ME-CA091

Contents

06

14

20

LG Electronics,
The Worlds Best Seller
Ceiling Concealed Duct
Type

Single Packaged Type

Ducted Split Type

24

Fan Coil Unit

36

MULTI M & M DX

The Worlds Number 1 Choice in Air Conditioners!

Models Line up
Btu/h

7,000

9,000

12,000

18,000

22,000

24,000

26,000

30,000

36,000

42,000

48,000

60,000

72,000

80,000

100,000

150,000

Ceiling Concealed Duct Type

Fan Coil Unit Type

Single Packaged Type

Ducted Split Type

3~6tons

3~6tons

7.5~30tons

3~5tons

7.5~12.5tons

15~20tons

* The exact appearance of products may vary from the images shown here.

Btu/h

Single Split Wall Mounted Type

Ceiling Cassette Type

Floor Standing Type

Ceiling and Floor Type

Ceiling Suspended Type

7,000

9,000

12,000

18,000

22,000
18,000

24,000

26,000

30,000

36,000

42,000

48,000

60,000

72,000

80,000

100,000

150,000

LG AIR CONDITIONERS 2009

Ceiling Concealed Duct Type

*E.S.P: External Static Pressure

Ceiling Concealed Duct Type


Hidden in the ceiling, this model is designed for buildings that require floor
level air conditioning for many individual rooms or large areas, like
restaurants, concert halls and hotels. Installation is not restricted by lighting
fixtures or the building layout, and interior renovation is made easy by
installing ventilation diffusers.

The air volume and sound level is kept constant as designed


regardless of changes in E.S.P.(External Static Pressure)
E.S.P. technology
- Optimizes Duct Installation
- Keeps Capacity & Sound Levels within desired ranges
- Reduces the number of models
Phase control motor technology reduces installation costs. The
desired air flow is obtained by adjusting the phase motor during
installation of the product, giving you more flexibility when
setting up your duct system. The E.S.P can be adjusted linearly
from 0 to 10mmAq.

PLASMA Air Purifying System (Accessory)


The integrated PLASMA Air Purifying System removes
microscopic contaminants and dust, eliminates offensive odors
and prevents allergic reactions. It can also be used as an airpurifying unit only, without running the air conditioner.

Evaluated by CSIRO Australia (DBCE Doc 98/204)


Tested by Korean Food Research Institute and Japanese Environmental
Centre and Yonsei Univ. College of Medicine. (Allergy Research Lab.)

Ceiling Concealed Duct Type

Dust Reduction
Respirable particles from 5 cigarettes in a sealed
room removed by the LG Plasma Air Purifying
System.

Deodorization
LG's Plasma Air Purifying unit effectively removes
high concentrations of tobacco odors (Confirmed
in sensory tests carried out in Korea and Japan.)

Anti-Allergy
In clinical tests, the LG Plasma Air Purifying System
reached a satisfaction level of 82% .

06
07

LG AIR CONDITIONERS 2009

Ceiling Concealed Duct Type

Long Distance Piping High Elevation


LG Air Conditioners (Cassette and Duct-type models) can be
installed at long distances (max 50m) and high height
differences (30m) from the outdoor unit.

LG AIR CONDITIONERS 2009

Ceiling Concealed Duct Type

Timer-controlled Operation
If desired, you can set operation times for up to one week in
advance.

Zone Controller (Accessory)

Central Controller (Accessory)

1) Basic Operation
- With a temperature sensor controlling every diffuser, the
temperature for each zone can be monitored and adjusted
automatically.
2) Control Features
- If every damper is closed, the compressor and outer fan are
turned off, to protect the compressor.

Plz refer to the picture below.

1) Basic Operation
- Linking several units, one Central Control Unit can manage
and turn off several units individually or as a group.
2) Control Features
- Each indoor unit is connected to a Central Control Unit via a
data communication cable and can be operated or turned off
individually or together with a group of units with the central
controller.
- The Central Control Unit can manage up to 8 * 16 indoor
units.

Option
Wireless Remote controller

30m

Ceiling Concealed Duct Type

50m

LCD Wired Remote Controller


24-Hour ON/ OFF Timer with 1 hour intervals
TEST RUN Mode
Zone A

Self-Diagnosis feature
3-Step Fan Speed selection

Zone B

Operation Indicator

Auto Changeover

Zone C

Room Temperature Display


Zone D

Only 20mm thick

Need not control on each times at big diurnal range areas.

High Head Drain Pump (Accessory)


08
The High Head Drain Pump pumps water up to 700mm high for
smooth drainage.

09

Zero standby power consumption

Heating

Target Temperature
Micro Processor

Outdoor Temperature

Analyze 3 Temperature

Indoor Temperature
Measure Periodically

Dehumidifying
Cooling

Pipe fixture

Two Thermistor Control


The dual thermistor control regulates the difference between
the indoor temperature and the temperature of the conditioned
air by monitoring both temperatures, to ensure a uniform room
temperature. The sensor readings are adjusted for optimum
room temperature.

700mm

Wall

Flexible
Drain Hose
Drain pump
Drain pipe

- Eliminates waste of electricity in standby mode.


- Electricity is wasted when an appliance is connected to an
outlet, even though the appliance is turned off.
- Development of a super power-saving SMPS
(Swiching Mode Power Supply)
- Minimal standby power consumption
(90% reduction of standby power).
- No need to pull the main power plug when the appliance is not
in use.

10

13

14

7
11
15
On

16

16

8
12

Off

Controller
#1

10

13

14

7
11
15
On

16

16

8
12

Off

Controller
#2

10

13

14

7
11
15
On

8
12
16
Off

Controller
#8

LG AIR CONDITIONERS 2009

Ceiling Concealed Duct Type

Ceiling Concealed Duct Type

LB-C186HSS1
LB-C246HSS1
Group Control

TB-H186HSS0
TB-H246HSS0

Gold Fin Anti Corrosion

1) Basic Operation
- Linking several units, one Group Control Unit can manage a
number of indoor units.
2) Control Features
- Through a data cable connected to each indoor unit, a group
of units can be managed from the group controller.
- The Group Control function is enabled by cutting an optional
jump wire in the wired remote control, which prevents data
collision.
- One Group Control Unit can control up to 16 indoor units.

