Download as ppt, pdf, or txt
Download as ppt, pdf, or txt
You are on page 1of 104

CBB_A04_E1

OMC Radio Parameters Introduction

ZTE University
CDMA-BSS Course Team

Main Content

BSS Parameters
BTS Parameters
Cell Parameters

Carrier Parameters
Channel Parameters

BSS Parameter

BSS Parameters

Forward Power Control Parameters

1X Forward Power Control


Parameters

Reverse Power Control Parameters

BSS Neighbor Cell

BSC Handoff Parameters

Gain Parameters

RLP Parameters

PTT SCH Parameters

Pay Phone Parameters

Special Number Parameters

Switch Parameters

There are twelve parameter tables in BSS grade.

BSS Parameters

BSS Parameters

MSC ID
Description :Switch ID.
Service provider specifies this parameter. The first 16 digits represent Market

ID. The last 8 digits represent the Switch number.


Value Range: 0 ~ 255.

Setting: Network operator maintains this parameter. It is unchangeable at

background.

MS MCC :Mobile Country Code


Value Range: 000~999
Default: 460
Description: It is the first three digits of the International Mobile Station Identity

(IMSI).
China = 460, USA = 310, Canada =302a, Singapore = 525.

BSS Parameters

MS MNC: Mobile Network Code


Value Range: 00~99
Default: 03
Description: part of the IMSI.

MS IMSI_11_12
Value Range: 00~99

IMSI Structure

Default: 03
Description: the eleventh and twelfth digits of the IIMSI, when IMSI is 15 digitals

in lengthIMSI_11_12 is equal to MNC.

An IMSI that is 15 digits in length is called a class0 IMSI (the NMSI is 12


digits in length); an IMSI that is less than 15 digits in length is called a
class 1 IMSI (the NMSI is less than 12 digits in length).

BSS Parameters

BSS Parameters

Intercurrent Voice and data supported indicator


Value Range: 0, 1
Default: 0
Description: Indication of BS concurrent service being

supported.

Packet data services zone id (Data service)


Value Range: 0 255
Default: 1
Description: If the base station supports a packet data

service zone, the base station shall set this field to its
non-zero packet data services zone identifier. If the
base station does not support a packet data service
zone, the base station shall set this field to 0.

BSS Parameters

Soft leg supported number


Value Range: 1~6
Default: 4
Description: If soft leg supported number is too high,

CE resource is wasted, and forward capacity is reduced.


If soft leg supported number is too low, useful pilots
cannot be added into active set. Service quality
declines. Reverse interference increases. But CE
resource and forward capacity is saved.

BSS Parameter

BSS Parameters

Forward Power Control Parameters

1X Forward Power Control Parameters

Reverse Power Control Parameters

BSS Neighbor Cell

BSC Handoff Parameters

Gain Parameters

RLP Parameters

PTT SCH Parameters

Pay Phone Parameters

Special Number Parameters

Switch Parameters

Forward Power Control Parameters

This is for CSM1500

BSS Parameter

BSS Parameters

Forward Power Control Parameters

1X Forward Power Control Parameters

Reverse Power Control Parameters

BSS Neighbor Cell

BSC Handoff Parameters

Gain Parameters

RLP Parameters

PTT SCH Parameters

Pay Phone Parameters

Special Number Parameters

Switch Parameters

1X Forward Power Control Parameters

1X Forward Power Control Parameters

MS Power control step size1/2/3


Value Range: 0~2

Default: MS Power control step size 1:0


MS Power control step size 2:1
MS Power control step size 3:2

Description: Step length of reverse close loop power control (1 leg, 2

or more legs). In terms of power control bits in power control


subchannel, MS adjusts transmission power according to this step
length.

BSS Parameter

BSS Parameters

Forward Power Control Parameters

1X Forward Power Control Parameters

Reverse Power Control Parameters

BSS Neighbor Cell

BSC Handoff Parameters

Gain Parameters

RLP Parameters

PTT SCH Parameters

Pay Phone Parameters

Special Number Parameters

Switch Parameters

Reverse Power Control Parameters

This is for reverse closed


Power control setpoint
For example:
13000: 21-13=8 dB

BSS Parameter

BSS Parameters

Forward Power Control Parameters

1X Forward Power Control Parameters

Reverse Power Control Parameters

BSS Neighbor Cell

BSC Handoff Parameters

Gain Parameters

RLP Parameters

PTT SCH Parameters

Pay Phone Parameters

Special Number Parameters

Switch Parameters

BSS Neighbor cell

BSS Neighbor cell


Press here, system will
jump this windows.

