Download as pdf or txt
Download as pdf or txt
You are on page 1of 24

SANDWICH

PANELS
FOR WALLS
AND ROOFS
BUILDING LIFETIME EFFICIENCY

Ruukki energy panels

Focus on green efficiency.


And save money.
Airtight top technology
The new Ruukki energy panel solution consists of airtight Ruukki energy panels,
structural details, accessories, airtightness instructions and installation services.
Save up to 30% in yearly energy costs
The new energy panel solution creates savings in heating costs, leading in turn
to significantly reduced carbon dioxide emissions generated by the use of the
building. A building that utilizes the energy panel solution will also receive higher
LEED* and BREEAM* credits.
Ruukkis airtightness promise seals the deal
As the only manufacturer, Ruukki is able to promise an exact airtightness level for
a building. The guarantee is agreed upon case-by-case in a separate contract.
Choosing Ruukkis airtight energy panel solution will increase the value of
your property.
* Voluntary certificates assessing the environmental impact of a building

www.ruukki.com/sandwichpanels

Sandwich panels for walls and roofs

One panel many options


for customer buildings
Ruukki sandwich panel comes in different core
materials (PU, PIR, W and S) and thicknesses, various profiling shapes and coatings, many standard
and non-standard colours, as well as options for the
vertical or horizontal installation of wall panels.
All this gives our customers freedom to choose the
wall and roof cladding they want according to their
project requirements.
Comprehensive panel system
delivery and much more
Ruukki, as one of only a few sandwich panel producers, can provide a customer with a total panel
package starting from design tailored to the
customers needs, through selection of the right
panel type, freedom of choosing a range of product
features and specifying essential accessories to a
speedy and efficient installation service.
Safety - first and foremost
Ruukki sandwich panels offer excellent fire safety
properties, especially the panels with a mineral wool
core, which boast exceptional fire safety properties,
as well as acoustic insulation. The most recent
Ruukkis achievement: our PIR wall sandwich panels
have EI 30/EW 60 ratings, one of the best results in
terms of fire safety in the European market!
Time-constant thermal insulation
Ruukki panels provide excellent thermal insulation.
Air-tight cladding reduces the maintenance costs of
a building, such as heating, cooling and air conditioning, and consequently the release of CO2 into
the atmosphere.
For a building to last
Ruukki panels, thanks to their high quality core and
cladding materials, and innovative glueing system,
boast excellent durability, corrosion resistance,
thermal insulation and mechanical properties. Our
calculated strength tables allow the quick and easy
selection of panels suitable for a particular building. With Ruukki panels even dark colours can be
successfully used. Our panels as first on the market
have achieved the highest atmospheric-corrosivity
category C5-M. With our panels customers buildings
will live longer.

New energy panel solution ENERGY


The main advantage of new energy panels is
their higher airtightness and thermal insulation comparing to traditional sandwich panels.
High class joint tightness is achieved thanks
to the use of special ENERGY gasket and
production process with minimal engineering
tolerances.
Special attention is also paid to production
quality control in order to achieve superior
airtightness up to passive house standard.
New energy panels are offered in three airtightness classes defined as Basic, Plus and Premium
levels. Ruukki energy panels are the basis of Plus
and Premium levels, for which air leakage figures
are respectively n50 0,9 l/h and n50 0,6 l/h.
For these two levels Ruukki gives a promise that
specified values will not be exceeded. In case of
Basic level, Ruukkis traditional sandwich panels
are used and air leakage figure is n50 1,3 l/h.

New group of sandwich panels


with mineral wool core
Increasingly stricter requirements as to thermal
insulation of buildings force construction material manufacturers to search for new solutions
and focus on further improvement of their
products.
In order to meet these requirements and to fulfill
our customers expectations we developed a new
offer of sandwich panels with the core made of
mineral wool - SP2D WE and SPB WE. These new
panels feature a core with lower density. The
cores physical and mechanical properties ensure
proper strength, what is reflected in relevant
strength tables.
Very low thermal conductivity allows to improve significantly thermal parameters of walls
made with the use of new sandwich panels.
New panels with mineral wool core are a perfect
solution for envelopes that must meet high
requirements as to energy efficiency.

Ruukki SPF PU

Ruukki SP2D PU

core

rigid polyurethane
foam

rigid polyurethane
foam

thickness
[mm]

98 / 80

60

80

100

weight
[kg/m2]

15.3

10.3

11.0

11.7

value

Ruukki SPF PU
1. Large bend radii on facings ensure that none of the protective coat
properties is lost.
2. Facing profiling ensures uniform facade appearance.
3. Double lock from outer and inner sides increases fire-tightness and facilitates assembly.
4. Properly profiled edges improve thermal insulation and joint tightness.
5. Auxiliary groove allows for precise assembly.
6. Concealed panel fixings ensure aesthetic facade appearance.
7. Rigid, HCFC-free, self-extinguishing, environmentally and ozone friendly
polyurethane foam core provides excellent thermal insulation parameters.
8. Continuous polyurethane seal ensures proper thermal insulation and
joint tightness.
9. Aluminium foil prevents gas diffusion and penetration of vapour into
a polyurethane core (constant thermal parameters of panels).
10. Narrow, almost invisible 1 mm gap.

[W/mK]

0.022

U value
[W/m2K]4

0.23

reaction to fire

B-s3, d0

sound
insulation [dB]

25

0.022
0.35

0.26

0.21

B-s2,d0
24
18,5

maximum length
[m]

18.5

18.5

total width
[mm]

963.5

1050

modular width
[mm]

900

1000

external facing
thickness [mm]

0.60

0.50

internal facing
thickness [mm]

0.55

0.40

certificates
and approvals

Declaration of conformity
CE acc. to EN 14509
Hygienic Certificate
HC/97/779/104/2011

Declaration of conformity
CE acc. to EN 14509
Hygienic Certificate
HC/97/779/104/2011

external facing
profiling

S sinusoidal

R28 ribbed
L linear
P embossed
F flat1
M microprofiled

internal facing
profiling

L linear
F flat1

L linear
F flat1

possible
profiling
combinations

SL, SF

RL, RF, PL, PF,


ML, MF, LL, LF,
FL, FF

standard colours of
external facing
RAL5

9006

1015, 3013, 5005, 6011,


7016, 7035, 9002, 9006,
9007, 9010

standard colours of
internal facing
RAL

9010

9002, 9010

other colours

see point2

see point2

Ruukki SP2D PU
1. Large bend radii on facings ensure that none of the protective coat
properties is lost.
2. Facing profiling ensures uniform facade appearance.
3. Double lock from outer and inner sides increases fire-tightness and
facilitates assembly.
4. Rigid, HCFC-free, self-extinguishing, environmentally and ozone friendly
polyurethane foam core provides excellent thermal insulation parameters.
5. Auxiliary groove allows for precise assembly.
6. Concealed panel fixings ensure aesthetic facade appearance.
7. Properly profiled edges improve thermal insulation and joint tightness.
8. Continuous polyurethane seal ensures proper thermal insulation and
joint tightness.
9. Aluminium foil prevents gas diffusion and penetration of vapour into
a polyurethane core (constant thermal parameters of panels).
10. Gas permeable polyurethane seal.