LGs Outdoor Heat Exchanger is coated with a gold-colored


anti-corrosive epoxy treatment on the aluminum coil, to
prevent corrosion. This maintainsexcellent heat transfer
properties of the coil for an extended time, whereas non-Gold
Fin coils progressively lose efficiency due to surface
corrosion. Gold Fin fin is perfect for areas with high pollution
or locations exposed to saltwater spray from the sea.

Features
Long Distance, High Elevation Weekly Program Standby Power Zero Two Thermistor Control Group Control
Child Lock Function Auto Restart EZ Tuning Zone Control(Accessory) High Head Drain Pump(Accessory)
Wireless Remote Controller(Accessory) Gold Fin Anti Corrosion(Optional) PLASMA Air Purifying system(Accessory)
Central ControllerI(Accessory)

Salt Spray Test for 15 Days


Gold Coated Aluminum

After 15 Days

Uncoated Aluminum

After 15 Days

Specification
LG Gold Fin
Corrosion Free

Conventional
Starting to corrode

Model

LB-C186HSS1

TB-H186HSS0

LB-C246HSS1

TB-H246HSS0

Capacity
Cooling

Btu/hr

18,000

18,000

24,000

24,000

Heating

Btu/hr

18,000

24,000

,V,Hz

Electrical Data

1, 220~240,50

1, 220~240,50

1, 220~240,50

1, 220~240,50

Power Input

Cooling / Heating

2,020 / -

2,020 / 2,020

2,750 / -

2,700 / 2,700

Running Current

Cooling / Heating

9.5 / -

9.5 / 9.5

12 / -

12.0 / 12.0
8.89

Power Supply

Performance

........

16

EER

Cooling

Btu/hr.W

8.91

8.91

8.73

COP

Heating

W/W

2.90

2.61

Air Circulation

Indoor(H/M/L)

CMM

16/14.5/13

16/14.5/13

18/16.5/14

18/16.5/14

1.5

1.5

2.7

2.7

Indoor(H/M/L)

dB(A)3

36/34/32

36/34/32

37/35/33

37/35/33

Outdoor Max

dB(A)3

55

55

55

55

mmAq

3*2.5

3*2.5

3*2.5

3*2.5

4*0.75*220

5*0.75*220

4*0.75*220

5*0.75*220

Moisture Removal
Noise Level

l /hr

External Static Pressure


Cable
........

Main

No.*(mm2)*Max L.(m)

Conneting No.*(mm2)*Max L.(m)


Installation & Stuffing
Net Dimensions

Indoor

mm

880*260*450

880*260*450

880*260*450

880*260*450

(WxHxD)

Outdoor

mm

870*655*320

870*655*320

870*800*320

870*800*320

Net Weight

Indoor/Outdoor

Kg

35/55

35/55

35/60

35/60

Stuffing Quantity

Without S/Parts

20/40ft

52/107

52/107

44/85

44/85

Service Valve

Liquid/Gas

(mm)

6.35/15.88

6.35/15.88

6.35/15.88

6.35/15.88

Note :Due to our policy of innovation some specifications may be changed without notification.

10

11

Ceiling Concealed Duct Type

LB-C306GSS1
LB-C366GSS1

Ceiling Concealed Duct Type

TB-H306GSS0
TB-H366GSS0

LB-C368GSS1
LB-C428GSS1

TB-H368GSS0
TB-H428GSS0

Features

Features

Long Distance, High Elevation Weekly Program Standby Power Zero Two Thermistor Control Group Control
Child Lock Function Auto Restart EZ Tuning Zone Control(Accessory) High Head Drain Pump(Accessory)
Wireless Remote Controller(Accessory) Gold Fin Anti Corrosion(Optional) PLASMA Air Purifying system(Accessory)
Central ControllerI(Accessory)

Long Distance, High Elevation Weekly Program Standby Power Zero Two Thermistor Control Group Control
Child Lock Function Auto Restart EZ Tuning Zone Control(Accessory) High Head Drain Pump(Accessory)
Wireless Remote Controller(Accessory) Gold Fin Anti Corrosion(Optional) PLASMA Air Purifying system(Accessory)
Central ControllerI(Accessory)

Specification

Specification

Model

LB-C306GSS1

TB-H306GSS0

LB-C366GSS1

TB-H366GSS0

Capacity

Model

LB-C368GSS1

TB-H368GSS0

LB-C428GSS1

TB-H428GSS0

Capacity

Cooling

Btu/hr

30,000

30,000

36,000

36,000

Cooling

Btu/hr

36,000

36,000

42,000

42,000

Heating

Btu/hr

30,000

36,000

Heating

Btu/hr

36,000

42,000

,V,Hz

Electrical Data

Electrical Data

1, 220~240,50

1, 220~240,50

1, 220~240,50

1, 220~240,50

Power Supply

3, 380~415, 50

3, 380~415, 50

3, 380~415, 50

3, 380~415, 50

Power Input

Cooling / Heating

3,600 / -

3,400 / 3,400

4,100 / -

4,100 / 4,100

Power Input

Cooling / Heating

4,100 / -

4,100 / 4,100

5,000 / -

5,100 / 5,400

Running Current

Cooling / Heating

17.0 / -

15 / 15

18.8 / -

18.8 / 18.8

Running Current

Cooling / Heating

6.3 / -

6.3 / 6.3

7.8 / -

8 / 8.5
8.24

Power Supply

,V,Hz

Performance

Performance

EER

Cooling

Btu/hr.W

8.33

8.82

8.78

8.78

EER

Cooling

Btu/hr.W

8.78

8.78

8.40

COP

Heating

W/W

2.59

2.57

COP

Heating

W/W

2.57

2.41

Air Circulation

Indoor(H/M/L)

CMM

28/26/24

28/26/24

32/29/26.5

32/29/26.5

Air Circulation

Indoor(H/M/L)

CMM

32/29/26.5

32/29/26.5

32/29/26.5

32/29/26.5

3.5

3.5

3.5

3.5

4.5

4.5

Indoor(H/M/L)

dB(A)3

43/42/40

43/42/40

43/42/40

43/42/40

Indoor(H/M/L)

dB(A)3

43/42/40

43/42/40

43/42/40

43/42/40

Outdoor Max

dB(A)3

56

56

58

58

Outdoor Max

dB(A)3

58

58

59

59

mmAq

mmAq

3*3.5

3*3.5

3*5.5

3*5.5

5*2.5

5*2.5

5*2.5

5*2.5

4*0.75*220

5*0.75*220

4*0.75*220

5*0.75*220

4*0.75*220

5*0.75*220

4*0.75*220

5*0.75*220

Moisture Removal
Noise Level

l /hr

External Static Pressure


Cable

Main

No.*(mm2)*Max L.(m)