Neighbor cell parameters

Global neighbor cell ID

Value Range: 0~1023


Default: Description: Global neighbor cell Id is generated by background
automatically. It is unchangeable.

Global neighbor cell type


Value Range: 0,1

Default: Description: There is or there isnt relationship between BSC of local

cell and BSC of neighbour cell. Not Protocol Filed.

Neighbor cell parameters

CI Discriminator: Neighbor cell discrimination mode.


Value Range: 1,2,5,7

Default: 2
Description: Not Protocol Filed.

Neighbor cell parameters

MarketId: (A unique market identity provided by a


service provider )
Value Range: 0~65535
Default: Description: When the CI Discriminator isnt 7,

Location, Market Id and Switch Number are inactivated.

SwitchNumber
Value Range: 0~255
Default: Description: used to uniquely identify a special

switching center in a group of switching centers under


the same Market ID. when CI_Discriminator equals to 7,
SwitchNumber is valid and used to construct MSCID.

BSS Parameter

BSS Parameters

Forward Power Control Parameters

1X Forward Power Control Parameters

Reverse Power Control Parameters

BSS Neighbor Cell

BSC Handoff Parameters

Gain Parameters

RLP Parameters

PTT SCH Parameters

Pay Phone Parameters

Special Number Parameters

Switch Parameters

BSC Handoff Parameters

BSC Handoff Parameters

Hard handoff support RC3 and up indicator .


Value Range: 0,1
Default: 1

Description: Indication of 1X hard handoff being

supported. If not support, the MS of RC3 or above are


treated as IS-95 MS. This parameter is used in hard
handoff with disconnected BSC.

BSC Handoff Parameters

Parameters as Search window are default .


Value Range: 0,1
Default: 0
Description: Indication of set the parameters such as

search window and etc. in default. This parameter is


used in hard handoff with disconnected BSC.

BSC Handoff Parameters

SOWD and TOWD include hardware delay


Value Range: 0,1
Default: 1

Description: SOWD and TOWD contain hardware delay

indication. This parameter is used in the hard handoff


with disconnected BSC.

BSS Parameter

BSS Parameters

Forward Power Control Parameters

1X Forward Power Control Parameters

Reverse Power Control Parameters

BSS Neighbor Cell

BSC Handoff Parameters

Gain Parameters

RLP Parameters

PTT SCH Parameters

Pay Phone Parameters

Special Number Parameters

Switch Parameters

BSS Parameter

Gain Parameters
RLP Parameters
PTT SCH Parameters
Pay Phone Parameters
Special Number Parameters
Switch Parameters

In the most of the conditions, the default value


is used in these parameter tables.

Main Content

BSS Parameters
BTS Parameters
Cell Parameters

Carrier Parameters
Channel Parameters

BTS Parameters

The parameters
of this table are
used for EV-DO
service!

BTS Parameters

1X Forward Power Control


Parameters/Switch Parameters

Forward power uprise step size(1/2/3 leg)


Value Range: 1 ~ 7. The unit is 0.25dB
Default:

Forward power uprise step size(1 leg) = 4

Forward power uprise step size(2 leg) = 2

Forward power uprise step size(3 leg) = 1

Description: Forward power control uprising step length. If the power

control step length is set too high, the forward quick power control
response time is short, but the stable state power deviation is high. If
the power control step length is set too low, the stable state power

deviation is low, but the forward quick power control response time is
long.

1X Forward Power Control


Parameters/Switch Parameters

Forward power down step size(1/2/3 leg)


Value Range: 1 ~ 7. The unit is 0.25dB
Default:

Forward power down step size(1 leg) = 4

Forward power down step size(2 leg) = 2

Forward power down step size(3 leg) = 1

Description: Forward power control descending step length. If the

power control step length is set too high, the forward quick power
control response time is short, but the stable state power deviation is
high. If the power control step length is set too low, the stable state
power deviation is low, but the forward quick power control response
time is long.