1 the surface of plain profile can be slightly corrugated min. facing thickness 0.50 mm.
2 other colours according to RAL system, available on special order, following additional arrangements. External

panel facings in dark colours (from standard colour range RAL 3013, 5005, 7016 and 9007), due to considerable
thermal loads, higher than that of lighter colours, can be deformed. In order to minimize this phenomenon, it
is advisable to apply only single-span systems for wall panels; for roof panels limitation to maximal lengths
resulting from calculations that take into cosideration thermal loads; in doubtful cases please consult construction department of panels producer.

Sandwich panels for walls and roofs

Ruukki SP2B PU

Ruukki SP2E PU

rigid polyurethane
foam

rigid polyurethane
foam

core

40

60

80

100

120

160

180

200

thickness
[mm]

8.4

9.1

9.9

10.6

11.9

13.4

14.1

14.8

weight
[kg/m2]

0.50

0.35 0.26

value

0.021

0.022

[W/mK]

(temp. 0C)

0.21

0.17

0.13

0.11

0.10

U value
[W/m2K]4

B-s2,d0

B-s2, d0

reaction to fire

24

25

sound
insulation [dB]

18.5

18.5

maximum length
[m]

1120

1120

total width
[mm]

1100

1100

modular width
[mm]

0.50

0.50

external facing
thickness [mm]

0.40

0.50

internal facing
thickness [mm]

Declaration of conformity
CE acc. to EN 14509
Hygienic Certificate
HC/97/779/104/2011

Declaration of conformity
CE acc. to EN 14509
Hygienic Certificate
HC/97/779/104/2011

certificates
and approvals

R28 ribbed
L linear
P embossed
F flat1
M microprofiled

R28 ribbed
L linear
P embossed
F flat1
M microprofiled

L linear
F flat1

L linear
F flat1

RL, RF, PL, PF,


ML, MF, LL, LF,
FF3

RL, RF, PL, PF,


ML, MF, LL, LF,
FF3

1. Large bend radii on facings ensure that none of the protective coat
properties is lost.
2. Facing profiling ensures uniform facade appearance.
3. Double lock from outer and inner sides increases fire-tightness and facilitates assembly.
4. 3 mm gap enables to meet sanitary and hygienic requirements (food,
cooling, pharmaceutical industries etc.).
5. Properly profiled edges improve thermal insulation parameters and joint
tightness.
6. Rigid, HCFC-free, self-extinguishing, environmentally and ozone friendly
polyurethane foam core provides excellent thermal insulation parameters.
7. Aluminium foil prevents gas diffusion and penetration of vapour into
a polyurethane core (continuous thermal parameters of panels).
8. Continuous polyurethane seal ensures thermal insulation and joint
tightness.

external facing
profiling

internal facing
profiling
possible
profiling
combinations

1015, 3013, 5005, 6011,


7016, 7035, 9002, 9006,
9007, 9010

1015, 3013, 5005, 7035,


9002, 9006, 9007,
9010

standard colours of
external facing
RAL5

9002, 9010

9002, 9010

standard colours of
internal facing
RAL

see point2

see point2

other colours

3 only for partition walls.


4 U value includes impact of linear thermal bridge appearing on panel joint.
5 Facing colour groups is in the table on page 19.

Ruukki SP2B PU

Ruukki SP2E PU
1. Large bend radii on facings ensure that none of the protective coat
properties is lost.
2. 3 mm gap enables additional joint closure with durably elastic mass (p.8).
3. Precisely milled labyrinth core edge eliminates thermal bridges.
4. Double lock from outer and inner sides increases fire-tightness and
facilitates assembly.
5. Butyl sealing compound eliminates air and moisture penetration, applied at
building site.
6. Facing profile conforming with the standards applicable to cooling and food
industries ensures uniform facade appearance.
7. Rigid, HCFC-free and self-extinguishing environmentally and ozone friendly
polyurethane foam core of excellent thermal insulation.
8. Durably elastic sealing compound (compulsory for ceilings, optional for walls),
applied at building site.

Ruukki SP2C PU

Ruukki SP2D PIR

core

rigid polyurethane
foam

rigid polyisocyanurate foam

thickness
[mm]

80/40 100/60 120/80 140/100 160/120 210/170

weight
[kg/m2]

9.5

10.3

value

Ruukki SP2C PU
1. Large bend radii on facings ensure that none of the protective coat properties is lost.
2. Facing profiling ensures uniform facade appearance.
3. Rigid, HCFC-free, self-extinguishing, environmentally and ozone friendly
polyurethane foam core provides excellent thermal insulation parameters.
4. Aluminium foil prevents gas diffusion and the penetration of vapour
into a polyurethane core (continuous thermal parameters of panels).
5. Auxiliary groove allows for precise assembly.
6. Properly profiled edges improve thermal insulation and joint tightness.
7. Specially shaped micro-chamber protects against water capillary penetration.
8. Continuous polyurethane seal ensures thermal insulation and joint
tightness.

11.7

12.5

14.3

80

100

10.4

11.2

12.0

0.022

[W/mK]

U value
[W/m2K]4

11.0

60

0.46

0.31

0.24

0.20

0.021
0.17

0.13

0.34

0.25 0.20

reaction to fire

B-s2,d0

60-80 B-s2,d0
100 B-s1,d0

external fire
exposure

BROOF (t1)

sound
insulation [dB]

24

24

maximum length
[m]

18.54

18.5

total width
[mm]

1083

1050

modular width
[mm]

1000

1000

external facing
thickness [mm]

0.50

0.50 or 0,60

internal facing
thickness [mm]

0.40

0.40

certificates
and approvals

Declaration of conformity
CE acc. to EN 14509
Hygienic Certificate
HC/97/779/104/2011

Declaration of conformity CE acc. to EN


14509
Hygienic
Certificate
HC/97/779/104/2011

external facing
profiling

T trapezoidal

R28 ribbed
L linear
P embossed
F flat1
M microprofiled

internal facing
profiling

L linear
F flat1

possible
profiling
combinations

TL, TF

RL, RF, PL, PF,


ML, MF, LL, LF,
FL, FF

standard colours of
external facing
RAL6

1015, 3013, 5005,


6011, 7035, 9002,
9006, 9010

1015, 3013, 5005,


6011, 7035, 9002,
9006, 9007, 9010

standard colours of
internal facing
RAL

9002, 9010

9002, 9010

other colours

see point2

see point2

L linear
F flat1

Ruukki SP2D PIR


1. Large bend radii on facings ensure that none of the protective coat
properties is lost.
2. Facing profiling ensures uniform facade appearance.
3. Double lock from outer and inner sides increases fire-tightness and
facilitates assembly.
4. Rigid, HCFC-free, self-extinguishing, environmentally and ozone friendly
polyisocyanurate foam core provides excellent fire insulation parameters.
5. Auxiliary groove allows for precise assembly.
6. Concealed panel fixings ensure aesthetic facade appearance.
7. Properly profiled edges improve thermal insulation and joint tightness.
8. Continuous polyurethane seal ensures proper thermal insulation and
joint tightness.
9. Aluminium foil prevents gas diffusion and penetration of vapour into
a polyurethane core (constant thermal parameters of panels).
10. Gas permeable polyurethane seal.