Conneting No.*(mm2)*Max L.(m)


Installation & Stuffing

Moisture Removal
Noise Level

l /hr

External Static Pressure


Cable

Main

No.*(mm2)*Max L.(m)

Conneting No.*(mm2)*Max L.(m)


Installation & Stuffing

Net Dimensions

Indoor

mm

1,180x298x450

1,180x298x450

1,180x298x450

1,180x298x450

Net Dimensions

Indoor

mm

1,180x298x450

1,180x298x450

1,180x298x450

1,180x298x450

(WxHxD)

Outdoor

mm

870x800x320

870x800x320

870x800x320

870x1,038x320

(WxHxD)

Outdoor

mm

870x1,038x320

870x1,038x320

870x1,038x320

900x1,165x370

Net Weight

Indoor/Outdoor

Kg

38/65

38/65

38/70

38/78

Net Weight

Indoor/Outdoor

Kg

38/78

38/78

38/78

38/95

Stuffing Quantity

Without S/Parts

20/40ft

31/69

31/69

31/69

30/63

Stuffing Quantity

Without S/Parts

20/40ft

30/63

30/63

30/63

27/55

Service Valve

Liquid/Gas

(mm)

6.35/15.88

6.35/15.88

9.52/15.88

6.35/15.88

Service Valve

Liquid/Gas

(mm)

6.35/15.88

6.35/15.88

9.52/19.05

9.52/19.05

Note :Due to our policy of innovation some specifications may be changed without notification.

12

Note :Due to our policy of innovation some specifications may be changed without notification.

13

Ceiling Concealed Duct Type

LB-C488RSS1
LB-C608RSS1

Ceiling Concealed Duct Type

TB-H488RSS0
TB-H608RSS0

LB-C186HSA4

LB-C246HSA4

Features

Features

Long Distance, High Elevation Weekly Program Standby Power Zero Two Thermistor Control Group Control
Child Lock Function Auto Restart EZ Tuning Zone Control(Accessory) High Head Drain Pump(Accessory)
Wireless Remote Controller(Accessory) Gold Fin Anti Corrosion(Optional) PLASMA Air Purifying system(Accessory)
Central ControllerI(Accessory)

Long Distance, High Elevation Weekly Program Standby Power Zero Two Thermistor Control Group Control
Child Lock Function Auto Restart EZ Tuning Zone Control(Accessory) High Head Drain Pump(Accessory)
Wireless Remote Controller(Accessory) Gold Fin Anti Corrosion(Optional) PLASMA Air Purifying system(Accessory)
Central ControllerI(Accessory)

Specification

Specification

Model

LB-C488RSS1

TB-H488RSS0

LB-C608RSS1

TB-H608RSS0

Capacity

Model

LB-C186HSA4

LB-C246HSA4

Capacity

Cooling

Btu/hr

48,000

48,000

56,000

56,000

Cooling

Btu/hr

18,000

24,000

Heating

Btu/hr

48,000

58,000

Heating

Btu/hr

,V,Hz

Electrical Data

Electrical Data

3, 380~415, 50

3, 380~415, 50

3, 380~415, 50

3, 380~415, 50

Power Input

Cooling / Heating

5,750 / -

5,600 / 5,000

6,800 / -

6,800 / 6,250

Running Current

Cooling / Heating

9/-

8.7 / 7.7

10.5 / -

10.5 / 9.8

Power Supply

,V,Hz

Performance

1, 220~240, 50

1, 220~240, 50

Power Input

Cooling / Heating

2,000 / -

2,880 / -

Running Current

Cooling / Heating

9.2 / -

13 / -

9.0

8.6

Power Supply

Performance

EER

Cooling

Btu/hr.W

8.35

8.57

8.24

8.24

EER

Cooling

Btu/hr.W

COP

Heating

W/W

2.81

2.72

COP

Heating

W/W

Air Circulation

Indoor(H/M/L)

CMM

40/35/30

40/35/30

50/45/40

50/45/40

Air Circulation

Indoor(H/M/L)

CMM

16/14.5/13

18/16.5/14

5.5

5.5

2.0

2.50

Indoor(H/M/L)

dB(A)3

46/44/42

46/44/42

49/47/45

49/47/45

Indoor(H/M/L)

dB(A)3

36/34/32

37/35/33

Outdoor Max

dB(A)3

59

59

60

60

Outdoor Max

dB(A)3

55

57

mmAq

10

10

10

10

mmAq

5*3.5

5*3.5

5*3.5

5*3.5

No.*(mm2)*Max L.(m)

3*3.5

3*3.5

4*1.25*220

5*1.25*220

4*1.25*220

5*1.25*220

Conneting No.*(mm2)*Max L.(m)

4*0.75

4*0.75

Moisture Removal
Noise Level

l /hr

External Static Pressure


Cable

Main

No.*(mm2)*Max L.(m)

Conneting No.*(mm2)*Max L.(m)


Installation & Stuffing

Moisture Removal
Noise Level

l /hr

External Static Pressure


Cable

Main

Installation & Stuffing

Net Dimensions

Indoor

mm

1,230x380x590

1,230x380x590

1,230x380x590

1,230x380x590

Net Dimensions

Indoor

mm

880x260x450

880x260x450

(WxHxD)

Outdoor

mm

900x1,165x370

900x1,165x370

900x1,165x370

900x1,165x370

(WxHxD)

Outdoor

mm

801x555x262

870x655x320

Net Weight

Indoor/Outdoor

Kg

52/95

52/95

52/105

52/105

Net Weight

Indoor/Outdoor

Kg

35/50

35/55

Stuffing Quantity

Without S/Parts

20/40ft

24/48

24/48

24/48

24/48

Stuffing Quantity

Without S/Parts

20/40ft

63/134

52/106

Service Valve

Liquid/Gas

(mm)

9.52/19.05

9.52/19.05

12.7/19.05

12.7/19.05

Service Valve

Liquid/Gas

(mm)

6.35/15.88

6.35/15.88

Note :Due to our policy of innovation some specifications may be changed without notification.

14

Note :Due to our policy of innovation some specifications may be changed without notification.