BTS Parameters
The power
assigned by BTS
to a subscriber.

Maximum
Initial

Power
Minimum
These two parameters
decide Maximum
threshold and
Minimum threshold

1X Forward Power Control


Parameters/Switch Parameters

RCC2 FCH initial power (voice)


Value Range: 163~203. The unit is DGU
Default:

179

Description: RC3/4/5 voice service F-FCH initial transmitting power. If

the initial transmitting power is set too high, F-FCH initial transmitting
power is high, and the MS is easier to receive information correctly
(Frame Error Rate is low), but the forward capacity is lowered when
the channel is established. If the initial transmitting power is set too

low, F-FCH initial transmitting power is low, and the MS may receive
wrong information (Frame Error Rate is high), but the forward power
resource is saved.

1X Forward Power Control


Parameters/Switch Parameters

Nominal transmit power for voice (1/2/3 leg)


Value Range: 1~255. The unit is DGU
Default:

Nominal transmit power for voice (1 leg) = 169

Nominal transmit power for voice (2 leg) = 175

Nominal transmit power for voice (3 leg) = 171

Description: Voice service nominal power.

Power region for voice (1/2/3 leg)


Value Range: 1~255. The unit is DGU
Default:

Power region for voice (1 leg) = 80

Power region for voice (2 leg) = 40

Power region for voice (3 leg) = 32

Description: Voice service power variation region.

Main Content

BSS Parameters
BTS Parameters
Cell Parameters

Carrier Parameters
Channel Parameters

Cell Parameter

Cell Parameter

System Parameter

Power Control Reporting Parameter

Handoff Parameter

Reverse Link Overload Parameter

SCH Rate Parameter

Redirect Message Parameters

Link Cell

Neighbor Frequency

ECAM Information Repeat Parameters

Cell Parameter

Cell Parameter

Cell Parameter

System Identification: SID


Value Range: 0~32767
Default: Description: A number uniquely identifying a wireless system.

Network Identification: NID


Value Range: 0~65534
Default: Description: number that uniquely identifies a network within

a cellular system.

Location Area Code: LAC


Value Range: 0~65535
Default: Description:A toll area may include many LACs, different toll

areas have different LACs.

Cell Parameter

Cell Identity : CI

Value Range: 0~65535

Default:-

Description: Each cell has a unique CI.

Pilot PN sequence offset: PILOT_PN

Value Range: 0~511

Unit: 64PN chip

Description: Protocol Field.

Pilot PN sequence offset index increment: PILOT_INC

Value Range: 0~15

Unit: 64PN chip

Default: 4

Description: Protocol Field.

Cell Parameter

Search window size for the Active Set and Candidate Set:
SRCH_WIN_A
Value Range: 0~15
Default:6

Search window size for the Neighbor Set: SRCH_WIN_N


Value Range:0~15
Default:8

Search window size for the Remaining Set: SRCH_WIN_R


Searcher Window Sizes
Value Range: 0 ~15

Default: 0

Cell Parameter

Cell Parameter

System Parameter

Power Control Reporting Parameter

Handoff Parameter

Reverse Link Overload Parameter

SCH Rate Parameter

Redirect Message Parameters

Link Cell

Neighbor Frequency

ECAM Information Repeat Parameters

System Parameter

System Parameter

Registration zone: REG_ZONE

Value Range: 0~4095


Default:0
Description: Register zone refers to the base station group
within a specified system/network. The zone for a BS is
specified in the REG_ZONE field. One MS can be registered
in more than one zone. The unique SID and NID for the zone
can be added through a REG_ZONE. In consideration of
paging by LAC, the REG_ZONE should correspond to LAC .

Number of registration zones to be retained:


TOTAL_ZONES
Value Range: 0~7
Default:2
Description: By sending Total_Zones (the total number of

storable zones in the zone table) field in the system parameter


message, a BTS can control the maximum number of
registered zones of the registered zone table.

Cell Parameter

Cell Parameter

System Parameter

Power Control Reporting Parameter

Handoff Parameter

Reverse Link Overload Parameter

SCH Rate Parameter

Redirect Message Parameters

Link Cell

Neighbor Frequency

ECAM Information Repeat Parameters

Power Control Reporting Parameter

For forward slow power


Control.

