SuperArc LA-100 Suite

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

MIG (GMAW) WIRE

SuperArc LA-100

(AWS ER100S-G, ER110S-G & EM2)

MECHANICAL PROPERTIES (1) As Required per AWS A5.28/A5.28M: 2005

Requirements - AWS ER100S-G


As-Welded - Gas Not Specified
AWS ER110S-G
As-Welded - Gas Not Specified
MIL-100S-1 per MIL-E-23765/2C, 2D, 2E
& T9074-BC-G1B-010/0200
As-Welded with 98% Ar /2% O2
Typical Results
As-Welded at 30 kJ/in with 95% Ar/5% CO2
As-Welded at 45 kJ/in with 98% Ar/2% O2

Yield
Strength(2)
MPa (ksi)

Tensile
Strength
MPa (ksi)

Elongation
%

Charpy V-Notch
J (ftlbf)
@ -18C (0F) @ -51C (-60F)

Not Specified

690 (100) min.

Not Specified

Not Specified

Not Specified

Not Specified

760 (110) min.

Not Specified

Not Specified

Not Specified

565-825 (82-120)

Not Specified

16 min.

81 (60) min.

47 (35) min.

750 (109)
730 (106)

790 (115)
780 (114)

22
20

164 (121)
- -

138 (102)
118 (87)

580 (84)

745 (108)

25

138 (102)

70 (52)

620 (90)
682 (99)

740 (107)
765 (111)

25
20

170 (125)
- -

106 (78)
117 (86)

(3)

Pulse
As-Welded at 110 kJ/in with 95% Ar/5% CO2
CV
As-Welded at 110 kJ/in with 95% Ar/5% CO2
As-Welded at 45 kJ/in with 95% Ar/5% CO2

TYPICAL OPERATING PROCEDURES


Diameter, Polarity
Shielding Gas

CTWD(5)
mm (in)

Wire Feed Speed


m/min (in/min)

Voltage
(volts)

Approx. Current
(amps)

Melt-Off Rate
kg/hr (lb/hr)

Short Circuit Transfer


90% Ar/25% CO2

9-12
(3/8-1/2)

2.5 (100)
3.8 (150)
6.4 (250)

18
19
22

80
120
175

0.7 (1.6)
1.1 (2.4)
1.8 (4.0)

Spray Transfer
90% Ar/10% CO2

9-12
(3/8-1/2)

9.5 (375)
12.7 (500)
15.2 (600)

23
29
30

195
230
275

2.7 (6.0)
3.6 (8.0)
4.4 (9.6)

Pulsed Spray Transfer(5)

12-19
(1/2-3/4)

5.1 (200)
6.4 (250)

19-21
20-23

130
140

2.4 (5.4)
3.0 (6.7)

Spray Transfer
98% Ar/2% O2
95% Ar/5% CO2

12-19
(1/2-3/4)

8.9 (350)
12.1 (475)
12.7 (500)

27
30
30

285
335
340

4.2 (9.2)
5.7 (12.5)
6.0 (13.2)

12-25 (1/2-1)
12-25 (1/2-1)

5.3 (210)
6.0 (235)
7.4 (290)

25
27
28

325
350
430

4.8 (10.7)
5.4 (12.0)
6.7 (14.8)

0.035 in (0.9 mm), DC+

0.045 in (1.1 mm), DC+

0.052 in (1.3 mm), DC+


Spray Transfer
98% Ar/2% O2
95% Ar/5% CO2

Typical all weld metal. (2)Measured with 0.2% offset. (3)See test results disclaimer on pg. 18. (4)CTWD (Contact Tip to Work Distance). Subtract 1/4 in (6.4 mm) to calculate Electrical Stickout.
Procedures in this area are for pulse MIG mode for welding in the vertical up and overhead welding positions. Actual results are dependent on joint, material thickness, as well as wave shape and pulse frequency.

(1)
(5)

W E L D I N G C O N S U M A B L E S C ATA L O G

67

You might also like