Professional Documents
Culture Documents
Building Design
Building Design
PRELIMINARY DESIGN
MAIN BEAM
Largest span of beam, m:
Span/ effictive depth ratio:
Effective Depth, mm:
Effective Depth taken, mm:
Using effective cover, mm:
Overall Depth, mm:
Width of Beam, mm:
Size of Beam mm*mm:
6.30
13.50 Clause 23.2.1.a, IS: 456-2000
466.59
500.00
40.00
540.00
400.00
400*540
SECONDARY BEAM
Largest span of beam, m:
Span/ effictive ratio:
Effective Depth, mm:
Effective Depth taken, mm:
Using effective cover, mm:
Overall Depth, mm:
Width of Beam, mm:
Size of Beam mm*mm:
5.16
13.50 Clause 23.2.1.a, IS: 456-2000
381.93
400.00
40.00
440.00
400.00
400*440
SLAB
Maximum Length, lx, m:
Span/ overall depth ratio:
Modification factor:
Effective Depth, mm:
Effective depth taken,mm
Using effective cover, mm:
Overall depth taken, mm:
5.00
26.00 Clause 23.2.1.e, IS: 456-2000
1.70 From fig. 4 fs=240, Pt=2%
113.21 Clause 23.2.1.e, IS: 456-2000
115.00
25.00
140
PRELIMINARY DESIGN
COLUMN
Effective area:
column contd.
Slab Load on Column
Slab (14nos.*23.5*17.374*0.140)
KN
Floor finish:
Screeding
(14nos.*22*17.374*0.05) KN
Ceiling Plaster
(14nos.*20.4*17.374*.012) KN
Beam load on column
Main Beam effective length, m
Secondary Beam effective length,
m
Loads
(14nos.*23.5*4.089*.54*.4+14nos.
*23.5*4.597*.54*.4) KN.
Wall load on column
Ground floor KN
Floor (1 to13) KN
Live Load on column
Floor (14no.*17.374*2) KN
Toal Load on Column, KN
Factored Load on Column, kN
(FoS=1.5), Pu
Assuming % of Steel = 4.0%
f ck,mpa
fy,mpa
From IS:456-2000 (39.3)
Pu=0.4fck*Ac+0.67*fy*Asc
5085.14*1000=0.4*24*(10.04)*Ag+0.67*500*0.04*Ag
Gross area of column (Ag):
Use Column Section of 500*500
mm
17.37
800.25
267.56
59.54
8.69
12.52
617.26
69.20
82.20
486.47
3390.10
5085.14
35.00 Mpa
500.00 Mpa
224847.13 mm2
474.18
mm