Cell Parameter

Cell Parameter

System Parameter

Power Control Reporting Parameter

Handoff Parameter

Reverse Link Overload Parameter

SCH Rate Parameter

Redirect Message Parameters

Link Cell

Neighbor Frequency

ECAM Information Repeat Parameters

Handoff Parameter

IS-95 Soft Handoff algorithm

Handoff Parameters

Pilot detection threshold: T_ADD


Value range: 0 ~ 47 Default: 26
Unit: -0.5db
Description: be used to trigger a mobile station to send a pilot signal

strength measurement message to start the handoff process.

Pilot drop threshold: T_DROP


Value range: 0 ~ 47 Default: 30
Unit: -0.5db
Description: be used to trigger a mobile station to send a pilot signal

strength measurement message to start the handoff drop process.

Active Set versus Candidate Set comparison threshold: T_COMP


Value range: 0 ~ 15 Default: 5
Unit: 0.5dB
Description: be used to control the transfer of pilot signals from the

candidate set to the active set.

Handoff Parameters

Drop timer value: T_TDROP


Value range: 0 ~ 15

Default: 3

Description: If the pilot signal is in the candidate pilot signal set and also if

the time when its strength is less than T_DROP continuously exceeds
T_TDROP, the pilot signal will be transferred to the neighbor pilot signal set.

Time Corresponding to the Configured T_TDROP Value


T_Tdrop

Time (seconds)

T_Tdrop

Time (seconds)

0.1

27

39

10

55

11

79

12

112

13

159

13

14

225

19

15

319

IS-2000 Soft Handoff algorithm

IS-2000 Soft New Parameters

Slope in the inequality criterion for adding or dropping a pilot :


SOFT_SLOPE
Value range: 0 ~ 63 Default: 0
Description: Soft handoff slope .

Unit: -

Intercept in the inequality criterion for adding a pilot to Active Set:


ADD_INTERCEPT
Value range: 0 ~ 63 Default: 26
Unit: -0.5dB
Description: Add soft handoff intercept.

Intercept in the inequality criterion for dropping a pilot from the


Active Set: DROP_INTERCEPT
Value range: 0 ~ 63 Default: 30 Unit: -0.5dB
Description: Drop soft handoff intercept .

Dynamic Add Threshold: [(SOFT_SLOPE/8) 10 log10(PS1) + ADD_INTERCEPT/2]


Dynamic Drop Threshold : [(SOFT_SLOPE/8) 10 log10(PS2) + DROP_INTERCEPT/2]

Cell Parameter

Cell Parameter

System Parameter

Power Control Reporting Parameter

Handoff Parameter

Reverse Link Overload Parameter

SCH Rate Parameter

Redirect Message Parameters

Link Cell

Neighbor Frequency

ECAM Information Repeat


Parameters

Reverse Link Overload Parameter

Reverse Link Overload Parameter

Reverse Power Control Mode:


Value range: 0 ~ 4

Default: 3

Description: Reverse overload control mode.

Reverse Link Overload Parameter

RC2/RC3/RC4/RSCH Correction Factor


Value range: 0 ~ 32767
Unit: 1/1000

Description: The equivalent user mode will calculate the

reverse load via converting all reverse service channels


into 8 K voice R-FCH under RC1. This set of
parameters will convert R-FCH of RC1, RC3 and RC4,
different target FERs and coding mode (volume or
TURBO) R-SCH into the correction factor for 8 K voice
R-FCH under RC1.

Cell Parameter

Cell Parameter

System Parameter

Power Control Reporting Parameter

Handoff Parameter

Reverse Link Overload Parameter

SCH rate Parameter

Redirect Message Parameters

Link Cell

Neighbor Frequency

ECAM Information Repeat Parameters

SCH Rate Parameter

We can control RSCH


rate by setting the
parameters of this table

Cell Parameter

Cell Parameter

System Parameter

Power Control Reporting Parameter

Handoff Parameter

Reverse Link Overload Parameter

SCH Rate Parameter

Redirect Message Parameters

Link Cell

Neighbor Frequency

ECAM Information Repeat Parameters

Redirect Message Parameters

The system uses


these parameters to
control MS how to
select carrier!

