Sec
ON
ON
ON
ON

UNDER VOLTAGE
Title
Pickup
Delay Time
Function In Use

GROUP 1 GROUP 2 GROUP 3 GROUP 4 Unit


80
80
80
80
%
1
1
1
1
Sec
OFF
OFF
OFF
OFF

OVER VOLTAGE
Title
Pickup
Delay Time
Function In Use

GROUP 1 GROUP 2 GROUP 3 GROUP 4 Unit


120
120
120
120
%
1
1
1
1
Sec
OFF
OFF
OFF
OFF

UNDER FREQUENCY
Title
Pickup
Delay Time
Function In Use

GROUP 1 GROUP 2 GROUP 3 GROUP 4 Unit


49.8
49.8
49.8
49.8
Hz
0.1
0.1
0.1
0.1
Sec
OFF
OFF
OFF
OFF

OVER FREQUENCY
Title
Pickup
Delay Time
Function In Use

GROUP 1 GROUP 2 GROUP 3 GROUP 4 Unit


60.2
60.2
60.2
60.2
Hz
0.1
0.1
0.1
0.1
Sec
OFF
OFF
OFF
OFF

SYNCHRO. CHECK
Title
Phase Difference
Delay Time
Function In Use

GROUP 1 GROUP 2 GROUP 3 GROUP 4 Unit


30
30
30
30
DEG
0.1
0.1
0.1
0.1
Sec
ON
ON
ON
ON

ANALOG ALARM
Title
ANALOG HIGH ALARM
Phase Current
Ground Current
NPS Current
Phase Voltage
System Power
Function In Use
ANALOG LOW ALARM
Phase Current
Ground Current
NPS Current
Phase Voltage
System Power
Function In Use

GROUP 1 GROUP 2 GROUP 3 GROUP 4 Unit


16000
16000
16000
38000
54000
OFF

16000
16000
16000
38000
54000
OFF

16000
16000
16000
38000
54000
OFF

16000
16000
16000
38000
54000
OFF

A
A
A
V
K

0
0
0
0
0
OFF

0
0
0
0
0
OFF

0
0
0
0
0
OFF

0
0
0
0
0
OFF

A
A
A
V
K

TRIP & RECLOSING


Title
PHASE/GROUND
Phase Operation Count
Ground Operation Count
Phase Fast Count
Ground Fast Count
Phase HCT Operation Count
Ground HCT Operation Count
Dead Time 1st
Dead Time 2nd
Dead Time 3rd
Dead Time 4th
Reset Time
SEF

GROUP 1 GROUP 2 GROUP 3 GROUP 4 Unit


4
4
2
2
0
0
0.6
2
15
15
30

4
4
2
2
0
0
0.6
2
15
15
30

4
4
2
2
0
0
0.6
2
15
15
30

4
4
2
2
0
0
0.6
2
15
15
30

Sec
Sec
Sec
Sec
Sec

SEF Operation Count


Dead Time 1st
Dead Time 2nd
Dead Time 3rd
Dead Time 4th
Reset Time
SINGLE SHOT TIME
Time
SEQ. COORDINATION
Active

4
0.6
2
15
15
30

4
0.6
2
15
15
30

4
0.6
2
15
15
30

4
0.6
2
15
15
30

Sec
Sec
Sec
Sec
Sec

10

10

10

10

Sec

OFF

OFF

OFF

OFF

I/O
Title
AC RATING
Line Configuration
System Frequency
Rated Voltage ( L - L )
Reference Voltage ( L - N )
Reference Phase
CT ratio
CT Direction
NCT ratio
NCT Direction
Phase Rotation
Sample Frequency
VT Type
VT Secondary Voltage
DEMAND SETTING
Block Interval
Roll Interval
ENERGY PROFILE
Profile Type
Demand Reset Day
Demand Reset Date
WAVEFORM TRIGGER
Pre-1st Cycle
Post-2nd Cycle
Pre-2nd Trigger Cycle
CLOSE INTERLOCK
Live Load
Sync.Fail
CAN DO PULSE TIME
Battery Pulse Width
FI RESET METHOD
FI Reset Select
FI Time Out
VOLTAGE DISPLAY
Voltage Display
AUTOMATIC BATTERY
Checking Cycle
Checking Time (Hour)
Checking Time (Min)
FI TYPE SELECT
FI Type Select
SWITCH OPERATION COUNT
Open Count
ENERGY COUNTER
Holding at Midnight

PQM

Setting
Y-G
50
22000
12700
A
1000
FWD
1000
FWD
A-B-C
128
INT_6CVT
NOT USED

Unit

Hz
V
V

S/C

30 Min
30 Min

Min
Min

MONTHLY
MON
1

Day
Date

2
2
10
YES
YES
1000

ms

MANUAL
0

Hour

L-L
0
0
0
TRIP
0
ENABLE

Day
Hour
Min

Title
Voltage Unbalance
Voltage Unbalance Detection Level
Voltage Unbalance Detection Time
Current Unbalance
Current Unbalance Detection Level
Current Unbalance Detection Time
Sag
Sag Detection Level
Sag Detection Cycle
Swell
Swell Detection Level
Swell Detection Cycle
Interruption
Interruption Detection Level
Interruption Detection Cycle
Voltage THD Alarm
Alarm Level
Detection Time
Current THD Alarm
Alarm Level
Detection Time
* ATTENTION
Detection level or alarm level settings for all PQM functions
can be set with the value 0 for disabling the function.