1 the surface of plain profile can be slightly corrugated min. facing thickness 0.50 mm.
2 other colours according to RAL system, available on special order, following additional arrangements. External

panel facings in dark colours (from standard colour range RAL 3013, 5005, 7016 and 9007), due to considerable
thermal loads, higher than that of lighter colours, can be deformed. In order to minimize this phenomenon, it
is advisable to apply only single-span systems for wall panels; for roof panels limitation to maximal lengths
resulting from calculations that take into cosideration thermal loads; in doubtful cases please consult construction department of panels producer.

Sandwich panels for walls and roofs

Ruukki SP2B PIR

Ruukki SP2E PIR

rigid polyisocyanurate
foam

rigid polyisocyanurate
foam

core

40

60

80

100

120

160

180

200

thickness
[mm]

8.5

9.3

10.1

10.9

12.4

14.0

14.8

15.6

weight
[kg/m2]

0.49

0.34

0.25

value

0.020

0.021

[W/mK]

(temp. 0C)

0.20

40-80 B-s2,d0
100 B-s1,d0

0.16

0.12

0.11

0.10

U value
[W/m2K]4

B-s1,d0

reaction to fire

external fire
exposure

24

25

sound
insulation [dB]

18.5

18.5

maximum length
[m]

1120

1120

total width
[mm]

1100

1100

modular width
[mm]

0.50 or 0.60

0,50 or 0.60

external facing
thickness [mm]

0.40

0.50

internal facing
thickness [mm]

Declaration of conformity
CE acc. to EN 14509
Hygienic Certificate
HC/97/779/104/2011

Declaration of conformity
CE acc. to EN 14509
Hygienic Certificate
HC/97/779/104/2011

R28 ribbed
L linear
P embossed
F flat1
M microprofiled

R28 ribbed
L linear
F flat1
M microprofiled

external facing
profiling

L linear
F flat1

L linear
F flat1

internal facing
profiling

RL, RF, PL, PF,


ML, MF, LL, LF,
FL, FF3

RL, RF, LL, ML, LF,


MF, FF3

possible
profiling
combinations

1015, 3013, 5005, 6011,


7035, 9002, 9006,
9007, 9010

1015, 3013, 5005, 6011,


7035, 9002, 9006,
9007, 9010

standard colours of
external facing
RAL6

9002, 9010

9002, 9010

standard colours of
internal facing
RAL

see point2

see point2

other colours

3 only for partition walls.


4 on special request up to 21.0 m.
5 U value includes impact of linear thermal bridge appearing on panel joint.
6 Facing colour groups is in the table on page 19.

Ruukki SP2B PIR


1. Large bend radii on facings ensure that none of the protective coat
properties is lost.
2. Facing profiling ensures uniform facade appearance.
3. Double lock from outer and inner sides increases fire-tightness and facilitates assembly.
4. 3 mm gap enables to meet sanitary and hygienic requirements (food,
cooling, pharmaceutical industries etc.).
5. Properly profiled edges improve thermal insulation parameters and joint
tightness.
6. Rigid, HCFC-free, self-extinguishing, environmentally and ozone friendly
polyisocyanurate foam core provides excellent fire insulation parameters.
7. Aluminium foil prevents gas diffusion and penetration of vapour into
a polyurethane core (continuous thermal parameters of panels).
8. Continuous polyurethane seal ensures thermal insulation and joint
tightness.

certificates
and approvals

Ruukki SP2E PIR


1. Large bend radii on facings ensure that none of the protective coat
properties is lost.
2. 3 mm gap enables additional joint closure with durably elastic mass (p.8).
3. Precisely milled labyrinth core edge eliminates thermal bridges.
4. Double lock from outer and inner sides increases fire-tightness and
facilitates assembly.
5. Butyl sealing compound eliminates air and moisture penetration, applied at
building site.
6. Facing profile conforming with the standards applicable to cooling and food
industries ensures uniform facade appearance.
7. Rigid, HCFC-free and self-extinguishing environmentally and ozone friendly
polyisocyanurate foam core of excellent fire insulation.
8. Durably elastic sealing compound (compulsory for ceilings, optional for walls),
applied at building site.

Ruukki SP2C PIR

Ruukki SP2D W

core

rigid polyisocyanurate
foam

hard mineral
wool

thickness
[mm]

80/40 100/60 120/80 140/100 160/120 210/170

weight
[kg/m2]

9.7

10.5

value

Ruukki SP2C PIR


1. Large bend radii on facings ensure that none of the protective coat properties is lost.
2. Facing profiling ensures uniform facade appearance.
3. Rigid, HCFC-free, self-extinguishing, environmentally and ozone friendly
polyisocyanurate foam core provides excellent thermal insulation parameters.
4. Aluminium foil prevents gas diffusion and the penetration of vapour
into a polyurethane core (continuous thermal parameters of panels).
5. Auxiliary groove allows for precise assembly.
6. Properly profiled edges improve thermal insulation and joint tightness.
7. Specially shaped micro-chamber protects against water capillary penetration.
8. Continuous polyurethane seal ensures thermal insulation and joint
tightness.

Ruukki SP2D W
1. Core made of rigid, environmentally friendly mineral wool provides
excellent fire resistance.
2. Properly milled core improves thermal insulation.
3. Large bend radii on facings ensure that none of the protective coat
properties is lost.
4. Facing profiling ensures uniform facade appearance.
5. Double lock from outer and inner sides increases fire-tightness and faci-
litates assembly.
6. Auxiliary groove allows for precise assembly.
7. Concealed panel fixings ensure aesthetic facade appearance.
8. Butyl sealing compound (applied at building site) protects against water
and moisture penetration.

