HSDB 990 Firmware Upgrade Procedure: Step 1
HSDB 990 Firmware Upgrade Procedure: Step 1
STEP 1
If you use the pickit as loader,
di-solder n3 jumpers (J5-J4-J3)
do not di-solder the Jump J6
JUMPER
J5 - J4 -J3
Page 1
HSDB 990
+24VDC
GND
Pin 12
Pin 11
STEP 2
Connect the pickit to connector (J1) using an interface cable .
Please verify that the pin-out of the cable result as follows
Connector type:
Female 5 way stripe pitch 2,54
or. AMP Modu II
Pin5)
Pin4)
Pin3)
Pin2)
Pin1)
GND
VDD
MCCR/VPP
PGD
PGC
Connector type:
Male 5 way stripe
pitch 2,54
PGC Pin5)
PGD Pin4)
GND Pin3)
VDD Pin2)
MCCR/VPP Pin 1)
Pin1)
Pin1)
STEP 3
Before loading the Firmware, be sure that the board is
powered (24 VDC-pin12 GND-pin11)
Load the Firmware using the pickit utility
STEP 4
Switch off the board and
restore the jumpers J5-J4-J3 (ri-solder).
Page 2