Professional Documents
Culture Documents
Plate Heat Exchangers (PHE) KLP 1
Plate Heat Exchangers (PHE) KLP 1
T = 120
t (waktu)
25.41 menit
No
skala
1
2
3
4
5
100
200
300
400
500
t1 (C)
116.5
117
118
119
120
t(waktu)
27.1
menit
No
skala
1
2
3
100
200
300
fluida dingin
t1 (F)
t2 (C)
241.7
46
242.6
48
244.4
49
246.2
49
248
50
fluida panas
t2 (F)
114.8
118.4
120.2
120.2
122
T steam(C)
119.9
120.7
121.2
122.1
123.3
2. T = 130
t1 (C)
118
121
123
fluida dingin
t1 (F)
t2 (C)
244.4
43
249.8
45
253.4
47
fluida panas
t2(F)
109.4
113
116.6
T steam(C)
129.7
132.2
136.1
fluida panas
T steam(F) T kon(C)
247.82
82
249.26
88
250.16
89
251.78
90
253.94
92
T kon(F)
179.6
190.4
192.2
194
197.6
Bobot kondensat
Kg
24.26
m
(mL/s)
132
105
78
51
25
fluida dingin
m
(lb/jam)
1047.64
833.35
619.06
404.77
198.42
fluida dingin
fluida panas
T steam (F) T kon (C)
265.46
90
269.96
92
276.98
95
T kon (F)
194
197.6
203
Bobot kondensat
Kg
23.44
m
(mL/s)
132
105
78
m
(lb/jam)
1047.64
833.35
619.06
fluida dingin
t rata-rata
Cp rata-rata
(F)
(Btu/lb.F)
178.3
1.09
180.5
1.1
182.3
1.11
183.2
1.12
185.0
1.13
fluida panas
t
(F)
126.9
124.2
124.2
126
126
Q dingin
(Btu/jam)
144910.2
113851.9
85344.6
57121.0
28250.5
hf
(Btu/lb)
216.16
217.80
218.74
220.38
222.61
hg
(Btu/lb)
1163.28
1163.76
1164.06
1164.62
1165.35
hfg ()
(Btu/lb)
947.12
945.96
945.31
944.24
942.73
aktual
berat
kondensat (lb)
waktu (jam)
m (lb/jam)
fluida dingin
t rata-rata
Cp rata-rata
(F)
(Btu/lb.F)
176.9
1.06
181.4
1.08
185.0
1.13
53.48
0.4235
126.291
fluida panas
t
(F)
135
136.8
136.8
Q dingin
(Btu/jam)
149916.8
123122.1
95696.5
hf
(Btu/lb)
234.32
238.91
246.09
hg
(Btu/lb)
1169.22
1170.72
1173.04
hfg ()
(Btu/lb)
934.90
931.81
926.96
aktual
berat
kondensat (lb)
waktu (jam)
m (lb/jam)
51.68
0.45166667
114.413
fluida panas
t rata-rata
cP rata-rata
(F)
Btu/lb.F
213.71
0.45
219.83
0.453
221.18
0.458
222.89
0.459
225.77
0.46
T
(F)
68.22
58.86
57.96
57.78
56.34
M
-Cp*T
Btu/lb
(lb/jam)
916.42
158.13
919.29
123.85
918.77
92.89
917.72
62.24
916.82
30.81
total M teoritis 467.92
% eror
73.01
P (ft)
L (ft)
N
A (ft2)
fluida panas
t rata-rata
Cp rata-rata
(F)
Btu/lb.F
229.73
0.458
233.78
0.46
239.99
0.461
T
(F)
71.46
72.36
73.98
Q panas
Btu/lb.jam
902.17
898.53
892.85
total m teoritis
% eror
1.633858
0.410105
11
7.370588
70.92
78.66
77.76
79.38
81.54
2.14
2.51
2.49
2.52
2.62
0.76
0.92
0.91
0.92
0.96
3.10
3.01
3.18
1.13
1.10
1.16
49.8
12.5
m
(lb)
166.17
137.03
107.18
410.38
72.12
105.66
104.76
109.98
(F)
Btu/jam.ft2.F
93.10
211.175
85.59
180.477
85.25
135.825
85.86
90.262
84.73
45.236
250.000
200.000
U (Btu/jam.Ft2.F)
LMTD
150.000
100.000
50.000
0.000
50
100
150
200
250
skala laju alir
LMTD
(F)
Btu/jam.ft2.F
93.48
217.576
95.16
175.545
95.01
136.654
250.000
U (Btu/jam.Ft2.F)
200.000
150.000
100.000
50.000
0.000
50
100
150
0.000
50
100
150
nilai U
300
skala laju alir
350
400
450
500
550
nilai U
150
200
250
300
350
150
200
skala laju alir
250
300
350