Professional Documents
Culture Documents
Ruukki Sandwich Panels For Walls and Roofs
Ruukki Sandwich Panels For Walls and Roofs
PANELS
FOR WALLS
AND ROOFS
BUILDING LIFETIME EFFICIENCY
www.ruukki.com/sandwichpanels
Ruukki SPF PU
Ruukki SP2D PU
core
rigid polyurethane
foam
rigid polyurethane
foam
thickness
[mm]
98 / 80
60
80
100
weight
[kg/m2]
15.3
10.3
11.0
11.7
value
Ruukki SPF PU
1. Large bend radii on facings ensure that none of the protective coat
properties is lost.
2. Facing profiling ensures uniform facade appearance.
3. Double lock from outer and inner sides increases fire-tightness and facilitates assembly.
4. Properly profiled edges improve thermal insulation and joint tightness.
5. Auxiliary groove allows for precise assembly.
6. Concealed panel fixings ensure aesthetic facade appearance.
7. Rigid, HCFC-free, self-extinguishing, environmentally and ozone friendly
polyurethane foam core provides excellent thermal insulation parameters.
8. Continuous polyurethane seal ensures proper thermal insulation and
joint tightness.
9. Aluminium foil prevents gas diffusion and penetration of vapour into
a polyurethane core (constant thermal parameters of panels).
10. Narrow, almost invisible 1 mm gap.
[W/mK]
0.022
U value
[W/m2K]4
0.23
reaction to fire
B-s3, d0
sound
insulation [dB]
25
0.022
0.35
0.26
0.21
B-s2,d0
24
18,5
maximum length
[m]
18.5
18.5
total width
[mm]
963.5
1050
modular width
[mm]
900
1000
external facing
thickness [mm]
0.60
0.50
internal facing
thickness [mm]
0.55
0.40
certificates
and approvals
Declaration of conformity
CE acc. to EN 14509
Hygienic Certificate
HC/97/779/104/2011
Declaration of conformity
CE acc. to EN 14509
Hygienic Certificate
HC/97/779/104/2011
external facing
profiling
S sinusoidal
R28 ribbed
L linear
P embossed
F flat1
M microprofiled
internal facing
profiling
L linear
F flat1
L linear
F flat1
possible
profiling
combinations
SL, SF
standard colours of
external facing
RAL5
9006
standard colours of
internal facing
RAL
9010
9002, 9010
other colours
see point2
see point2
Ruukki SP2D PU
1. Large bend radii on facings ensure that none of the protective coat
properties is lost.
2. Facing profiling ensures uniform facade appearance.
3. Double lock from outer and inner sides increases fire-tightness and
facilitates assembly.
4. Rigid, HCFC-free, self-extinguishing, environmentally and ozone friendly
polyurethane foam core provides excellent thermal insulation parameters.
5. Auxiliary groove allows for precise assembly.
6. Concealed panel fixings ensure aesthetic facade appearance.
7. Properly profiled edges improve thermal insulation and joint tightness.
8. Continuous polyurethane seal ensures proper thermal insulation and
joint tightness.
9. Aluminium foil prevents gas diffusion and penetration of vapour into
a polyurethane core (constant thermal parameters of panels).
10. Gas permeable polyurethane seal.
1 the surface of plain profile can be slightly corrugated min. facing thickness 0.50 mm.
2 other colours according to RAL system, available on special order, following additional arrangements. External
panel facings in dark colours (from standard colour range RAL 3013, 5005, 7016 and 9007), due to considerable
thermal loads, higher than that of lighter colours, can be deformed. In order to minimize this phenomenon, it
is advisable to apply only single-span systems for wall panels; for roof panels limitation to maximal lengths
resulting from calculations that take into cosideration thermal loads; in doubtful cases please consult construction department of panels producer.
Ruukki SP2B PU
Ruukki SP2E PU
rigid polyurethane
foam
rigid polyurethane
foam
core
40
60
80
100
120
160
180
200
thickness
[mm]
8.4
9.1
9.9
10.6
11.9
13.4
14.1
14.8
weight
[kg/m2]
0.50
0.35 0.26
value
0.021
0.022
[W/mK]
(temp. 0C)
0.21
0.17
0.13
0.11
0.10
U value
[W/m2K]4
B-s2,d0
B-s2, d0
reaction to fire
24
25
sound
insulation [dB]
18.5
18.5
maximum length
[m]
1120
1120
total width
[mm]
1100
1100
modular width
[mm]
0.50
0.50
external facing
thickness [mm]
0.40
0.50
internal facing
thickness [mm]
Declaration of conformity
CE acc. to EN 14509
Hygienic Certificate
HC/97/779/104/2011
Declaration of conformity
CE acc. to EN 14509
Hygienic Certificate
HC/97/779/104/2011
certificates
and approvals
R28 ribbed
L linear
P embossed
F flat1
M microprofiled
R28 ribbed
L linear
P embossed
F flat1
M microprofiled
L linear
F flat1
L linear
F flat1
1. Large bend radii on facings ensure that none of the protective coat
properties is lost.
