Download as ppt, pdf, or txt
Download as ppt, pdf, or txt
You are on page 1of 7

POTABLE , UTILITY AND

FIRE WATER SYSTEM


EYE WASH & SAFETY SHOWER

T-1102
POTABLE WATER
TANK

POLYPROPYLENE PLANT

INCINERATOR
(to page8)

W/SHOP, LAB, SAFETY AND


ADMIN. BUILDING

Supply
from
JBA water
WATER
JBA
UTILITY WATER SYSTEM
( to page 2)

T-1101A/B
UTILITY AND FIRE
WATER TANK

COOLING WATER SYSTEM


( to page 3)

FIRE WATER SYSTEM


( to page 4)

DEMINERALIZER SYSTEM
( to page 5)

page 1

UTILITY WATER SYSTEM

Seal Pots in area 600


Area 600

Utility Station
Fire Water Tank
T-1101A/B
from page 1

Propylene
Plant

CPI
U-1401

Area 100 /
300

Area 200

Flare Area
(to page 11)

D-1304

D-1307

D-1308

page 2

COOLING WATER SYSTEM

COOLING WATER SUPPLY

T-1101A/B
UTILITY AND
FIRE WATER
TANK

COOLING
TOWER

COOLING WATER
USERS

(from page 1)
Microbiological control
Sodium Hypochloride &
Spectrus TM NX1101

Backwash

COOLING WATER RETURN

Scale & Deposit Inhibitor


PY 5204 (GE-BETZ)

Corrosion Inhibitor
DN 2760 (GE-BETZ)

Moonson
Drain

SIDE STREAM
FILTER

PPM Cooling Tower


MOONSON DRAIN

page 3

FIRE WATER SYSTEM

Fire Hydrant
Sprinkler System
T-1101A/B
UTILITY AND
FIRE WATER
TANK
(from page 1)

FIRE WATER PUMPS


PC1106,PC1105A/B/C

Deluge System
Foam System
Hose Reel
Cooling Tower

Moonson Drain

page 4

DEMINERALIZER SYSTEM

CO2 to Atm

Activated
Carbon Filter

Cation
Exchanger

Anion
Exchanger

Decarbonator

Deaerator &
Steam Generation
System

Demineralized
Water Tank

(from page 1)

Drain

Drain

(to page 6)
Sampling

T-1101A/B
FIRE WATER TANK
UTILITY
AND
FIRE WATER
TANK

4% NaOH
Moonson Drain

Diversion Sump
Area 400-Q1408

4% HCl

PPM

Heater

Area 100

Steam

Area 200

Regen. outlet
Demineralized water
30% HCl

Cooler

Truck Unloading

30% HCl
D-1107

30% HCl

10% NaOH

T-1107
Neutralization
Tank

10 % NaOH
T-1104

CWS

CWR

50 % NaOH
D-1108

Truck Unloading

Spent Caustic
Neutralization Drum
D-1401

Moonson Drain

D-1402
Area 200

Caustic Scrubber
C-103 Area 100

Spent Caustic
Neutralization Drum
D-1401

page 5

DEAERATOR & STEAM GENERATION SYSTEM


Condensate return

Condensate
Flash Drum
D1005
Demineralized
Water Tank
T-1106A/B

Boilers
B1001/2/3

Deaerator
D1006

(from page 5 )

Diversion Sump
Q1408

Hydrazine

(to page 7)

Corrosion
Inhibitor Tank
U-1001

Ammonium Hydroxide

Neutralizing
Amine Tank
U-1002
Phosphate

Phosphate

Combustion Air

Fuel Gas

(KB-1001/2/3)

(from page 14)

Scale Inhibitor
Tank
U-1003

Corrosion
Inhibitor Tank
U-0202

Steam Users

Waste Heat
Boiler B-1004 &
D-0218

Waste Heat from KC-0201 & Oleflex


Heaters
Area 200

page 6

WASTEWATER TREATMENT SYSTEM`


Incinerator
(from page 8)

Polypropylene
Plant Wastewater

Aerobic
Pond

Recovered Oil to
offsite disposal

Vent to Flare

Slope Oil
Tank

overflow to Q1404

Butamer Unit
Spent Caustic
Storm water
Chemicals
spillage

Acid / Caustic
spillage/overflow

Acid/Caustic Drain
Sump
Q-1101

Effluent
Filterb/wash
Sump -Q1403

Corrugated
Plate
Interceptor

Acid Drain Sump


Q-1103

Storm water

Facultative
Pond

Nutrient Addition

Spent Caustic
Neutralization
Drum
D1401

b/washed
water

Effluent
Filters

Parshall Flume

Flare Oil water


Sump -Q1413
(from page 11)

Diversion Sump
Area 400-Q1408

Outfall
Lab. Drain Sump
Q-1412
30 % HCl
Flushed sample(MTBE)

overflow
Spillage

10 % Caustic

Heavies Tank
T1603
(from page 9)

water from seal pots


Storm water

Diversion Sump
Area 600-Q1405

Diversion Sump
Area 300-Q1406

Diversion Sump
Area 100-Q1407

Diversion Sump
Area 200-Q1409

Diversion Sump
Area 540-Q1404

Diversion Sump
Area 800-Q1410

Diversion Sump
w/shop -Q1411

page 7