Cell Parameter

Cell Parameter

System Parameter

Power Control Reporting Parameter

Handoff Parameter

Reverse Link Overload Parameter

SCH Rate Parameter

Redirect Message Parameters

Link Cell

Neighbor Frequency

ECAM Information Repeat Parameters

Link Cell

Add neighbor PN
According to designing.

Cell Parameter

Cell Parameter

System Parameter

Power Control Reporting Parameter

Handoff Parameter

Reverse Link Overload Parameter

RSCH Rate Parameter

Redirect Message Parameters

Link Cell

Neighbor frequency

ECAM Information Repeat Parameters

Neighbor frequency

Add neighbor PN for


Handoff between carriers.

Cell Parameter

Cell Parameter

System Parameter

Power Control Reporting Parameter

Handoff Parameter

Reverse Link Overload Parameter

RSCH Rate Parameter

Redirect Message Parameters

Link Cell

Neighbor frequency

ECAM Information Repeat Parameters

ECAM Information Repeat Parameters

We can adjust
how to repeat
ECAM here.

Main Content

BSS Parameters
BTS Parameters
Cell Parameters

Carrier Parameters
Channel Parameters

Carrier Parameter

Carrier Parameter

Global Redirect Message Parameters

PTT SCH Power Control Parameters

Neighbor Cell List

Access Parameter

Power Control Message Parameter

Forward Power Overload Parameter

Periodic Pilot Measurement Request Order

Traffic Parameter

Carrier Parameter

Carrier Parameter

We can use these


two parameters
to balance traffic
for multiple
carrier.

Carrier Parameter

QPCH support indicator: QPCH_SUPPORTED


Value range: 0: not supported, 1: supported
Default: 0
Description: QPCH is a new control channel in the 1X

system compared with the IS95 system, which can only


work above RC3.

Nominal transmit power offset


Value range: 0~15, corresponding to 8 -~ 7 (db)

respectively
Default: 0
Description: Nominal transmit power offset, expressed
in binary supplemental code. This parameter and the
parameter Extended nominal transmit power are used
in the open loop power control of reverse links.

Carrier Parameter

For carrier handoff

Carrier Parameter

Carrier Parameter

Global Redirect Message Parameters

PTT SCH Power Control Parameters

Neighbor Cell List

Access Parameter

Power Control Message Parameter

Forward Power Overload Parameter

Periodic Pilot Measurement Request Order

Traffic Parameter

Carrier Parameter

Just default!

Carrier Parameter

Carrier Parameter

Global Redirect Message Parameters

PTT SCH Power Control Parameters

Neighbor Cell List

Access Parameter

Power Control Message Parameter

Forward Power Overload Parameter

Periodic Pilot Measurement Request Order

Traffic Parameter

Neighbor Cell List

Attention the relationship with


The cell neighbor list!
Carrier neighbor<Cell neighbor

Carrier Parameter

Carrier Parameter

Global Redirect Message Parameters

PTT SCH Power Control Parameters

Neighbor Cell List

Access Parameter

Power Control Message Parameter

Forward Power Overload Parameter

Periodic Pilot Measurement Request Order

Traffic Parameter

Access Parameter

Access Parameter

Access Probing
Access Channel
Request Attempt
Sequence MAX_RSP_SEQ
Access Probe
Sequence 1

Sequence 2

Sequence 3

(15max)

System Time

PD

RS

PD =0 for
Response
Message

PD

RS

PD

Request Message ready


for transmission
Access Probe
1+NUM_STEP
(16 max)

Access Procedure
is depending on the
Access parameter .

Access Probe 3

PI
Access Probe

PI

Access Probe

IP
System Time

TA

RT

TA

RT

Select access channel Initial Power

TA

Access Parameter

NUM_STEP, PWR_STEP and INIT_PWR function simultaneously in the


access attempt sequence of an MS.

INIT_PWR :Initial power offset of access


Unit: dB
Value range: -16 ~ 15 Default: 0

PWR_STEP :Power increment


Unit: dB
Value range: 0 ~ 7

Default: 3

NUM_STEP :Number of access trials


Value range: 0 ~ 15

Default: 6

Description: The maximum number of access probe to be transmitted.