12.1

12.9

14.9

0.021

[W/mK]

U value
[W/m2K]4

11.3

0.46

0.31

0.24 0.20

140 160

100 120

21.5 23.8 26.1 28.3


0.043

0.17

0.13

0.43 0.35 0.31 0.27

reaction to fire

80/40-120/80 B-s2,d0
140/100-210/170 B-s1,d0

A2-s2, d0

external fire
exposure

BROOF (t1)

sound
insulation [dB]

24

32

maximum length
[m]

18.52

12.0 12.0 12.0 10.0

total width
[mm]

1083

1054

modular width
[mm]

1000

1000

external facing
thickness [mm]

0.50

0.60

internal facing
thickness [mm]

0.40

0.50

certificates
and approvals

Declaration of conformity CE
acc. to EN 14509
Hygienic Certificate
HC/97/779/104/2011

Declaration of conformity CE acc.


to EN 14509
Hygienic Certificate
HC/97/779/104/2011

external facing
profiling

T trapezoidal

R28, R250, R500


L linear
M microprofiled

internal facing
profiling

L linear

L linear
F flat

possible
profiling
combinations

TL

RL, ML, LL,


RF, MF, LF

standard colours of
external facing
RAL4

1015, 3013, 5005,


6011, 7035, 9002,
9006, 9010

1015, 5005,
7035, 9002, 9006,
9007, 9010

standard colours of
internal facing
RAL

9002, 9010

9002, 9010

other colours

see point1

see point1

1 other colours according to RAL system, available on special order, following additional arrangements. External

panel facings in dark colours (from standard colour range RAL 3013, 5005, 7016 and 9007), due to considerable
thermal loads, higher than that of lighter colours, can be deformed. In order to minimize this phenomenon, it
is advisable to apply only single-span systems for wall panels; for roof panels limitation to maximal lengths
resulting from calculations that take into cosideration thermal loads; in doubtful cases please consult
construction department of panels producer.

Sandwich panels for walls and roofs

80

Ruukki SPB W

Ruukki SPC W

hard mineral
wool

hard mineral
wool

100

120

18.7 21.0

160

140

200

23.3 25.6 27.9 32.5

140/100

190/150

thickness
[mm]

22.0

27.8

weight
[kg/m2]

0.043

value

0.043

0.51 0.41 0.34 0.30 0.26 0.21

core

0.41

[W/mK]

0.28

U value
[W/m2K]4

A2-s2, d0

A2-s2, d0

reaction to fire

BROOF (t1)

external fire
exposure

32

34

sound
insulation [dB]

12.0

maximum length
[m]

1018 lub 1118

1059

total width
[mm]

1000 lub 1100

1000

modular width
[mm]

0.60

0.60

external facing
thickness [mm]

0.50

0.50

internal facing
thickness [mm]

Declaration of conformity CE acc. to Hygienic


Certificate
HC/97/779/104/2011

Declaration of conformity CE acc. to EN 14509


Hygienic Certificate
HC/97/779/104/2011

R28, R250, R500


(for 1000 mm modular width)
R275, R550 (for 1100 mm
modular width)
L linear, F flat
M microprofiled

T trapezoidal

external facing
profiling

L linear
F flat

L linear
F flat

internal facing
profiling

RL, ML, LL, FL,


RF, MF, LF, FF

TL, TF

possible
profiling
combinations

1015, 5005,
7035, 9002, 9006,
9007, 9010

1015, 5005, 7035,


9002, 9006, 9010

standard colours of
external facing
RAL4

9002, 9010

9002, 9010

standard colours of
internal facing
RAL

see point1

see point1

other colours

8,0

12,0

12,0

10,0

10,0

2 on special request up to 21.0 m.


3 U value includes impact of linear thermal bridge appearing on panel joint.
4 Facing colour groups is in the table on page 19.

Ruukki SPB W
1. Large bend radii on facings ensure that none of the protective coat properties is lost.
2. Facing profiling ensures uniform facade appearance.
3. Double lock from outer and inner sides increases fire-tightness and facilitates assembly.
4. 3 mm gap enables to meet sanitary and hygienic requirements (food,
cooling, pharmaceutical industries, etc.).
5. Butyl sealing compound (applied at building site) protects against water
and moisture penetration.
6. Properly milled core improves thermal insulation and joint tightness.
7. Core made of rigid, environmentally friendly mineral wool provides
excellent fire resistance.

certificates
and approvals

Ruukki SPC W
1. Core made of rigid, environmentally friendly mineral wool provides excel-
lent fire resistance.
2. Hump made of environmentally friendly, hard mineral wool.
3. Properly milled core improves thermal insulation and joint tightness.
4. Large bend radii on facings ensure that none of the protective coat properties is lost.
5. Facing profiling ensures uniform facade appearance.
6. The lock from inner side increases fire-tightness and facilitates assembly.
7. Specially shaped micro-chamber protects against water capillary pene-
tration.
8. Auxiliary groove allows for precise assembly.
9. Butyl sealing compound (applied at building site) protects against water and moisture penetration.

core

soft mineral
wool

120

140

160

weight
[kg/m2]

19.0

20.8

22.6

24.4

U value
[W/m2K]4

soft mineral
wool
100

80

100

120

0.40

0.29

0.33

140

0.25 0.48 0.39 0.32 0.28 0.24 0.20

A2-s1, d0

A2-s1, d0

external fire
exposure

sound
insulation [dB]

29

29

12.0

12.0

12.0

10.0

8.0

12.0

12.0

10.0

10.0

total width
[mm]

1054

1018 or 1118

modular width
[mm]

1000

1000 or 1100

external facing
thickness [mm]

0.60

0.60

internal facing
thickness [mm]

0.50

0.50

Declaration of conformity
CE acc. to EN 14509
Hygienic Certificate
HC/97/779/104/2011

Declaration of conformity CE
acc. to EN 14509
Hygienic Certificate
HC/97/779/104/2011

external facing
profiling

R28, R250, R500,


L linear
M microprofiled

R28, R250, R500


(for 1000 mm modular width)
R275, R550 (for 1100 mm
modular width)
L linear, F flat
M microprofiled

internal facing
profiling

L linear
F flat

L linear
F flat

possible
profiling
combinations

RL, ML, LL,


RF, MF, LF

RL, ML, LL, FL,


RF, MF, LF, FF

standard colours of
external facing
RAL3

1015, 5005, 7035,


9002, 9006,
9007, 9010

1015, 3013, 5005,


7035, 9002, 9006,
9010

standard colours of
internal facing
RAL

9002, 9010

9002, 9010

other colours

see point1

see point1

certificates
and approvals

Ruukki SPB WE
1. Large bend radii on facings ensure that none of the protective coat properties is lost.
2. Facing profiling ensures uniform facade appearance.
3. Double lock from outer and inner sides increases fire-tightness and facilitates assembly.
4. 3 mm gap enables to meet sanitary and hygienic requirements (food,
cooling, pharmaceutical industries, etc.).
5. Butyl sealing compound (applied at building site) protects against water
and moisture penetration.
6. Properly milled core improves thermal insulation and joint tightness.
7. Core made of soft, environmentally friendly mineral wool provides
excellent fire resistance.