2. Facing profiling ensures uniform facade appearance.
3. Double lock from outer and inner sides increases fire-tightness and facilitates assembly.
4. 3 mm gap enables to meet sanitary and hygienic requirements (food,
cooling, pharmaceutical industries etc.).
5. Properly profiled edges improve thermal insulation parameters and joint
tightness.
6. Rigid, HCFC-free, self-extinguishing, environmentally and ozone friendly
polyurethane foam core provides excellent thermal insulation parameters.
7. Aluminium foil prevents gas diffusion and penetration of vapour into
a polyurethane core (continuous thermal parameters of panels).
8. Continuous polyurethane seal ensures thermal insulation and joint
tightness.
external facing
profiling
internal facing
profiling
possible
profiling
combinations
standard colours of
external facing
RAL5
9002, 9010
9002, 9010
standard colours of
internal facing
RAL
see point2
see point2
other colours
Ruukki SP2B PU
Ruukki SP2E PU
1. Large bend radii on facings ensure that none of the protective coat
properties is lost.
2. 3 mm gap enables additional joint closure with durably elastic mass (p.8).
3. Precisely milled labyrinth core edge eliminates thermal bridges.
4. Double lock from outer and inner sides increases fire-tightness and
facilitates assembly.
5. Butyl sealing compound eliminates air and moisture penetration, applied at
building site.
6. Facing profile conforming with the standards applicable to cooling and food
industries ensures uniform facade appearance.
7. Rigid, HCFC-free and self-extinguishing environmentally and ozone friendly
polyurethane foam core of excellent thermal insulation.
8. Durably elastic sealing compound (compulsory for ceilings, optional for walls),
applied at building site.
Ruukki SP2C PU
core
rigid polyurethane
foam
thickness
[mm]
weight
[kg/m2]
9.5
10.3
value
Ruukki SP2C PU
1. Large bend radii on facings ensure that none of the protective coat properties is lost.
2. Facing profiling ensures uniform facade appearance.
3. Rigid, HCFC-free, self-extinguishing, environmentally and ozone friendly
polyurethane foam core provides excellent thermal insulation parameters.
4. Aluminium foil prevents gas diffusion and the penetration of vapour
into a polyurethane core (continuous thermal parameters of panels).
5. Auxiliary groove allows for precise assembly.
6. Properly profiled edges improve thermal insulation and joint tightness.
7. Specially shaped micro-chamber protects against water capillary penetration.
8. Continuous polyurethane seal ensures thermal insulation and joint
tightness.
11.7
12.5
14.3
80
100
10.4
11.2
12.0
0.022
[W/mK]
U value
[W/m2K]4
11.0
60
0.46
0.31
0.24
0.20
0.021
0.17
0.13
0.34
0.25 0.20
reaction to fire
B-s2,d0
60-80 B-s2,d0
100 B-s1,d0
external fire
exposure
BROOF (t1)
sound
insulation [dB]
24
24
maximum length
[m]
18.54
18.5
total width
[mm]
1083
1050
modular width
[mm]
1000
1000
external facing
thickness [mm]
0.50
0.50 or 0,60
internal facing
thickness [mm]
0.40
0.40
certificates
and approvals
Declaration of conformity
CE acc. to EN 14509
Hygienic Certificate
HC/97/779/104/2011
external facing
profiling
T trapezoidal
R28 ribbed
L linear
P embossed
F flat1
M microprofiled
internal facing
profiling
L linear
F flat1
possible
profiling
combinations
TL, TF
standard colours of
external facing
RAL6
standard colours of
internal facing
RAL
9002, 9010
9002, 9010
other colours
see point2
see point2
L linear
F flat1
1 the surface of plain profile can be slightly corrugated min. facing thickness 0.50 mm.