15

Ceiling Concealed Duct Type

LB-C306GSA0
LB-C428GSA0

Ceiling Concealed Duct Type

LB-C366GSA0

LB-C488RSA0

LB-C608RSA0

Features

Features

Long Distance, High Elevation Weekly Program Standby Power Zero Two Thermistor Control Group Control
Child Lock Function Auto Restart EZ Tuning Zone Control(Accessory) High Head Drain Pump(Accessory)
Wireless Remote Controller(Accessory) Gold Fin Anti Corrosion(Optional) PLASMA Air Purifying system(Accessory)
Central ControllerI(Accessory)

Gold Fin Anti Corrosion et CoolTM Auto Cleaning Auto Restart Natural Wind By CHAOS Swing
Wireless Remote Controller Quiet Operation Sleep Mode Auto Operation One-Touch Air Filter(Anti-Bacteria)
Healthy Dehumidification 24-Hour ON/OFF Setting Timer

Specification

Specification

Model

LB-C306GSA0

LB-C366GSA0

LB-C428GSA0

Capacity

Model

LB-C488RSA0

LB-C608RSA0

Capacity

Cooling

Btu/hr

30,000

36,000

42,000

Cooling

Btu/hr

48,000

60,000

Heating

Btu/hr

Heating

Btu/hr

,V,Hz

Electrical Data

Electrical Data

1, 220~240, 50

1, 220~240, 50

3, 380~415, 50

Power Input

Cooling / Heating

3,500 / -

4,500 / -

5,000 / -

Running Current

Cooling / Heating

16.0 / -

20.0 / -

7.8 / -

Power Supply

,V,Hz

Performance

3, 380~415, 50

3, 380~415, 50

Power Input

Cooling / Heating

5,100 / -

6,500 / -

Running Current

Cooling / Heating

8.0 / -

10.2 / -

9.4

9.2

Power Supply

Performance

EER

Cooling

Btu/hr.W

8.6

8.4

EER

Cooling

Btu/hr.W

COP

Heating

W/W

COP

Heating

W/W

Air Circulation

Indoor(H/M/L)

CMM

28/26/24

32/29/26

32/29/26

Air Circulation

Indoor(H/M/L)

CMM

40/35/30

50/45/40

3.00

3.50

4.5

5.00

5.50

Indoor(H/M/L)

dB(A)3

42/40/38

42/40//38

42/40/38

Indoor(H/M/L)

dB(A)3

44/42/40

46/44/42

Outdoor Max

dB(A)3

60

59

60

Outdoor Max

dB(A)3

62

61

mmAq

mmAq

10

10

No.*(mm2)*Max L.(m)

3*3.5

3*5.5

4*2.5

No.*(mm2)*Max L.(m)

4*3.5

4*3.5

Conneting No.*(mm2)*Max L.(m)

4*0.75

4*0.75

4*0.25

Conneting No.*(mm2)*Max L.(m)

4*1.25

4*1.25

Moisture Removal
Noise Level

l /hr

External Static Pressure


Cable

Main

Installation & Stuffing

Moisture Removal
Noise Level

l /hr

External Static Pressure


Cable

Main

Installation & Stuffing

Net Dimensions

Indoor

mm

1,180x298x450

1,180x298x450

1,180x298x450

Net Dimensions

Indoor

mm

1,230x380x590

1,230x380x590

(WxHxD)

Outdoor

mm

870x800x320

870x800x320

870x1,038x320

(WxHxD)

Outdoor

mm

900x1,165x370

900x1,165x370

Net Weight

Indoor/Outdoor

Kg

38/60

38/70

38/78

Net Weight

Indoor/Outdoor

Kg

52/95

52/105

Stuffing Quantity

Without S/Parts

20/40ft

34/73

34/73

34/73

Stuffing Quantity

Without S/Parts

20/40ft

24/49

24/49

Service Valve

Liquid/Gas

(mm)

6.35/15.88

9.52/15.88

9.52/15.88

Service Valve

Liquid/Gas

(mm)

9.52/15.88

12.7/19.05

Note :Due to our policy of innovation some specifications may be changed without notification.

16

Note :Due to our policy of innovation some specifications may be changed without notification.

17

LG AIR CONDITIONERS 2009

Single Packaged Type

Easy Installation

Single Packaged Type

The unit can be installed outdoors to save valuable indoor


space, or in locations where no ceiling space is available.
Ground or roof installation options provide total flexibility
according to your requirements.

Economical and user-friendly model, designed for medium-sized houses


and shops. Features include a number of operation modes, auto restart and
a washable anti-bacterial filter.

LGs Cooling Load Calculation Program


Selecting an air conditioner with the right capacity is very
important. A unit that is too small or too big will not only affect
your comfort, but may also unnecessarily increase your initial
purchasing cost and operational expenses. The LG cooling load
calculation program helps you choose the right system for your
specific needs.

Easy Maintenance & Service


Single Packaged Type

The all-in-one design, with all access panels located on one


side of the unit and color-coded wiring, greatly facilitates
maintenance and service.

Typical Installation
Roof Jack Installation
Roof Curb Installation
Slab-on-Ground Installation

Additional functions available with duct


system

18
All units are designed for reverse-cycle operation, which means
electric heating functions can be added by specialized dealers.
This model also allows complete control over fresh air intake,
ratio of air purification, as well as monitoring and automatic
zone control (additional features available from specialized
dealers), through the powerful LG control system.

Free & Easy Air-Circulation


A duct system allows you to freely control air-circulation.

19

Single Packaged Type

TK-C0368HA0
TK-C0608HA0

Single Packaged Type

TK-C0488HA0

TK-C0728H00

TK-C0908H00

* The exact appearance of products may vary from the images shown here.

* The exact appearance of products may vary from the images shown here.