200

0.040

reaction to fire

maximum length
[m]

160

16.8 18.6 20.4 22.2 24.0 27.6

0.040

[W/mK]

1. Core made of soft, environmentally friendly mineral wool provides


excellent fire resistance.
2. Properly milled core improves thermal insulation.
3. Large bend radii on facings ensure that none of the protective coat
properties is lost.
4. Facing profiling ensures uniform facade appearance.
5. Double lock from outer and inner sides increases fire-tightness and faci-
litates assembly.
6. Auxiliary groove allows for precise assembly.
7. Concealed panel fixings ensure aesthetic facade appearance.
8. Butyl sealing compound (applied at building site) protects against water
and moisture penetration.

Ruukki SPB WE

thickness
[mm]

value

Ruukki SP2D WE

Ruukki SP2D WE

1 other colours according to RAL system, available on special order, following additional arrangements. External

panel facings in dark colours (from standard colour range RAL 3013, 5005, 7016 and 9007), due to considerable
thermal loads, higher than that of lighter colours, can be deformed. In order to minimize this phenomenon, it is
advisable to apply only single-span systems for wall panels; for roof panels limitation to maximal lengths resulting
from calculations that take into cosideration thermal loads; in doubtful cases please consult construction
department of panels producer.

Sandwich panels for walls and roofs

Ruukki SPB S

Ruukki SPC S

polystyrene

polystyrene

core

60

80

100

140

200

140/100

190/150

thickness
[mm]

9.5

9.8

10.0

10.5

11.0

11.0

12.0

weight
[kg/m2]

0.037
0.58

value

0.037

0.44 0.35 0.24

0.17

0.34

[W/mK]

0.23

U value
[W/m2K]4

B-s2, d0

B-s3, d0

reaction to fire

BROOF (t1)

external fire
exposure

26

sound
insulation [dB]

18.5

maximum length
[m]

1118

1059

total width
[mm]

1100

1000

modular width
[mm]

0.50

0.50

external facing
thickness [mm]

0.50

0.50

internal facing
thickness [mm]

Declaration of conformity CE acc. to EN 14509


Hygienic Certificate
HC/97/779/104/2011

Declaration of conformity CE acc. to EN 14509


Hygienic Certificate
HC/97/779/104/2011

L linear
M microprofiled

T trapezoidal

external facing
profiling

L linear

L linear

internal facing
profiling

LL, ML

TL

possible
profiling
combinations

1015, 6011, 7035,


9002, 9006, 9010

standard colours of
external facing
RAL3

9002, 9010

9002, 9010

standard colours of
internal facing
RAL

see point1

see point1

other colours

24
12.0

1.0

18.5

18.5

18.5

Ruukki SPB S
1. Large bend radii on facings ensure that none of the protective coat properties is lost.
2. Facing profiling ensures uniform facade appearance.
3. Double lock from outer and inner sides increases fire-tightness and facilitates assembly.
4. 3 mm gap enables to meet sanitary and hygienic requirements (food,
cooling, pharmaceutical industries, etc.).
5. Butyl sealing compound (applied at building site) protects against water
and moisture penetration.
6. Properly milled core improves thermal insulation and joint tightness.
7. Core made of environmentally friendly polystyrene.

certificates
and approvals

Ruukki SPC S
1015, 6011, 7035, 9002,
9006, 9010

2 U value includes impact of linear thermal bridge appearing on panel joint.


3 Facing colour groups is in the table on page 19.

1. Large bend radii on facings ensure that none of the protective coat
properties is lost.
2. Facing profiling ensures uniform facade appearance.
3. Properly milled core improves thermal insulation and joint tightness.
4. Butyl sealing compound (applied at building site) protects against water
and moisture penetration.
5. Auxiliary groove allows for precise assembly.
6. Core made of environmentally friendly polystyrene.
7. Specially shaped micro-chamber protects against water capillary
penetration.
8. Hump made of environmentally friendly, natural polystyrene.

Airtight top technology

Financial and ecological benefits

Thanks to decades of expertise in sandwich panel production, intensive R&D, and comprehensive field measurements, we have succeeded in developing a new
airtight energy panel solution. Utilizing the solution
in a building will result in improved energy efficiency
and savings in maintenance costs.

The new energy panel solution creates savings in


heating costs, leading in turn to significantly reduced
carbon dioxide emissions generated by the use of the
building. Projects that are constructed in compliance
with the principles of sustainable development will
receive higher LEED* and BREEAM* credits. In addition to this, the indoor air quality will improve, as the
temperature becomes stabilized with no cold draft.
The value of your property will increase with environmental responsibility and image, high quality, and
lower running costs.

The energy panel solution consists of new, airtight


Ruukki energy panels, structural details, accessories,
airtightness instructions, as well as installation carried out by a certified Ruukki partner, and comes with
Ruukkis airtightness promise.

Ruukkis airtightness promise seals the deal

Our energy panels feature high-class joint tightness.


The panels are manufactured with minimal engineering tolerances, and special attention is paid to
production quality control in order to achieve superior
airtightness up to passive house standard. Our energy
panel solution is an excellent choice for industrial and
commercial buildings, logistics centers, and warehouses,
for instance. After the installation, final measurements will verify the airtightness of your building.

We have absolute faith in the airtightness of our energy panel solution. As the only manufacturer, Ruukki
is able to promise an exact airtightness level for a
building. The guarantee is agreed upon case-by-case
in a separate contract.
* Voluntary certificates assessing the environmental impact
of a building.
12

Sandwich panels for walls and roofs

Potential savings with Ruukki energy panel solution


Values based on a building located in Poland

Heat energy consumption (/year)

40 000

n50 = 3 l/h based on


technical conditions to
be fulfilled by buildings
and their location;
buildings with natural
ventilation.

35 000
30 000
25 000

Ruukki Basic
Ruukki Plus
Ruukki Premium

20 000
15 000
10 000
5000
0

1000m2 2000m2 3000m2 4000m2

6000m2 7000m2 8000m2


Floor area (m2)

Ruukki energy panel solution


Ruukki energy panels
- SP2B PU/PIR ENERGY
- SP2D PU/PIR ENERGY
- SP2E PU/PIR ENERGY
- SPB W ENERGY, SPB WE ENERGY
- SP2D W ENERGY, SP2D WE ENERGY
Structural details and accessories
Airtightness instructions
Installation carried out by a specialist firm certified by Ruukki

Airtightness levels
Premium and Plus levels are based on the new energy
panel solution, for which an airtightness promise is
given. The Basic level air leakage rate is n50 = 1.3 1/h.
This can be achieved by using Ruukkis ordinary panel
system.