2 other colours according to RAL system, available on special order, following additional arrangements. External
panel facings in dark colours (from standard colour range RAL 3013, 5005, 7016 and 9007), due to considerable
thermal loads, higher than that of lighter colours, can be deformed. In order to minimize this phenomenon, it
is advisable to apply only single-span systems for wall panels; for roof panels limitation to maximal lengths
resulting from calculations that take into cosideration thermal loads; in doubtful cases please consult construction department of panels producer.
rigid polyisocyanurate
foam
rigid polyisocyanurate
foam
core
40
60
80
100
120
160
180
200
thickness
[mm]
8.5
9.3
10.1
10.9
12.4
14.0
14.8
15.6
weight
[kg/m2]
0.49
0.34
0.25
value
0.020
0.021
[W/mK]
(temp. 0C)
0.20
40-80 B-s2,d0
100 B-s1,d0
0.16
0.12
0.11
0.10
U value
[W/m2K]4
B-s1,d0
reaction to fire
external fire
exposure
24
25
sound
insulation [dB]
18.5
18.5
maximum length
[m]
1120
1120
total width
[mm]
1100
1100
modular width
[mm]
0.50 or 0.60
0,50 or 0.60
external facing
thickness [mm]
0.40
0.50
internal facing
thickness [mm]
Declaration of conformity
CE acc. to EN 14509
Hygienic Certificate
HC/97/779/104/2011
Declaration of conformity
CE acc. to EN 14509
Hygienic Certificate
HC/97/779/104/2011
R28 ribbed
L linear
P embossed
F flat1
M microprofiled
R28 ribbed
L linear
F flat1
M microprofiled
external facing
profiling
L linear
F flat1
L linear
F flat1
internal facing
profiling
possible
profiling
combinations
standard colours of
external facing
RAL6
9002, 9010
9002, 9010
standard colours of
internal facing
RAL
see point2
see point2
other colours
certificates
and approvals
Ruukki SP2D W
core
rigid polyisocyanurate
foam
hard mineral
wool
thickness
[mm]
weight
[kg/m2]
9.7
10.5
value
Ruukki SP2D W
1. Core made of rigid, environmentally friendly mineral wool provides
excellent fire resistance.
2. Properly milled core improves thermal insulation.
3. Large bend radii on facings ensure that none of the protective coat
properties is lost.
4. Facing profiling ensures uniform facade appearance.
5. Double lock from outer and inner sides increases fire-tightness and faci-
litates assembly.
6. Auxiliary groove allows for precise assembly.
7. Concealed panel fixings ensure aesthetic facade appearance.
8. Butyl sealing compound (applied at building site) protects against water
and moisture penetration.
12.1
12.9
14.9
0.021
[W/mK]
U value
[W/m2K]4
11.3
0.46
0.31
0.24 0.20
140 160
100 120
0.17
0.13
reaction to fire
80/40-120/80 B-s2,d0
140/100-210/170 B-s1,d0
A2-s2, d0
external fire
exposure
BROOF (t1)
sound
insulation [dB]
24
32
maximum length
[m]
18.52
total width
[mm]
1083
1054
modular width
[mm]
1000
1000
external facing
thickness [mm]
0.50
0.60
internal facing
thickness [mm]
0.40
0.50
certificates
and approvals
Declaration of conformity CE
acc. to EN 14509
Hygienic Certificate
HC/97/779/104/2011
external facing
profiling
T trapezoidal
internal facing
profiling
L linear
L linear
F flat
possible
profiling
combinations
TL
standard colours of
external facing
RAL4
1015, 5005,
7035, 9002, 9006,
9007, 9010
standard colours of
internal facing
RAL
9002, 9010
9002, 9010
other colours
see point1
see point1
1 other colours according to RAL system, available on special order, following additional arrangements. External
panel facings in dark colours (from standard colour range RAL 3013, 5005, 7016 and 9007), due to considerable
thermal loads, higher than that of lighter colours, can be deformed. In order to minimize this phenomenon, it
is advisable to apply only single-span systems for wall panels; for roof panels limitation to maximal lengths
resulting from calculations that take into cosideration thermal loads; in doubtful cases please consult
construction department of panels producer.
80
Ruukki SPB W
Ruukki SPC W
hard mineral
wool
hard mineral
wool
100
120
18.7 21.0
160
140
200
140/100
190/150
thickness
[mm]
22.0
27.8
weight
[kg/m2]
0.043
value
0.043
core
0.41
[W/mK]
0.28
U value
[W/m2K]4
A2-s2, d0
A2-s2, d0
reaction to fire
BROOF (t1)
external fire
exposure
32
34
sound
insulation [dB]
12.0
maximum length
[m]
1059
total width
[mm]
1000
modular width
[mm]
0.60
0.60
external facing
thickness [mm]
0.50
0.50
internal facing
thickness [mm]
T trapezoidal
external facing
profiling
L linear
F flat
L linear
F flat
internal facing
profiling
TL, TF
possible
profiling
combinations
1015, 5005,
7035, 9002, 9006,
9007, 9010
standard colours of
external facing
RAL4
9002, 9010
9002, 9010
standard colours of
internal facing
RAL
see point1
see point1
other colours
8,0
12,0
12,0
10,0
10,0
Ruukki SPB W
1. Large bend radii on facings ensure that none of the protective coat properties is lost.
2. Facing profiling ensures uniform facade appearance.
3. Double lock from outer and inner sides increases fire-tightness and facilitates assembly.
4. 3 mm gap enables to meet sanitary and hygienic requirements (food,
cooling, pharmaceutical industries, etc.).
