Download as pdf
Download as pdf
You are on page 1of 2
20/03/2007 98:40 Page 049 file: +974-4352819 VELOSI CERT. -GATAR PAGE 81 Page | of 2 Wedge Socket oe 048 a WARNING WARNINGS AND APPLICATION INSTRUCTIONS 8-421 jUs-422 Important Safety Information - Read) Inspection: and Follow jaintenance Safety Aways opti wedge apn Ueto ang Do not use part shovling cracks. Do not use modified + Repair grinding until surfa dimension more than ‘© Inspect permanent: severe operating cor # Donot mix and mata lor substitute parts wicks gouges to socket or pin by Tightly 10%. Do not repair by welding, emblies annually, or more often in tions. ‘wedges or pins between models or Always select the rope size. bper wedge and socket for the wite Assembly Safoty NCNProgram Files « Loads may slip or fall if the Wedge Soc! is not properly installed, A falling load can seriously injure or kill ‘+ Read and understand these instruction: before installing the Wedge Socket. Do not side load the Wedge Socket. Do not interchange Crosby wedge sock wedge or pin with non Grosby wedge socket, wedge or pin. Apply first load to fully seat the Wedge Wire Rope in the socket. This load sho! be of equal or greater weight than loads expected in use. Do not interchange wedges between S- and US-422 or between sizes. s are smooth. Do not reduce original sby\2002 Crosby Catalog\HtmlNbody_049.htm RIGHT = WRONG rai Lenets standore 6 f 8 strand wie rope ranenim a8 ope diameters, but not fess tan 6 fe, -For (rope: Tal Length © se. 3/20/2007 20/03/2007 98:48 = +974-4352819 VELOSI CERT. -GATAR PAGE 02 Page 049 Page 2 of 2 i #- Use only with standhtd 61a 8 stand wie cape of F designeted size. Forlintermediate size rope, use next larger size cocket. For exainple: Whon using 9/16" diameter wire rope use a 5" size | Wedge Socket Assembly, Welding of the tail on standard Wire rope isnot recommended, The ang ofthe de end should be anima of 6 rope Operating Safety Figueo 1 Figure? ‘© Align live end of roge, with center line of pin, Pena ‘© Apply first Joad to fully seat the Wedge and Wi ‘Rope im the socket. This load should be of equa ‘= Socure dead end section of rope. (See Figure 1) ‘renter weight than loads expected in use, + DONOT ATTACH DEAD END TO LIVE END. ‘© Efficiency rating of the Wedge Socket temninat (See Figure 2). is based upon the catalog breaking strength of I } Rope. Tus effivienty uf properly assembled ‘Use a hammer to seat Wedge end Rope as deep into Wege Sockets 3076 chats pole : seisuspostie foaming sth rn dt st dead eon + Toe nth Rotate Rese wr rope ps aie inne rope constructions with 8 or more outer strands) ensure blocking) encanta bees es a ee acting th wns nthe medge slate ovat ‘core slippage or losslof rope lay. The tail length of the Seb Std sald bead mmo of 20 rope amet but ser as han "(ea gure, Copyright © 2003 The Crosby Group, Inc. All rights seaerved | fileviC:AProgram Fites\Grosby\2002 Crosby Catalog'\Htmlbody_049.htm 3/20/2007

You might also like