PREMIUM

PLUS

BASIC

air leakage
rate
n500.6 1/h

air leakage
rate
n500.9 1/h

air leakage
rate
n501.3 1/ h

13

10000m2

Fire resistance
rigid
polyurethane foam

Ruukki SP2B PU

thickness
[mm]

40

60

80

100

fire
resistance

EI 153

EW 301
EI 153

EW 301
EI 152
EI 153

1 fire resistance of load bearing structure min. R30; max. distance between supports 4.0 m vertical and horizontal assembly arrangement;
2 fire resistance of load bearing structure min. R15; max. distance between supports 11.3 m horizontal assembly arrangement and 4.0 m vertical assembly arrangement;
3 fire resistance of load bearing structure min. R15; max. distance between supports 4.0 m horizontal assembly arrangement and 8.6 m vertical assembly arrangement; panel's facings made of stainless steel;

Ruukki SP2D PU
thickness
[mm]
fire
resistance

60

80

100

from
inside

E 151

EI 153

EI 153

from
outside

EW 304

EW 304

EW 304
EI 152

1 the inside is exposed to fire; fire resistance of load bearing structure min. R15; max. distance between supports 11.6 m horizontal assembly arrangement and 4.0 m vertical assembly arrangement;
2 the inside is exposed to fire; fire resistance of load bearing structure min. R15; max. distance between supports 4.0 m horizontal assembly arrangement and 4.0 m vertical assembly arrangement;
3 the inside is exposed to fire; fire resistance of load bearing structure min. R15; max. distance between supports 6.3 m horizontal assembly arrangement and 4.0 m vertical assembly arrangement;
4 the outside is exposed to fire; fire resistance of load bearing structure min. R30; max. distance between supports 4.0 m horizontal assembly arrangement and 4.0 m vertical assembly arrangement;

Ruukki SP2E PU
thickness
[mm]

120

fire
resistance

EI 15
EW 302
EI 153
EW 203

180

160
1

EI 15
EW 302
EI 153
EW 203
1

200

EI 15
EW 302
EI 153
EW 203
1

EI 151
EW 302
EI 153
EW 203

1 fire resistance of load bearing structure min. R15; max. distance between supports 10.0 m horizontal assembly arrangement and 4.0 m vertical assembly arrangement;
2 fire resistance of load bearing structure min. R30; max. distance between supports 4.0 m vertical and horizontal assembly arrangement;
3 fire resistance of load bearing structure correspondingly min. R15or R20; max. distance between supports 4.0 m horizontal assembly arrangement and 12.0 m vertical arrangement assembly; panel's facings made

of stainless steel;

Sandwich panels for walls and roofs

Ruukki SP2C PU
thickness
[mm]

fire
resistance

80/40

100/60

120/80

140/100

160/120

REI 151
RE 601

REI 151
RE 601

REI 151
RE 601

REI 151
RE 601

REI 151
RE 601

REI 202
RE 302

REI 202
RE 302

REI 303

REI 303

REI 303

1 fire resistance of load bearing structure correspondingly min. R15 or R60; span bending moment Md 0.0672 kNm/m; support bending moment Md -0.1200 kNm/m; snow load 0.2xS must be taken into consideration

when doing calculations;

2 fire resistance of load bearing structure correspondingly R20 or R30; span bending moment Md 0.0697 kNm/m; support bending moment Md -0.1245 kNm/m; snow load 0.2xS must be taken into consideration

when doing calculations;

3 fire resistance of load bearing structure min. R30; span bending moment Md 0.0896 kNm/m; support bending moment Md -0.1600 kNm/m; snow load 0.2xS must be taken into consideration when doing calcula-

tions;

Ruukki SPF PU
thickness
[mm]
fire
resistance

98/80

from
inside

EI 151
EW 301

from
outside

EW 602
E 1202

1 the inside is exposed to fire; fire resistance of load bearing structure correspondingly min. R15 or R30; max. distance between supports 3.0 m vertical and horizontal assembly arrangement;
2 the outside is exposed to fire; fire resistance of load bearing structure correspondingly min. R60 or R120; max. distance between supports 4.0 m vertical and horizontal assembly arrangement;

rigid
polyisocyanurate foam

Ruukki SP2B PIR

thickness
[mm]

40

60

80

100

fire
resistance

EW 301

EW 301

EI 152
EW 302

EI 153
EI 304
EW 304

1 fire resistance of load bearing structure min. R30; max. distance between supports 3.0 m vertical and horizontal assembly arrangement;
2 fire resistance of load bearing structure correspondingly min. R15 or R30; max. distance between supports 3.0 m vertical and horizontal assembly arrangement;
3 fire resistance of load bearing structure min. R15; max. distance between supports 11.9 m horizontal assembly arrangement and 4.0 m vertical assembly arrangement; providing that butyl sealing compound is used on both locks of

the panel;

4 fire resistance of load bearing structure min. R30; max. distance between supports 4.0 m vertical and horizontal assembly arrangement; providing that butyl sealing compound is used on both locks of the panel;

Ruukki SP2D PIR


thickness
[mm]

60

80

100

from
inside

EW 301

EW 30
El 152
EW 202

EW 301
EI 153

from
outside

EI 154
EW304

EI 154
EW304

EI 154
EW304

fire
resistance

1 the inside is exposed to fire; fire resistance of load bearing structure min. R30; max. distance between supports 3.0 m vertical and horizontal assembly arrangement;
2 the inside is exposed to fire; fire resistance of load bearing structure correspondingly min. R15 or R20; max. distance between supports 4.0 m vertical and horizontal assembly arrangement;
3 the inside is exposed to fire; fire resistance of load bearing structure min. R15; max. distance between supports 8.8 m vertical assembly arrangement and 4.0 horizontal assembly arrangement;
4 the outside is exposed to fire; fire resistance of load bearing structure correspondingly min. R15 or R30; max. distance between supports 4.0 m vertical and horizontal assembly arrangement;

Ruukki SP2E PIR


thickness
[mm]

120

160

180

200

fire
resistance

EI 151
EI 302
EW 302

EI 151
EI 302
EW 302

EI 151
EI 302
EW 302

EI 303
EW 303
EI 604
EW 604

2 fire resistance of load bearing structure min. R15; max. distance between supports 12.0 m vertical and horizontal assembly arrangement;
2fire resistance of load bearing structure min. R30; max. distance between supports 8.0 m horizontal assembly arrangement and 4.0 m vertical assembly arrangement;
3fire resistance of load bearing structure min. R30; max. distance between supports 12.0 m horizontal assembly arrangement and 4.0 m vertical assembly arrangement;
4fire resistance of load bearing structure min. R60; max. distance between supports 9.1 m horizontal assembly arrangement and 4.0 m vertical assembly arrangement