5. Butyl sealing compound (applied at building site) protects against water
and moisture penetration.
6. Properly milled core improves thermal insulation and joint tightness.
7. Core made of rigid, environmentally friendly mineral wool provides
excellent fire resistance.
certificates
and approvals
Ruukki SPC W
1. Core made of rigid, environmentally friendly mineral wool provides excel-
lent fire resistance.
2. Hump made of environmentally friendly, hard mineral wool.
3. Properly milled core improves thermal insulation and joint tightness.
4. Large bend radii on facings ensure that none of the protective coat properties is lost.
5. Facing profiling ensures uniform facade appearance.
6. The lock from inner side increases fire-tightness and facilitates assembly.
7. Specially shaped micro-chamber protects against water capillary pene-
tration.
8. Auxiliary groove allows for precise assembly.
9. Butyl sealing compound (applied at building site) protects against water and moisture penetration.
core
soft mineral
wool
120
140
160
weight
[kg/m2]
19.0
20.8
22.6
24.4
U value
[W/m2K]4
soft mineral
wool
100
80
100
120
0.40
0.29
0.33
140
A2-s1, d0
A2-s1, d0
external fire
exposure
sound
insulation [dB]
29
29
12.0
12.0
12.0
10.0
8.0
12.0
12.0
10.0
10.0
total width
[mm]
1054
1018 or 1118
modular width
[mm]
1000
1000 or 1100
external facing
thickness [mm]
0.60
0.60
internal facing
thickness [mm]
0.50
0.50
Declaration of conformity
CE acc. to EN 14509
Hygienic Certificate
HC/97/779/104/2011
Declaration of conformity CE
acc. to EN 14509
Hygienic Certificate
HC/97/779/104/2011
external facing
profiling
internal facing
profiling
L linear
F flat
L linear
F flat
possible
profiling
combinations
standard colours of
external facing
RAL3
standard colours of
internal facing
RAL
9002, 9010
9002, 9010
other colours
see point1
see point1
certificates
and approvals
Ruukki SPB WE
1. Large bend radii on facings ensure that none of the protective coat properties is lost.
2. Facing profiling ensures uniform facade appearance.
3. Double lock from outer and inner sides increases fire-tightness and facilitates assembly.
4. 3 mm gap enables to meet sanitary and hygienic requirements (food,
cooling, pharmaceutical industries, etc.).
5. Butyl sealing compound (applied at building site) protects against water
and moisture penetration.
6. Properly milled core improves thermal insulation and joint tightness.
7. Core made of soft, environmentally friendly mineral wool provides
excellent fire resistance.
200
0.040
reaction to fire
maximum length
[m]
160
0.040
[W/mK]
Ruukki SPB WE
thickness
[mm]
value
Ruukki SP2D WE
Ruukki SP2D WE
1 other colours according to RAL system, available on special order, following additional arrangements. External
panel facings in dark colours (from standard colour range RAL 3013, 5005, 7016 and 9007), due to considerable
thermal loads, higher than that of lighter colours, can be deformed. In order to minimize this phenomenon, it is
advisable to apply only single-span systems for wall panels; for roof panels limitation to maximal lengths resulting
from calculations that take into cosideration thermal loads; in doubtful cases please consult construction
department of panels producer.
Ruukki SPB S
Ruukki SPC S
polystyrene
polystyrene
core
60
80
100
140
200
140/100
190/150
thickness
[mm]
9.5
9.8
10.0
10.5
11.0
11.0
12.0
weight
[kg/m2]
0.037
0.58
value
0.037
0.17
0.34
[W/mK]
0.23
U value
[W/m2K]4
B-s2, d0
B-s3, d0
reaction to fire
BROOF (t1)
external fire
exposure
26
sound
insulation [dB]
18.5
maximum length
[m]
1118
1059
total width
[mm]
1100
1000
modular width
[mm]
0.50
0.50
external facing
thickness [mm]
0.50
0.50
internal facing
thickness [mm]
L linear
M microprofiled
T trapezoidal
external facing
profiling
L linear
L linear
internal facing
profiling
LL, ML
TL
possible
profiling
combinations
standard colours of
external facing
RAL3
9002, 9010
9002, 9010
standard colours of
internal facing
RAL
see point1
see point1
other colours
24
12.0
1.0
18.5
18.5
18.5
Ruukki SPB S
1. Large bend radii on facings ensure that none of the protective coat properties is lost.
2. Facing profiling ensures uniform facade appearance.
3. Double lock from outer and inner sides increases fire-tightness and facilitates assembly.
4. 3 mm gap enables to meet sanitary and hygienic requirements (food,
cooling, pharmaceutical industries, etc.).
