Download as xls, pdf, or txt
Download as xls, pdf, or txt
You are on page 1of 1

Preliminary Heat Exchanger Design (U.S.

units) (page 1)
Estimation of Heat Transfer Area Needed

Inputs

Calculations

Fluid1 mass flow

Heat Transfer Rate, Q =

925,000

Log Mean Temp

79.6

rate, m1 =

25,000

Fluid1 temp. in, T1in =

190

Fluid1 temp. out, T1out =

140

Fluid1 sp. heat, Cp1 =

0.74

lb/hr
o

Btu/lb-oF

Fluid2 temp. in, T2in =

50

Fluid2 temp. out, T2out =

120

Fluid2 sp. heat, Cp2 =

1.0

Btu/lb-oF

Overall heat transf.


coeff. estim., U =

120

Btu/lhr-ft2-oF

Diff, DTlm =

Heat Transfer Area, A =

96.9

ft2

Fluid2 mass flow


rate, m2 =

Equations used for calculations:


Q = + (m1)(Cp1)(T1in - T1out)
Q = + (m2)(Cp2)(T2in - T2out)
DTlm = [(T1in - T2out) - (T1out - T2in)]/ln[(T1in - T2out)/(T1out - T2in)]
Q = U A DTlm

Btu/hr

13,214

lb/hr