Features

Features

Compact & Lightweight Design U-shape Air Flow Safety Condenser Fin Guard Forklift Base rail Easy access Panel
Time Delay Relay is Standard Component Low Pressure Switch is Standard Component Durable Painted Steel Cabinet
Scroll Compressor with internal high-pressure & Over-current Protector Factory Charged Refrigerant
Direct-drive multi-speed PSC Blower Motor Direct-drive PSC Condenser Fan Motor Phase reversal Protection

Wired LCD Remote Controller Easy Installation Auto Restart Low Noise Level
Easy Maintenance & Service Additional Functions Available with Duct System

Specification

Specification

Model

TK-C0368HA0

TK-C0488HA0

TK-C0608HA0

Capacity

Model

TK-C0728H00

TK-C0908H00

Capacity

Cooling

Btu/hr

35,700

48,400

59,900

Cooling

Btu/hr

72,000

96,000

Heating

Btu/hr

Heating

Btu/hr

3, 380~415,50

Electrical Data

Electrical Data

Power Supply

,V,Hz

3, 380~415,50

3, 380~415,50

3, 380~415,50

Power Supply

,V,Hz

3, 380~415,50

M.C.A(with standard motor) Cooling / Heating

Amps

13.2

17

21.6

M.C.A(with standard motor) Cooling / Heating

Amps

22.8

24.7

4,000

4,900

6,400

Power Input

8,600

9,500

CMM

34

45.3

56.7

Air Circulation

CMM

73.1

81.3

bell

7.7

7.9

8.0

Sound Rating

bell

7.6

8.5

mm

1,784x1,147x1,202

1,784x1,147x1,202

Kg

260

310

8/18/18

8/18/18

Power Input

Cooling / Heating

Performance
Air Circulation

Performance
Indoor

Sound Rating
Installation & Stuffing

Indoor

Installation & Stuffing


mm

1,111x824x734

1,111x824x734

1,111x824x734

Kg

110

120

140

30/64/96

30/64/96

30/64/96

Net Dimensions

(WxHxD)

Net Weight

Indoor/Outdoor

Stuffing Quantity

Without S/Parts 20/40/40ft Hi

Note :Due to our policy of innovation some specifications may be changed without notification.

20

Cooling / Heating

Net Dimensions

(WxHxD)

Net Weight

Indoor/Outdoor

Stuffing Quantity

Without S/Parts 20/40/40ft Hi

Note :Due to our policy of innovation some specifications may be changed without notification.

21

Single Packaged Type

TK-C1208H00

Single Packaged Type

TK-C1508H00

GK-C1808C00
GK-C2408C00
GK-C3608H00

GK-C2108C00
GK-C3008C00

* The exact appearance of products may vary from the images shown here.

* The exact appearance of products may vary from the images shown here.

Features

Features

Washable Anti-bacteria Filter Wired LCD Remote Controller Easy Installation


Oversized moter (Accessory) Low Noise Level Easy Maintenance & Service
Additional Functions Available with Duct System Auto Restart

Washable Anti-bacteria Filter Wired LCD Remote Controller Easy Installation


Oversized moter (Accessory) Low Noise Level Easy Maintenance & Service
Additional Functions Available with Duct System Auto Restart

Specification

Specification

Model

TK-C1208H00

TK-C1508H00

Capacity

Model

Cooling (Gross)

Btu/hr

112,600

129,600

Heating

Btu/hr

Electrical Data

GK-C3008C00

GK-C3608H00

Btu/hr

175,000

197,000

238,900

280,400

360,000

Btu/hr

Power Supply

,V,Hz

3, 380~415,50

3, 380~415,50

3, 380~415,50

3, 380~415,50

3, 380~415,50

M.C.A(with standard motor) Cooling / Heating

Amps

52.7

57

68.4

80.1

86.4

18,000

20,500

25,000

28,500

33,000

CMM

165

198

226

280.0283

311

bell

9.2

9.2

9.2

9.2

10

mm

2,230x1,244x1,540

2,230x1,244x1,540

2,893x1,250x2,200

2,893x1,250x2,200

2,688x1,720x2,220

Kg

550

600

870

870

1,070

3/7/14

3/7/14

1/4/8

1/4/8

2/4/4

Electrical Data
,V,Hz

3, 380~415,50

3, 380~415,50

Amps

24.9

33

13,500

15,600

CMM

104

155

Air Circulation

bell

8.5

8.6

Sound Rating

Cooling / Heating

Performance

Power Input

Cooling / Heating

Performance
Indoor

Sound Rating
Installation & Stuffing

Indoor

Installation & Stuffing


mm

2,110x1,250x1,280

2,110x1,250x1,280

Kg

400

400

4/9/18

4/9/18

Net Dimensions

(WxHxD)

Net Weight

Indoor/Outdoor

Stuffing Quantity

Without S/Parts 20/40/40ft Hi

Note :Due to our policy of innovation some specifications may be changed without notification.

22

GK-C2408C00

Heating

M.C.A(with standard motor) Cooling / Heating

Air Circulation

GK-C2108C00

Cooling (Gross)

Power Supply

Power Input

GK-C1808C00

Capacity

Net Dimensions

(WxHxD)

Net Weight

Indoor/Outdoor

Stuffing Quantity

Without S/Parts 20/40/40ft Hi

Note :Due to our policy of innovation some specifications may be changed without notification.

23

Ducted Split Type

TN-C0368SA0
TN-C0608SA0

TN-C0488SA0

Ducted Split Type


Economical and user-friendly model, designed for medium-sized houses
and shops. Features include a number of operation modes, auto restart and
a washable anti-bacterial filter.

LED Wired Remote Controller

Features
4way Convertibility-horizontal(Left & right), up-flow, down-flow Plastic drain Pan High efficient Evaporator Coil
Galvanized Steel with painting Washable and Anti-fungus Filter Multi-speed blower Time delay PCB
220V primary & 24V secondary transformer Defrost sensor Hi-Reliability Compressor Factory supplied charge of R-22
Compressor internal overload protection Internal pressure relief valve provides high pressure protection for compressor
Outside pressure taps for refrigerant system check.

Specification
Model

TN-C0368SA0

TN-C0488SA0

TN-C0608SA0

Capacity
Cooling (Gross)

Btu/hr

37,000

49,500

60,000

Heating

Btu/hr

Power Supply

,V,Hz

3, 380~415,50

3, 380~415,50

3, 380~415,50

M.C.A(with standard motor) Cooling / Heating

Amps

9.7

13.9

16.5

4,100

5,000

5,800

CMM

21.6

50.9

53.8

bell

6.2

6.2

Electrical Data

Power Input

Cooling / Heating

Performance
Air Circulation

Indoor

Sound Rating
Installation & Stuffing
Net Dimensions
(WxHxD)

Indoor

mm

470x1,014x480

600x1,135x500

600x1,135x500

Outdoor

mm

870x800x320

900x1,135x370

900x1,135x370

Net Weight

Indoor/Outdoor

Kg

59/65

63/100

65/115

Stuffing Quantity

Without S/Parts 20/40/40ft Hi

32/66/66

12/26/26

12/26/26

Note :Due to our policy of innovation some specifications may be changed without notification.