5. Butyl sealing compound (applied at building site) protects against water
and moisture penetration.
6. Properly milled core improves thermal insulation and joint tightness.
7. Core made of environmentally friendly polystyrene.
certificates
and approvals
Ruukki SPC S
1015, 6011, 7035, 9002,
9006, 9010
1. Large bend radii on facings ensure that none of the protective coat
properties is lost.
2. Facing profiling ensures uniform facade appearance.
3. Properly milled core improves thermal insulation and joint tightness.
4. Butyl sealing compound (applied at building site) protects against water
and moisture penetration.
5. Auxiliary groove allows for precise assembly.
6. Core made of environmentally friendly polystyrene.
7. Specially shaped micro-chamber protects against water capillary
penetration.
8. Hump made of environmentally friendly, natural polystyrene.
Thanks to decades of expertise in sandwich panel production, intensive R&D, and comprehensive field measurements, we have succeeded in developing a new
airtight energy panel solution. Utilizing the solution
in a building will result in improved energy efficiency
and savings in maintenance costs.
We have absolute faith in the airtightness of our energy panel solution. As the only manufacturer, Ruukki
is able to promise an exact airtightness level for a
building. The guarantee is agreed upon case-by-case
in a separate contract.
* Voluntary certificates assessing the environmental impact
of a building.
12
40 000
35 000
30 000
25 000
Ruukki Basic
Ruukki Plus
Ruukki Premium
20 000
15 000
10 000
5000
0
Airtightness levels
Premium and Plus levels are based on the new energy
panel solution, for which an airtightness promise is
given. The Basic level air leakage rate is n50 = 1.3 1/h.
This can be achieved by using Ruukkis ordinary panel
system.
PREMIUM
PLUS
BASIC
air leakage
rate
n500.6 1/h
air leakage
rate
n500.9 1/h
air leakage
rate
n501.3 1/ h
13
10000m2
Fire resistance
rigid
polyurethane foam
Ruukki SP2B PU
thickness
[mm]
40
60
80
100
fire
resistance
EI 153
EW 301
EI 153
EW 301
EI 152
EI 153
1 fire resistance of load bearing structure min. R30; max. distance between supports 4.0 m vertical and horizontal assembly arrangement;
2 fire resistance of load bearing structure min. R15; max. distance between supports 11.3 m horizontal assembly arrangement and 4.0 m vertical assembly arrangement;
3 fire resistance of load bearing structure min. R15; max. distance between supports 4.0 m horizontal assembly arrangement and 8.6 m vertical assembly arrangement; panel's facings made of stainless steel;
Ruukki SP2D PU
thickness
[mm]
fire
resistance
60
80
100
from
inside
E 151
EI 153
EI 153
from
outside
EW 304
EW 304
EW 304
EI 152
1 the inside is exposed to fire; fire resistance of load bearing structure min. R15; max. distance between supports 11.6 m horizontal assembly arrangement and 4.0 m vertical assembly arrangement;
2 the inside is exposed to fire; fire resistance of load bearing structure min. R15; max. distance between supports 4.0 m horizontal assembly arrangement and 4.0 m vertical assembly arrangement;
3 the inside is exposed to fire; fire resistance of load bearing structure min. R15; max. distance between supports 6.3 m horizontal assembly arrangement and 4.0 m vertical assembly arrangement;
4 the outside is exposed to fire; fire resistance of load bearing structure min. R30; max. distance between supports 4.0 m horizontal assembly arrangement and 4.0 m vertical assembly arrangement;
Ruukki SP2E PU
thickness
[mm]
120
fire
resistance
EI 15
EW 302
EI 153
EW 203
180
160
1
EI 15
EW 302
EI 153
EW 203
1
200
EI 15
EW 302
EI 153
EW 203
1
EI 151
EW 302
EI 153
EW 203
1 fire resistance of load bearing structure min. R15; max. distance between supports 10.0 m horizontal assembly arrangement and 4.0 m vertical assembly arrangement;
2 fire resistance of load bearing structure min. R30; max. distance between supports 4.0 m vertical and horizontal assembly arrangement;
3 fire resistance of load bearing structure correspondingly min. R15or R20; max. distance between supports 4.0 m horizontal assembly arrangement and 12.0 m vertical arrangement assembly; panel's facings made
of stainless steel;
Ruukki SP2C PU
thickness
[mm]
fire
resistance
80/40
100/60
120/80
140/100
160/120
REI 151
RE 601
REI 151
RE 601
REI 151
RE 601
REI 151
RE 601
REI 151
RE 601
REI 202
RE 302
REI 202
RE 302
REI 303
REI 303
REI 303