Ruukki SP2C PIR


thickness
[mm]
fire
resistance

80/40

100/60

120/80

140/100

160/120

REI 151
RE 901

REI 151
RE 901

REI 151
RE 901

REI 151
RE 901

REI 151
RE 901

REI 202
RE 302

REI 202
RE 302

REI 303
RE 603

REI 303
RE 603

REI 303
RE 603

1 fire resistance of load bearing structure correspondingly min. R15 or R90; span bending moment Md 0.0940 kNm/m; support bending moment Md -0.1680 kNm/m; snow load 0.2xS must be taken into considera-

tion when doing calculations;

2 fire resistance of load bearing structure correspondingly min. R20 or R30; span bending moment Md 0.1160 kNm/m; support bending moment Md -0.2070 kNm/m ; snow load 0.2xS must be taken into conside-

ration when doing calculations;

3 fire resistance of load bearing structure correspondingly min. R30 or R60; span bending moment Md 0.1210 kNm/m; support bending moment Md -0.2150 kNm/m; snow load 0.2xS must be taken into conside-

ration when doing calculations;

Sandwich panels for walls and roofs

hard mineral
wool

Ruukki SPB W

thickness
[mm]

80

100

120

140

160

200

fire
resistance

EI 301

EI 602
EI 903
EI 1204

EI 602
EI 903
EI 1204

EI 602
EI 903
EI 1204

EI 602
EI 903
EI 1204

EI 602
EI 903
EI 1204

1 fire resistance of load bearing structure min. R30; max. distance between supports 4.0 m vertical and horizontal assembly arrangement;
2 fire resistance of load bearing structure min. R60; max. distance between supports 11.9 m horizontal assembly arrangement and 4.0 m vertical assembly arrangement;
3 fire resistance of load bearing structure min. R90; max. distance between supports 10.2 m horizontal assembly arrangement and 4.0 m vertical assembly arrangement;
4 fire resistance of load bearing structure min. R120; max. distance between supports 9,9 m horizontal assembly arrangement and 4.0 m vertical assembly arrangement;

Ruukki SP2D W
thickness
[mm]

100

120

140

160

from
inside

EI 601
EI 904

EI 601

EI 601
EI 904

EI 601
EI 904

from
outside

EI 602
EI 904

EI 602

EI 602
EI 904

EI 602
EI 904

fire
resistance

or
from
inside

EI 453
EI 904

EI 453

EI 453
EI 904

EI 453
EI 904

from
outside

EI 904
EI 1205

EI 904
EI 1205

EI 904
EI 1205

EI 904
EI 1205

1 the inside is exposed to fire; fire resistance of load bearing structure min. R60; max. distance between supports 11.1 m horizontal assembly arrangement and 4.0 m vertical assembly arrangement;
2 the outside is exposed to fire; fire resistance of load bearing structure min. R60; max. distance between supports 11.1 m horizontal assembly arrangement and 4.0 m vertical assembly arrangement;
3 the inside is exposed to fire; fire resistance of load bearing structure min. R60; max. distance between supports 4.0 m horizontal assembly arrangement and 10.5 m vertical assembly arrangement;
4 the outside is exposed to fire; fire resistance of load bearing structure min. R1200; max. distance between supports 4.0 m horizontal assembly arrangement and 11.0 m vertical assembly arrangement;
5 the outside is exposed to fire; fire resistance of load bearing structure min. R1200; max. distance between supports 4.0 m horizontal assembly arrangement and 10.7 m vertical assembly arrangement;

Ruukki SPC W
thickness
[mm]

140/100

190/150

fire
resistance

REI 601
RE 1801

REI 601
RE 1801

1 fire resistance of load bearing structure correspondingly min. R60 or R180; span bending moment Md 0.1512 kNm/m, support bending moment Md -0.2700 kNm/m; snow load 0.2xS must be taken into consideration

when doing calculations;

soft mineral
wool

Ruukki SPB WE

thickness
[mm]

80

100

120

140

160

200

fire
resistance

EI 151
El 302

El 603
El 1204

El 603
El 1204

El 603
El 1204

El 603
El 1204

El 603
El 1204

1 fire resistance of load bearing structure min. R15; max. distance between supports 12.0 m horizontal assembly arrangement and 4.0 m vertical assembly arrangement;
2 fire resistance of load bearing structure min. R30; max. distance between supports 4.0 m vertical and horizontal assembly arrangement;
3 fire resistance of load bearing structure min. R60; max. distance between supports 4.0 m vertical and horizontal assembly arrangement;
4 fire resistance of load bearing structure min. R120; max. distance between supports 9.9 m horizontal assembly arrangement and 4.0 m vertical assembly arrangement;

Ruukki SP2D WE
thickness
[mm]

fire
resistance

100

120

140

160

from
inside

EI 301

EI 301

EI 301

EI 30

from
outside

El 902
El 1203

El 902
El 1203

El 902
El 1203

El 902
El 1203

1 fire resistance of load bearing structure min. R30; max. distance between supports 4.0 m horizontal assembly arrangement and 11.5 m vertical assembly arrangement;
2 fire resistance of load bearing structure min. R90; max. distance between supports 4.0 m horizontal assembly arrangement and 11.0 m vertical assembly arrangement;
3 fire resistance of load bearing structure min. R120; max. distance between supports 4.0 m horizontal assembly arrangement and 10.8 m vertical assembly arrangement;

Ruukki SPB S

rigid polystyrene
thickness
[mm]

60

80

100

140

200

fire
resistance

EW 601

EW 601

EW 601

EW 601

1 fire resistance of load bearing structure min. R60; max. distance between supports 3.0 m vertical and horizontal assembly arrangement;

Ruukki SPC S
thickness
[mm]

140/100

190/150

fire
resistance

RE 601

RE 601

1 fire resistance of load bearing structure min. R60; span bending moment Md 0.0672 kNm/m, support bending moment Md -0.1200 kNm/m; snow load 0.2xS must be taken into consideration when doing

calculations;

18

Sandwich panels for walls and roofs

Facing colour groups


colour group

colours

RAL 1015, 7035, 9002, 9010

II

RAL 9006
RR 20, 21, 24, 30, 40

III

RAL 3013, 5005, 6011, 7016, 9007


RR 22, 23, 29, 34, 35, 36, 41

19

Accessories

Corrosion resistance

Facings and coatings

Steel flashings
Standard length: 3000 mm.
Material: zinc-coated steel sheet.
Protective coating: polyester varnish.
Additional protection: foil.
Note: there is a possibility of making individual flashings
up to 6000 mm in length.