Air Filter Guide

Blower Housing Assembly

A Type Indoor Coil

Plastic Drain Pan

25

Ducted Split Type

TN-C0908T00

Ducted Split Type

TN-C1208T00

TN-C1508T00
TN-C2408T00

TN-C1808T00

Features

Features

Compact Size Quick and Easy Service Panels Anti-fungus, Hygienic and Easy-to-Clean filter
Convertible lnstallation Safety Condenser Fin Guard High/Low Static Driver Kit, Over Sized Motor(Accessory)
LCD Wired Remote Control

Compact Size Quick and Easy Service Panels Anti-fungus, Hygienic and Easy-to-Clean filter
Convertible lnstallation Safety Condenser Fin Guard High/Low Static Driver Kit, Over Sized Motor(Accessory)
LCD Wired Remote Control

Specification

Specification

Model

TN-C0908T00

TN-C1208T00

Capacity

Model

Cooling (Gross)

Btu/hr

80,900

111,200

Heating

Btu/hr

Electrical Data

Btu/hr

135,200

179,700

240,000

Btu/hr

Power Supply

,V,Hz

3, 380~415,50

3, 380~415,50

3, 380~415,50

M.C.A(with standard motor) Cooling / Heating

Amps

35

57.2

76.2

13,200

20,400

27,200

CMM

125

150

200

bell

8.0

8.0

8.0

Electrical Data
,V,Hz

3, 380~415,50

3, 380~415,50

Amps

20

30

8,100

11,800

CMM

76.4

102

Air Circulation

bell

6.0

6.3

Sound Rating

Cooling / Heating

Performance

Power Input

Cooling / Heating

Performance
Indoor

Sound Rating
Installation & Stuffing

Indoor

Installation & Stuffing

Net Dimensions
(WxHxD)

Indoor

mm

1,760x890x840

1,760x890x840

Outdoor

mm

855x1,570x740

1,330x1,570x740

Net Weight

Indoor/Outdoor

Kg

190/175

Stuffing Quantity

Without S/Parts 20/40/40ft Hi

6/15/22

Note :Due to our policy of innovation some specifications may be changed without notification.

26

TN-C2408T00

Heating

M.C.A(with standard motor) Cooling / Heating

Air Circulation

TN-C1808T00

Cooling (Gross)

Power Supply

Power Input

TN-C1508T00

Capacity

Net Dimensions
(WxHxD)

Indoor

mm

1,760x890x840

2,065x680x1,160

1,870x980x1,230

Outdoor

mm

1,130x1,180x1,100

1,640x1,130x880

1,840x1,130x970

190/300

Net Weight

Indoor/Outdoor

Kg

190/250

200/280

230/340

6/15/19

Stuffing Quantity

Without S/Parts 20/40/40ft Hi

7/14/19

7/14/19

7/14/19

Note :Due to our policy of innovation some specifications may be changed without notification.

27

LG AIR CONDITIONERS 2009

Fan Coil Unit

Slim & Compact Size

Fan Coil Unit

Durable & Energy Saving PCM Fin

The structures using CAD & CAE technology helps users reduce
installation spaces.
Slim and compact design based on CAD/CAE systems enables
user to reduce installation space.

The FCU (Fan Coil Unit) is supplied with cold or hot water by the control
center and circulates indoor air through the cooling and heating coils.

PCM Fin coated with anti corrosive & hydrophilic layers


prevents corrosion and make itself remains as like initial
condition, therefore it saves power & maintenance cost.
Heat Exchanger fins are coated with anticorrosive & hydrophilic
layers. It prevents the corrosion of heat exchanger. Fins remain
as new even after long time of operation and maintains
efficiency of heat exchanger constant.

260

230

The other companies (WxHxD):


1,020x260x515

Fan Coil Unit

LG (WxHxD):
1,090x230x524

LG PCM FIN

The other companies UNCOATED AL

Easy Maintenance
Easily removable motor & blower and removable panels help
users maintain units more conveniently.
Each unit is designed to occupy a minimum space. This feature,
along with convenient
wiring and piping connections, means reduces costs on
renovations or new construction
sites.
260
230

28
29

Fan Coil Unit

Fan Coil Unit

YBNC036ACA0 YBNC046BCA0
YBNC066CCA0 YBNC086DCA0
YBNC106ECA0 YBNC126FCA0
YBNC146GCA0

YBNC126HDA0 YBNC146JDA0
YBNC166KDA0 YBNC186KDA0
YBNC206DLA0

Features

Features

Washable Anti-bacteria Filter Easy Installation


Free Easy Air-Circulation Low Noise Level Easy Maintenance & Service
Additional Functions Available with Duct System District Cooling / Low Static

Washable Anti-bacteria Filter Easy Installation


Free Easy Air-Circulation Low Noise Level Easy Maintenance & Service
Additional Functions Available with Duct System District Cooling / HighStatic

Specification
Model

YBNC036ACA0

YBNC046BCA0

YBNC066CCA0

YBNC086DCA0

YBNC106ECA0

YBNC126FCA0

4 Rows Coil

Specification

YBNC146GCA0

Model

Performance
Nominial Air Flow

YBNC126HDA0

YBNC146JDA0

YBNC166KDA0

H/M/L

CFM
Btu/h

Water Flow Rate

GPM(US)

Water Pressure Drop

kPa / ft.wg.

416/354/283

508/424/341

640/512/430

869/736/577

1,100/924/742

1,242/1,048/848

1,422/1,195/948

10,130/9,144/6,960 14,252/11,874/9,519 17,783/15,968/12,590 24,921/22,656/17,640 28,893/25,999/21,530 35,089/31,970/25,624 38,150/35,280/28,217


1,320

1,850

2,270

3,190

3,650

4,460

4,840

3,740 / 1,227

7,590 / 2,490

11,540 / 3,785

12,050 / 3,952

13,920 / 4,566

17,550 / 5,756

30,330 / 9,948

32 / 35 / 40

28 / 34 / 40

35 / 40 / 43

35 / 40 / 44

35 / 40 / 44

37 / 41 / 45

38 / 43 / 48

Indoor Noise Level

Tube Size

dB(A)

H/M/L

CFM

1,348 / 1,115 / 1,051

1,513 / 1,338 / 1,196

1,702 / 1,562 / 1,296

1,901 / 1,674 / 1,428

2,089 / 1,928 / 1,638

Nominial Total Capacity H / M / L

Btu/h

37,028 / 31,455 / 28,123

43,099 / 36,650 / 32,745

47,219 / 41,558 / 37,474

51,088 / 45,105 / 39,659

55,530 / 47,889 / 41,737

Nominial Air Flow

Water Flow Rate (Middle)


Water Pressure Drop (Middle)

GPM(US)
kPa / ft.wg.