1 fire resistance of load bearing structure correspondingly min. R15 or R60; span bending moment Md 0.0672 kNm/m; support bending moment Md -0.1200 kNm/m; snow load 0.2xS must be taken into consideration
2 fire resistance of load bearing structure correspondingly R20 or R30; span bending moment Md 0.0697 kNm/m; support bending moment Md -0.1245 kNm/m; snow load 0.2xS must be taken into consideration
3 fire resistance of load bearing structure min. R30; span bending moment Md 0.0896 kNm/m; support bending moment Md -0.1600 kNm/m; snow load 0.2xS must be taken into consideration when doing calcula-
tions;
Ruukki SPF PU
thickness
[mm]
fire
resistance
98/80
from
inside
EI 151
EW 301
from
outside
EW 602
E 1202
1 the inside is exposed to fire; fire resistance of load bearing structure correspondingly min. R15 or R30; max. distance between supports 3.0 m vertical and horizontal assembly arrangement;
2 the outside is exposed to fire; fire resistance of load bearing structure correspondingly min. R60 or R120; max. distance between supports 4.0 m vertical and horizontal assembly arrangement;
rigid
polyisocyanurate foam
thickness
[mm]
40
60
80
100
fire
resistance
EW 301
EW 301
EI 152
EW 302
EI 153
EI 304
EW 304
1 fire resistance of load bearing structure min. R30; max. distance between supports 3.0 m vertical and horizontal assembly arrangement;
2 fire resistance of load bearing structure correspondingly min. R15 or R30; max. distance between supports 3.0 m vertical and horizontal assembly arrangement;
3 fire resistance of load bearing structure min. R15; max. distance between supports 11.9 m horizontal assembly arrangement and 4.0 m vertical assembly arrangement; providing that butyl sealing compound is used on both locks of
the panel;
4 fire resistance of load bearing structure min. R30; max. distance between supports 4.0 m vertical and horizontal assembly arrangement; providing that butyl sealing compound is used on both locks of the panel;
60
80
100
from
inside
EW 301
EW 30
El 152
EW 202
EW 301
EI 153
from
outside
EI 154
EW304
EI 154
EW304
EI 154
EW304
fire
resistance
1 the inside is exposed to fire; fire resistance of load bearing structure min. R30; max. distance between supports 3.0 m vertical and horizontal assembly arrangement;
2 the inside is exposed to fire; fire resistance of load bearing structure correspondingly min. R15 or R20; max. distance between supports 4.0 m vertical and horizontal assembly arrangement;
3 the inside is exposed to fire; fire resistance of load bearing structure min. R15; max. distance between supports 8.8 m vertical assembly arrangement and 4.0 horizontal assembly arrangement;
4 the outside is exposed to fire; fire resistance of load bearing structure correspondingly min. R15 or R30; max. distance between supports 4.0 m vertical and horizontal assembly arrangement;
120
160
180
200
fire
resistance
EI 151
EI 302
EW 302
EI 151
EI 302
EW 302
EI 151
EI 302
EW 302
EI 303
EW 303
EI 604
EW 604
2 fire resistance of load bearing structure min. R15; max. distance between supports 12.0 m vertical and horizontal assembly arrangement;
2fire resistance of load bearing structure min. R30; max. distance between supports 8.0 m horizontal assembly arrangement and 4.0 m vertical assembly arrangement;
3fire resistance of load bearing structure min. R30; max. distance between supports 12.0 m horizontal assembly arrangement and 4.0 m vertical assembly arrangement;
4fire resistance of load bearing structure min. R60; max. distance between supports 9.1 m horizontal assembly arrangement and 4.0 m vertical assembly arrangement
80/40
100/60
120/80
140/100
160/120
REI 151
RE 901
REI 151
RE 901
REI 151
RE 901
REI 151
RE 901
REI 151
RE 901
REI 202
RE 302
REI 202
RE 302
REI 303
RE 603
REI 303
RE 603
REI 303
RE 603
1 fire resistance of load bearing structure correspondingly min. R15 or R90; span bending moment Md 0.0940 kNm/m; support bending moment Md -0.1680 kNm/m; snow load 0.2xS must be taken into considera-
2 fire resistance of load bearing structure correspondingly min. R20 or R30; span bending moment Md 0.1160 kNm/m; support bending moment Md -0.2070 kNm/m ; snow load 0.2xS must be taken into conside-
3 fire resistance of load bearing structure correspondingly min. R30 or R60; span bending moment Md 0.1210 kNm/m; support bending moment Md -0.2150 kNm/m; snow load 0.2xS must be taken into conside-
hard mineral
wool
Ruukki SPB W
thickness
[mm]
80
100
120
140
160
200
fire
resistance
EI 301
EI 602