Setting

Unit

30
1

%
Sec

30
1

%
Sec

0.9
2

PU
Cycle

1.2
2

PU
Cycle

0.1
2

PU
Cycle

0
0.4

%
Sec

0
0.4
1.#INF00
1.#INF00
1.#INF00

%
Sec

Setting

Unit

9600
1
DNP

Bps

COMMUNICATION
PORT PARAMETERS
Title
SCADA PORT
Serial Port Speed
Slave Address
Protocol
MODEM CONTROL
Line
RTS Off dealy
CTS Timeout
DCD Timeout
RTS/CTS Control
CTS to message delay
Parity (Applicable only to IEC)
PSTN Configuration (Applicable only to DNP3.0)
PSTN MODEM
Auto Hang-up Time
Dial Timeout
Attempt Delay
Max Attempts
Phone Number #1
Phone Number #2

FULL-DUFLEX
50
2
5
USED
0
EVEN
NOT USED
30
90
60
3

ms
Sec
Sec
ms

Sec
Sec
Sec

Phone Number #3
Phone Number #4
Phone Number #5
Phone Number #6
Phone Number #7
Phone Number #8
Phone Number #9
Phone Number #10
TIME ZONE
UTC Offsets (Hour)
UTC Offsets (Min)
UTC Option
Mode
PPP Configuration
APN(Access Point Name)
User Name
Password
Fixed Our IP Address
Fixed Their IP Address
Fixed DNS-1 IP Address
Fixed DNS-2 IP Address
SMS Message Configuration
Switch Name
FI
Open/Close
Door Open
AC Fail

0
0

Hour
Min

LOCAL

0.0.0.0
0.0.0.0
0.0.0.0
0.0.0.0

DISABLE
DISABLE
DISABLE
DISABLE

DNP3.0 PARAMETERS
Title
D/L Retries
D/L Timeout
D/L Confirm
A/L Retries
A/L Timeout
Initial Unsolicited MSG
Unsolicited Class 1 Delay Time
Unsolicited Class 2 Delay Time
Unsolicited Class 3 Delay Time
Arm Timeout
Unsolicited Address
Multi Frame Interval
Analog Event Mode
Unsolicited Class 1
Unsolicited Class 2
Unsolicited Class 3

Setting
0
30
SOMETIMES
1
40
NO
5
5
5
15
65534
100
SOE
DISABLE
DISABLE
DISABLE

Unit

Setting
SCALED

Unit

Sec

Sec
Sec
Sec
Sec
Sec
ms

IEC PARAMETERS
Title
Analog Value Type

Analog Event Mode


A/L Cyclic Period
Arm Timeout
M_SP Cyclic
M_DP Cyclic
M_ME Cyclic
M_SP Start Address
C_SC Start Address
M_DP Start Address
C_DC Start Address
M_ME Start Address
C_SE Start Address
M_IT Start Address
IEC101 PARAMETERS
Link Address Size
Common Address Size
Object Address Size
COT Size
Time Marker
Single NACK Control
Link Mode

SOE
0
15
DISABLE
DISABLE
ENABLE
100
200
300
400
1000
2000
4000
2
2
2
1
CP56
YES
UNBALANCED

Sec
Sec

I/O
Index Date & Time Description Status

FUNCTION
Index Date & Time Description Status

SYSTEM
Index Date & Time Description Status

FAULT I
Index Date & Time OC SEF NOC TRIP UV OV DIR Inrush Ia Ib Ic In Vo Group

PQM
Index Date & Time Description Value(kV) Duration(ms)

DEMAND I
Index Date & Time Ia

Ib

Ic

In

DEMAND P
Index Date & Time kWa

kWb

kWc

kW3ph

kVARa

kVARb

kVARc

kVAR3ph

Quadrant

DAILY PEAK DEMAND I


Index Date & Time Ia

Ib

Ic

In

DAILY PEAK DEMAND P


Index Date & Time kWa

kWb

kWc

kW3ph

kVARa

kVARb

kVARc

kVAR3ph

ENERGY & PEAK DEMAND


Index
Energy Reset Date & Time
P+ A Energy [kWh]
P+ B Energy [kWh]
P+ C Energy [kWh]
P+ 3 Energy [kWh]
P- A Energy [kWh]
P- B Energy [kWh]
P- C Energy [kWh]
P- 3 Energy [kWh]
Q1 A Energy [kVARh]
Q1 B Energy [kVARh]
Q1 C Energy [kVARh]
Q1 3 Energy [kVARh]
Q3 A Energy [kVARh]
Q3 B Energy [kVARh]
Q3 C Energy [kVARh]
Q3 3 Energy [kVARh]
Q4 A Energy [kVARh]
Q4 B Energy [kVARh]
Q4 C Energy [kVARh]
Q4 3 Energy [kVARh]
Q2 A Energy [kVARh]
Q2 B Energy [kVARh]
Q2 C Energy [kVARh]
Q2 3 Energy [kVARh]
Peak Demand Ia [A]
Peak Demand Ib [A]
Peak Demand Ic [A]
Peak Demand In [A]
Peak Demand P+ A [kW]
Peak Demand P+ B [kW]
Peak Demand P+ C [kW]
Peak Demand P+ 3 [kW]
Peak Demand P- A [kW]
Peak Demand P- B [kW]
Peak Demand P- C [kW]
Peak Demand P- 3 [kW]
Peak Demand Q1 A [kVAR]
Peak Demand Q1 B [kVAR]
Peak Demand Q1 C [kVAR]
Peak Demand Q1 3 [kVAR]
Peak Demand Q3 A [kVAR]
Peak Demand Q3 B [kVAR]
Peak Demand Q3 C [kVAR]
Peak Demand Q3 3 [kVAR]
Peak Demand Q4 A [kVAR]
Peak Demand Q4 B [kVAR]
Peak Demand Q4 C [kVAR]

Peak Demand Q4 3 [kVAR]


Peak Demand Q2 A [kVAR]
Peak Demand Q2 B [kVAR]
Peak Demand Q2 C [kVAR]
Peak Demand Q2 3 [kVAR]