3,800

4,520

5,120

5,560

5,900

7,200 / 2,361

9,400 / 3,082

11,000 / 3,607

12,900 / 4,230

14,400 / 4,623

Face Area
Face Velocity

3 / 8 (9.52)

3 / 8 (9.52)

3 / 8 (9.52)

3 / 8 (9.52)

3 / 8 (9.52)

3 / 8 (9.52)

3 / 8 (9.52)

4R 8C 11FPI

4R 8C 11FPI

4R 8C 11FPI

4R 8C 11FPI

4R 8C 11FPI

4R 8C 11FPI

4R 8C 11FPI

sq.m

0.122

0.142

0.189

0.244

0.284

0.325

0.345

Face Area

m/s

1.61

1.69

1.60

1.68

1.83

1.80

1.95

Face Velocity

inch(mm)

Motor
3 - Speed Permanent Split Capacitor Motor
#

Class
Power Supply
Total Rating Input

dB(A)

50 / 53 / 59

51 / 55 / 60

49 / 55 / 59

51 / 57 / 59

53 / 58 / 62

3 / 8 (9.52)

3 / 8 (9.52)

3 / 8 (9.52)

3 / 8 (9.52)

3 / 8 (9.52)

4R 12C 13FPI

4R 12C 13FPI

4R 12C 13FPI

4R 12C 13FPI

4R 12C 13FPI

sq.m

0.237

0.274

0.329

0.329

0.411

m/s

2.39

2.41

2.29

2.59

2.30

1 / 50 / 220~240

1 / 50 / 220~240

1 / 50 / 220~240

1 / 50 / 220~240

1 / 50 / 220~240

330

440

480

550

650

inch(mm)

No. of Rows, Columns & FPI

Ph/Hz/V
watt

3 - Speed Permanent Split Capacitor Motor

Type

No. of motor

Class

1 / 50 / 220~240

1 / 50 / 220~240

1 / 50 / 220~240

1 / 50 / 220~240

1 / 50 / 220~240

1 / 50 / 220~240

1 / 50 / 220~240

67

75

102

152

188

198

280

Power Supply
Total Rating Input (Middle)

Ph/Hz/V
watt

Fan
Galvanized Steel

Material

Galvanized Steel

Material

Centrifugal Fan (Forward Curve)

Type

Centrifugal Fan (Forward Curve)

Type

Water Content
3 Rows

Tube Size

Fan

No. of Fans

L / M /H

Motor

Type
No. of motor

Noise Level
Coil

No. of Rows, Columns & FPI

No. of Fans

2.66

3.01

3.07

3.07

3.80

Water Content
Liter

1.183

1.381

1.834

2.366

2.761

3.155

3.352

Drain Pan

3 Rows

Liter

Drain Pan

Drain Pan (Material / Thickness)

Galvanized Steel / T0.8

Drain Pan (Material / Thickness)

Galvanized Steel / T0.8

Insulator (Meterial / Thickness)

PE / T5.0

Insulator (Meterial / Thickness)

PE / T5.0

Filter

Filter
Synthetic Nylon (optional Aluminum)

Material

Note :Due to our policy of innovation some specifications may be changed without notification.

30

YBNC206DLA0

Indoor Noise Level


L / M /H

Coil

No. of Filter

YBNC186KDA0

Performance

Nominial Total Capacity H / M / L

Noise Level

4 Rows Coil

Synthetic Nylon (optional Aluminum)

Material

No. of Filter

Note :Due to our policy of innovation some specifications may be changed without notification.

31

Fan Coil Unit

Fan Coil Unit

YBNB036AAA0 YBNB046BAA0
YBNB066CAA0 YBNB086DAA0
YBNB106EAA0 YBNB126FAA0
YBNB146GAA0

YBNB126HBA0 YBNB146JBA0
YBNB166KBA0 YBNB186KBA0
YBNB206LBA0

Features

Features

Washable Anti-bacteria Filter Easy Installation


Free Easy Air-Circulation Low Noise Level Easy Maintenance & Service
Additional Functions Available with Duct System Standard / Low Static

Washable Anti-bacteria Filter Easy Installation


Free Easy Air-Circulation Low Noise Level Easy Maintenance & Service
Additional Functions Available with Duct System Standard / High Static

Specification
Model

YBNB036AAA0

YBNB046BAA0

YBNB066CAA0

YBNB086DAA0

YBNB106EAA0

YBNB126FAA0

3 Rows Coil

Specification

YBNB146GAA0

Model

Performance
Nominial Air Flow

YBNB126HBA0

YBNB146JBA0

YBNB166KBA0

H/M/L

CFM
Btu/h

Water Flow Rate

GPM(US)

Water Pressure Drop

kPa / ft.wg.

306/253/200

432/379/329

686/570/484

859/765/647

1,059/946/812

1,182/1,053/929

1,728/1,270/1,082

12,249/11,294/8,803 14,876/13,898/10,884 21,905/19,790/15,968 27,637/24,839/21,018 31,049/28,490/24,566 37,805/34,188/28,081 48,621/43,947/37,020


2,780

3,400

5,000

6,210

7,040

8,510

10,990

4,950 / 1,624

6,070 / 1,991

16,300 / 5,346

20,510 / 6,727

26,630 / 8,735

28,840 / 9,460

31,070 / 10,191

32 / 35 / 40

28 / 33 / 40

35 / 39 / 42

35 / 39 / 42

35 / 40 / 44

37 / 41 / 45

37 / 43 / 48

Indoor Noise Level

Tube Size

dB(A)

H/M/L

CFM

1,238 / 1,052 / 941

1,441 / 1,225 / 1,095

1,594 / 1,403 / 1,265

1,803 /1,591/ 1,400

2,006 / 1,759 / 1,548

Nominial Total Capacity H / M / L

Btu/h

38,385 / 33,642 / 29,173

43,844 / 37,123 / 33,608

47,086 / 41,285 / 37,941

49,815 / 43,674 / 38,556

56,639 / 49,815 / 42,991

Nominial Air Flow

Water Flow Rate

GPM(US)

Water Pressure Drop

kPa / ft.wg.