EI 903
EI 1204
EI 602
EI 903
EI 1204
EI 602
EI 903
EI 1204
EI 602
EI 903
EI 1204
EI 602
EI 903
EI 1204
1 fire resistance of load bearing structure min. R30; max. distance between supports 4.0 m vertical and horizontal assembly arrangement;
2 fire resistance of load bearing structure min. R60; max. distance between supports 11.9 m horizontal assembly arrangement and 4.0 m vertical assembly arrangement;
3 fire resistance of load bearing structure min. R90; max. distance between supports 10.2 m horizontal assembly arrangement and 4.0 m vertical assembly arrangement;
4 fire resistance of load bearing structure min. R120; max. distance between supports 9,9 m horizontal assembly arrangement and 4.0 m vertical assembly arrangement;
Ruukki SP2D W
thickness
[mm]
100
120
140
160
from
inside
EI 601
EI 904
EI 601
EI 601
EI 904
EI 601
EI 904
from
outside
EI 602
EI 904
EI 602
EI 602
EI 904
EI 602
EI 904
fire
resistance
or
from
inside
EI 453
EI 904
EI 453
EI 453
EI 904
EI 453
EI 904
from
outside
EI 904
EI 1205
EI 904
EI 1205
EI 904
EI 1205
EI 904
EI 1205
1 the inside is exposed to fire; fire resistance of load bearing structure min. R60; max. distance between supports 11.1 m horizontal assembly arrangement and 4.0 m vertical assembly arrangement;
2 the outside is exposed to fire; fire resistance of load bearing structure min. R60; max. distance between supports 11.1 m horizontal assembly arrangement and 4.0 m vertical assembly arrangement;
3 the inside is exposed to fire; fire resistance of load bearing structure min. R60; max. distance between supports 4.0 m horizontal assembly arrangement and 10.5 m vertical assembly arrangement;
4 the outside is exposed to fire; fire resistance of load bearing structure min. R1200; max. distance between supports 4.0 m horizontal assembly arrangement and 11.0 m vertical assembly arrangement;
5 the outside is exposed to fire; fire resistance of load bearing structure min. R1200; max. distance between supports 4.0 m horizontal assembly arrangement and 10.7 m vertical assembly arrangement;
Ruukki SPC W
thickness
[mm]
140/100
190/150
fire
resistance
REI 601
RE 1801
REI 601
RE 1801
1 fire resistance of load bearing structure correspondingly min. R60 or R180; span bending moment Md 0.1512 kNm/m, support bending moment Md -0.2700 kNm/m; snow load 0.2xS must be taken into consideration
soft mineral
wool
Ruukki SPB WE
thickness
[mm]
80
100
120
140
160
200
fire
resistance
EI 151
El 302
El 603
El 1204
El 603
El 1204
El 603
El 1204
El 603
El 1204
El 603
El 1204
1 fire resistance of load bearing structure min. R15; max. distance between supports 12.0 m horizontal assembly arrangement and 4.0 m vertical assembly arrangement;
2 fire resistance of load bearing structure min. R30; max. distance between supports 4.0 m vertical and horizontal assembly arrangement;
3 fire resistance of load bearing structure min. R60; max. distance between supports 4.0 m vertical and horizontal assembly arrangement;
4 fire resistance of load bearing structure min. R120; max. distance between supports 9.9 m horizontal assembly arrangement and 4.0 m vertical assembly arrangement;
Ruukki SP2D WE
thickness
[mm]
fire
resistance
100
120
140
160
from
inside
EI 301
EI 301
EI 301
EI 30
from
outside
El 902
El 1203
El 902
El 1203
El 902
El 1203
El 902
El 1203
1 fire resistance of load bearing structure min. R30; max. distance between supports 4.0 m horizontal assembly arrangement and 11.5 m vertical assembly arrangement;
2 fire resistance of load bearing structure min. R90; max. distance between supports 4.0 m horizontal assembly arrangement and 11.0 m vertical assembly arrangement;
3 fire resistance of load bearing structure min. R120; max. distance between supports 4.0 m horizontal assembly arrangement and 10.8 m vertical assembly arrangement;
Ruukki SPB S
rigid polystyrene
thickness
[mm]
60
80
100
140
200
fire
resistance
EW 601
EW 601
EW 601
EW 601
1 fire resistance of load bearing structure min. R60; max. distance between supports 3.0 m vertical and horizontal assembly arrangement;
Ruukki SPC S
thickness
[mm]
140/100
190/150
fire
resistance
RE 601
RE 601
1 fire resistance of load bearing structure min. R60; span bending moment Md 0.0672 kNm/m, support bending moment Md -0.1200 kNm/m; snow load 0.2xS must be taken into consideration when doing
calculations;
18
colours
II
RAL 9006
RR 20, 21, 24, 30, 40
III
19
Accessories
Corrosion resistance
Steel flashings
Standard length: 3000 mm.