Access Parameter

MAX_CAP_SZ
Unit: Frame
Value range: 0 ~ 7
Default: 3
Description: Maximum Access Channel message capsule size. 3 less than

the maximum number of Access Channel frames in an Access Channel


message capsule.

PAM_SZ
Unit: Frame
Value range: 0 ~ 15 Default: 3
Description:Access Channel preamble length. 1 less than the number of

Access Channel frames that mobile stations are to transmit in each Access
Channel preamble.

Access Parameter

PROBE_BKOFF
Value Range: 0~15

Default:0

Description: The next access probe is transmitted after an additional

backoff delay, RT, from 0 to 1+PROBE_BKOFF slots.


RT = 0 ~ [PROBE_BKOFF +1] slots

BKOFF
Value Range: 0~15 Default:0
Description: For every access probe sequence, a backoff delay, RS,

from 0 to 1+BKOFF slots is generated pseudorandomly.


RS = 0 ~ [BKOFF +1] slots

Access Parameter

ACC_TMO
Unit: 80ms
Value Range: 0~15 Default:3
Description:After sending the access probe, The MS shall wait ACK

as much as this time before transmitting next access probe


TA = (2 + ACC_TMO) * 80ms

PROBE_PN_RAN:
Value Range: 0~9 Default:0
Description: Time randomization for access channel probes.To avoid

collision among the MS to try call access at the same time:


PN randomization delay =
(PN chip)

0 ~ 2PROBE_PN_RAN-1

Carrier Parameter

Carrier Parameter

Global Redirect Message Parameters

PTT SCH Power Control Parameters

Neighbor Cell List

Access Parameter

Power Control Message Parameter

Forward Power Overload Parameter

Periodic Pilot Measurement Request Order

Traffic Parameter

Power Control Message Parameter

Power Control Message Parameter

Forward Power Control

Operation Mode Indicator

Value Range: 0~6


Default:0
Description: Indication

of forward power control


operation mode of FFCH where there is no
F-SCH.

Carrier Parameter

Carrier Parameter

Global Redirect Message Parameters

PTT SCH Power Control Parameters

Neighbor Cell List

Access Parameter

Power Control Message Parameter

Forward Power Overload Parameter

Periodic Pilot Measurement Request Order

Traffic Parameter

Forward Power Overload Parameter

Forward Power Overload Parameter

Rating Power: RATING_PWR


Unit: Milliwatt
Value: 0~30000
Description: The parameter refers to the rated power of HPA ,

Provided by network planning .

Cell Power design value: CELL_PWR


Unit: Milliwatt

Value: 0~30000
Description: Designed power of the cell.

Carrier Parameter

Carrier Parameter

Global Redirect Message Parameters

PTT SCH Power Control Parameters

Neighbor Cell List

Access Parameter

Power Control Message Parameter

Forward Power Overload Parameter

Periodic Pilot Measurement Request Order

Traffic Parameter

Periodic Pilot Measurement Request Order

For carrier handoff

Carrier Parameter

Carrier Parameter

Global Redirect Message Parameters

PTT SCH Power Control Parameters

Neighbor Cell List

Access Parameter

Power Control Message Parameter

Forward Power Overload Parameter

Periodic Pilot Measurement Request Order

Traffic Parameter

Traffic Parameter

CE search window

Main Content

BSS Parameters
BTS Parameters
Cell Parameters

Carrier Parameters
Channel Parameters

Channel Parameters

Pilot Channel

Synchronous Channel

Paging Channel

Access Channel

Configuring Pilot Channel

Configuring Pilot Channel

ModuleId
Value range:
Default: 1
Description: Module where the Pliot channel is located,The

parameter has influence upon cell coverage.

ElementId
Value range: 0 ~ 35

Default: 0
Description: Element where the pilot channel is located. The

parameter has influence upon cell coverage.

Pilot channel gain

Unit: (X-255)/4
Value range: 0 ~ 255
Default: 225
Description : Provided by network planning, generally

according to the default value.


Suppose the configuration value is X, the corresponding dB
value is (x-255)/4. For example, if Pilot_gain is set to 225, the
corresponding dB value is (225-255)/4 = -7.5dB.

PilotPower mW CELL _ PWR 10

PILOTCH_G AIN 255


40

The Synchronous Channel, Paging Channel and Access


Channel are similar to this.

You might also like