Download as pdf or txt
Download as pdf or txt
You are on page 1of 13

Tampilan awal

Klik board

Klik Configurations => NE Atribute

Ketik nama site di kolom name, Klik Apply.

Klik Modify NE ID

Masukkan New id dan New Extended ID => Klik OK.

Klik Ok

Klik OK, Kemudian aplikasi di Close.

Lalu Login Ulang

Masukkan Parameter, IF Channel Bandwidth, AM Status, Manual modulations, Guaranted E1 Capasity.


Frequency Attributes, T/R Spacing, TX Power.

Klik Apply, Kemudian Di Query

Perlu Diingat, Ketika site lawan dalam kondisi mati, Actual RX Power Harus -90

Cross Connect Software

Source => 3-ISU2, Source Timeslot Range (e.g.1,3-6) => 1-16, Source Timeslot Range (e.g.1,3-6) => 1-16.
Kemudian Klik OK.

Masukan IP, Klik Apply kemudian klik refresh. Aplikasi rtn di close, kemudian login lagi.

X-connect Vlan Pada RTN


Masuk configurations => Eternet Service Management => E-Lan Service => Klik New

Isi Kolom Service name => NodeB => Klik Ok

Klik Get UniPort

Boar 1-EM6T.
Geser sebelah kanan 1-EM6T-3 ke sebelah kanan

Boar 3-ISU2.
Geser sebelah kanan 3-ISU2 ke sebelah kanan

Masukkan V-lan, Kemudian klik Ok.

Jika E-lan Service Sudah Ter Created, Tinggal nambah di Get Uniport Saja

Geser Kesebelah kanan, port 1-EM6T yang kosong, kemudian masukkan vlannya.