Material: zinc-coated steel sheet.
Protective coating: polyester varnish.
Additional protection: foil.
Note: there is a possibility of making individual flashings
up to 6000 mm in length.
Fasteners
Self-drilling:
for hot-rolled structure (walls' thickness 3-12 mm),
for cold-bent structure (thickness 1.5-5 mm).
Note: fasteners are available in galvanized or lacquered white versions. On special demand it is possible to provide
hoods or fasteners in external facing colour of a sandwich
panel.
Seals
seals for Ruukki panels.
Other
instruments for installation and lifting of Ruukki panels,
sealing collars for sealing wire passage (for example ventilation) within Ruukki panels,
transparent panels,
socket, pads etc. for Ruukki SP2E PU panels.
Corrosion resistance
On the basis of research carried out, application possibilities for Ruukki sandwich panels with organic coatings/
facings were confirmed in the following environments:
Polyester coating of 25 m, C1 to C3 category acc. to
EN ISO 12944-2: 2001.
PVDF coating of 25 m, C1 to C3 category acc. to
EN ISO 12944-2: 2001.
Foil coating PVC (F) of 120 m, category C1 to C4 acc.
to EN ISO 12944-2: 2001.
Facing made of stainless steel of 0.55 or 0.60 mm,
C1 to C5-M category acc. to EN ISO 12944-2: 2001.
Special CSafe coating, up to C4 category acc. to EN ISO
12944-2:2001, providing better scratching, corrosion, dirt and
UV resistance as well as improved chemical resistance against
ammonia and sodium hydroxide.
20
R250
R275
R500
R550
Additional benefits
Sandwich panels with mineral wool core and new
types of ribbed profiling are a good alternative
for expensive solutions based on aluminum cassettes. Sandwich panels guarantee short installation time, easy selection of supplementary
elements, accessories and colours, maintaining
at the same time high quality look of designed
facade.
~1
~250
~1
~500
~1
~275
~1
~550
RAL colours
9010
~1
9002
~52
~52
L Linear
9006*
1015
3013
~16
5005
M Microprofiled
~1
6011
~28 (~250, ~275, ~500, ~550)
R Ribbed
7016
7035
9007*
Presented colours have a view character and may
differ in tone from the exact RAL colour.
P Embossed
18
~90
S Sinusoidal
Due to the complexity of technological processes, manufacturers of sheets with organic coatings do not guarantee
uniform colour tints in successive delivery lots. It refers
particularly to steel sheets in metallic colours RAL 9006
and RAL 9007.
Therefore, in order to avoid any problems related to tint
differences and to maintain uniform colour of panel facing,
Buyer should agree with Seller in writing, prior to the conclusion of sales agreement, which part of the order/agreement will refer to deliveries for one structure.
Once it is agreed by parties, Seller is obliged to fulfill
the order from one lot of input material. Otherwise Ruukki
Polska Sp. z o.o. bears no liability for possible differences
in colour tints.
In case of any questions please contact our Sales Department.
F Flat
23
www.ruukki.com
Copyright 2013 Rautaruukki Corporation. All rights reserved. Ruukki is a trademark of Rautaruukki Corporation.
Rautaruukki, Ruukki, Working. Living. Moving and Ruukki's product names are trademarks or registered trademarks of Rautaruukki Corporation.
Due to the ongoing product research and development works, Ruukki Polska Sp. z o.o. reserves the right to amend the content of this
catalogue without any prior notice. This publication does not constitute an offer as meant by the law.