Fasteners
Self-drilling:
for hot-rolled structure (walls' thickness 3-12 mm),
for cold-bent structure (thickness 1.5-5 mm).
Note: fasteners are available in galvanized or lacquered white versions. On special demand it is possible to provide
hoods or fasteners in external facing colour of a sandwich
panel.

Facings and coatings

Seals
seals for Ruukki panels.

Other
instruments for installation and lifting of Ruukki panels,
sealing collars for sealing wire passage (for example ventilation) within Ruukki panels,
transparent panels,
socket, pads etc. for Ruukki SP2E PU panels.

Corrosion resistance
On the basis of research carried out, application possibilities for Ruukki sandwich panels with organic coatings/
facings were confirmed in the following environments:
Polyester coating of 25 m, C1 to C3 category acc. to
EN ISO 12944-2: 2001.
PVDF coating of 25 m, C1 to C3 category acc. to
EN ISO 12944-2: 2001.
Foil coating PVC (F) of 120 m, category C1 to C4 acc.
to EN ISO 12944-2: 2001.
Facing made of stainless steel of 0.55 or 0.60 mm,
C1 to C5-M category acc. to EN ISO 12944-2: 2001.
Special CSafe coating, up to C4 category acc. to EN ISO
12944-2:2001, providing better scratching, corrosion, dirt and
UV resistance as well as improved chemical resistance against
ammonia and sodium hydroxide.
20

Ruukki sandwich panels are made of a structural insulation


core (rigid, HCFC-free, self-extinguishing polyurethane
foam, mineral wool of very good fire resistance, or
polystyrene) and two facings made of steel sheet galvanized on both sides with organic coating. Standard
steel sheet is covered with polyester coating of 25 m
thickness in colour compliant to Ruukki sandwich panels
colour scheme. From interior side, steel sheet has a coating
that increases core adherence. On special order we offer
Ruukki sandwich panels made of zinc-coated steel sheets
with the following organic coatings:
PVDF coating of 25 m thickness, in white colour as
standard (other RAL colours on request). PVDF coating
has excellent corrosion resistance and resistance to
mechanical damage; the coating also provides long
term colour stability, even in temperature up to 120C.
PVC (F) film of 120 m thickness, in white colour is a
special coating of increased hardness, to apply in food
industry construction works and cold stores. PVC (F)
film is not susceptible to blurs, it is also easily washable
and resistant to most industrial cleaning agents.
On special order we also offer sandwich panels with facings made of stainless steel:
Corrosion resistant steel applied either on one or on
both sides of Ruukki wall panels SP2B PU and Ruukki
panels for cold-storage SP2E PU; panels with stainless steel facings are used in pharmaceutical and food
processing industry.

Sandwich panels for walls and roofs

R250

R275

R500

R550

Assembling during winter


Assemblig of panels which facing colours are in
III colour group [RAL 3013, 5005, 6011, 7016, 9007 &
RR 22, 23, 29, 34, 35, 36, 41] ought to be carried out
with min temperature 10C.

Ribbed profiling R250. Shopping center, Pila, Poland

New span of ribbed profiling

It allows to achieve more interesting architectural


effect and also to provide sandwich panels with the
best fire resistance, thermal and acoustic insulation parameters. Depth of ribbed profiling is ~1 mm,
ensuring thus clearly visible profiling result on
external cladding of facade panels.

In order to provide architects with additional


possibilities for creating interesting facades of
designed buildings we introduced new types of
ribbed profiling dedicated to external cladding
of wall sandwich panels with mineral wool core.
For Ruukki SP2D W and SP2D WE panel we offer
ribbed profiling with span of 250 mm and 500 mm.
For Ruukki SPB W and SPB WE - 1100 mm modular
width - we offer ribbed profiling with span of 275
mm and 550 mm. For Ruukki SPB W and SPB WE 1000 mm modular width - we offer ribbed profiling
with span of 250 mm and 500 mm.

Additional benefits
Sandwich panels with mineral wool core and new
types of ribbed profiling are a good alternative
for expensive solutions based on aluminum cassettes. Sandwich panels guarantee short installation time, easy selection of supplementary
elements, accessories and colours, maintaining
at the same time high quality look of designed
facade.

Features of ribbed profiling


Thickness of steel sheet used for external claddings
with new types of ribbed profiling is 0.60 mm.
21

Details of ribbed profiling

For SP2D W and SP2D WE panels ribbed profiling with span of


250 mm. Also available for SPB W panels with 1000 mm modular
width.

~1

~250

For SP2D W and SP2D WE panels ribbed profiling with span


of 500 mm. Also available for SPB W panels with 1000 mm
modular width.

~1

~500

For SPB W and SPB WE panels with 1100 mm modular width


ribbed profiling with span of 275 mm.

~1

~275

For SPB W and SPB WE panels with 1100 mm modular width


ribbed profiling with span of 550 mm.
22

~1

~550

RAL colours

Prof iling pattern

9010

~1

9002
~52

~52

L Linear

9006*

1015
3013
~16

5005

M Microprofiled

~1

6011
~28 (~250, ~275, ~500, ~550)

R Ribbed

7016
7035
9007*
Presented colours have a view character and may
differ in tone from the exact RAL colour.

P Embossed

18

~90

S Sinusoidal

Due to the complexity of technological processes, manufacturers of sheets with organic coatings do not guarantee
uniform colour tints in successive delivery lots. It refers
particularly to steel sheets in metallic colours RAL 9006
and RAL 9007.
Therefore, in order to avoid any problems related to tint
differences and to maintain uniform colour of panel facing,
Buyer should agree with Seller in writing, prior to the conclusion of sales agreement, which part of the order/agreement will refer to deliveries for one structure.
Once it is agreed by parties, Seller is obliged to fulfill
the order from one lot of input material. Otherwise Ruukki
Polska Sp. z o.o. bears no liability for possible differences
in colour tints.
In case of any questions please contact our Sales Department.

F Flat

23

CPL 021 EN / 05.2013 / Art&Print Sp. z o.o.

Ruukki Polska Sp. z o.o., Infoline


801 11 33 11
Customer service +48 46 85 81 600, +48 46 85 81 647,

www.ruukki.com

Copyright 2013 Rautaruukki Corporation. All rights reserved. Ruukki is a trademark of Rautaruukki Corporation.
Rautaruukki, Ruukki, Working. Living. Moving and Ruukki's product names are trademarks or registered trademarks of Rautaruukki Corporation.
Due to the ongoing product research and development works, Ruukki Polska Sp. z o.o. reserves the right to amend the content of this
catalogue without any prior notice. This publication does not constitute an offer as meant by the law.

You might also like