8,640

9,890

10,700

11,400

12,990

21,920 / 7,190

24,810 / 8,138

28,040 / 9,197

34,040 / 11,165

38,300 / 12,562

Face Area
Face Velocity

3 / 8 (9.52)

3 / 8 (9.52)

3 / 8 (9.52)

3 / 8 (9.52)

3 / 8 (9.52)

3 / 8 (9.52)

3 / 8 (9.52)

3R 8C 11FPI

3R 8C 11FPI

3R 8C 11FPI

3R 8C 11FPI

3R 8C 11FPI

3R 8C 11FPI

3R 8C 11FPI

sq.m

0.122

0.142

0.189

0.244

0.284

0.325

0.345

Face Area

m/s

1.18

1.47

1.70

1.69

1.69

1.80

1.97

Face Velocity

inch(mm)

Motor
3 - Speed Permanent Split Capacitor Motor
#

Class
Power Supply
Total Rating Input

dB(A)

44 / 48 / 52

46 / 49 / 54

47 / 52 / 56

49 / 54 / 57

51 / 55 / 59

3 / 8 (9.52)

3 / 8 (9.52)

3 / 8 (9.52)

3 / 8 (9.52)

3 / 8 (9.52)

3R 12C 13FPI

3R 12C 13FPI

3R 12C 13FPI

3R 12C 13FPI

3R 12C 13FPI

sq.m

0.237

0.274

0.329

0.329

0.411

m/s

2.47

2.48

2.29

2.59

2.30

1 / 50 / 220~240

1 / 50 / 220~240

1 / 50 / 220~240

1 / 50 / 220~240

1 / 50 / 220~240

334

396

428

517

710

inch(mm)

No. of Rows, Columns & FPI

Ph/Hz/V
watt

3 - Speed Permanent Split Capacitor Motor

Type

No. of motor

Class

1 / 50 / 220~240

1 / 50 / 220~240

1 / 50 / 220~240

1 / 50 / 220~240

1 / 50 / 220~240

1 / 50 / 220~240

1 / 50 / 220~240

60

70

97

148

178

182

250

Power Supply
Total Rating Input

Ph/Hz/V
watt

Fan
Galvanized Steel

Material

Galvanized Steel

Material

Centrifugal Fan (Forward Curve)

Type

Centrifugal Fan (Forward Curve)

Type

Water Content
3 Rows

Tube Size

Fan

No. of Fans

L / M /H

Motor

Type
No. of motor

Noise Level
Coil

No. of Rows, Columns & FPI

No. of Fans

1.99

2.18

2.30

2.30

2.85

Water Content
Liter

0.887

1.036

1.376

1.775

2.071

2.366

2.514

Drain Pan

3 Rows

Liter

Drain Pan

Drain Pan (Material / Thickness)

Galvanized Steel / T0.8

Drain Pan (Material / Thickness)

Galvanized Steel / T0.8

Insulator (Meterial / Thickness)

PE / T5.0

Insulator (Meterial / Thickness)

PE / T5.0

Filter

Filter
Synthetic Nylon (optional Aluminum)

Material

Note :Due to our policy of innovation some specifications may be changed without notification.

32

YBNB206LBA0

Indoor Noise Level


L / M /H

Coil

No. of Filter

YBNB186KBA0

Performance

Nominial Total Capacity H / M / L

Noise Level

4 Rows Coil

Synthetic Nylon (optional Aluminum)

Material

No. of Filter

Note :Due to our policy of innovation some specifications may be changed without notification.

33

Fan Coil Unit

Fan Coil Unit

YBNC126HBA0 YBNC146JBA0
YBNC166KBA0

YBNC186KBA0 YBNC206LBA0

Features

Features

Washable Anti-bacteria Filter Easy Installation


Free Easy Air-Circulation Low Noise Level Easy Maintenance & Service
Additional Functions Available with Duct System Standard / High Static

Washable Anti-bacteria Filter Easy Installation


Free Easy Air-Circulation Low Noise Level Easy Maintenance & Service
Additional Functions Available with Duct System Standard / High Static

4 Rows Coil

Specification
Model

YBNC126HBA0

YBNC146JBA0

YBNC166KBA0

Performance
H/M/L

CFM

1,348 / 1,115 / 1,051

1,513 / 1,338 / 1,196

1,702 / 1,562 / 1,296

Btu/h

44,066 / 38,764 / 33,927

53,022 / 46,645 / 40,842

56,713 / 50,873 / 46,072

Water Flow Rate (Middle)


Water Pressure Drop (Middle)

GPM(US)
kPa / ft.wg.

8,600

10,340

11,280

28,300 / 9,279

30,000 / 9,836

31,800 / 10,426

50 / 53 / 59

51 / 55 / 60

49 / 55 / 59

Indoor Noise Level


Noise Level

Model

YBNC186KBA0

YBNC206LBA0

Performance

Nominial Total Capacity H / M / L

Nominial Air Flow

4 Rows Coil

Specification

H/M/L

CFM

1,901 / 1,674 / 1,428

2,089 / 1,928 / 1,638

Nominial Total Capacity H / M / L

Btu/h

63,412 / 54,814 / 47,326

73,802 / 64,129 / 54,814

Nominial Air Flow

Water Flow Rate (Middle)


Water Pressure Drop (Middle)

GPM(US)
kPa / ft.wg.

12,160

14,220

36,500 / 11,967

54,100 / 17,738

51 / 57 / 59

53 / 58 / 62

Indoor Noise Level


L / M /H

dB(A)

Coil
Tube Size

Face Velocity

3/8 (9.52)

3/8 (9.52)

3/8 (9.52)

4R 12C 13FPI

4R 12C 13FPI

4R 12C 13FPI

sq.m

0.237

0.274

0.274

Face Area

m/s

2.39

2.41

2.41

Face Velocity

inch(mm)

Motor
3 - Speed Permanent Split Capacitor Motor
#

Class
Power Supply
Total Rating Input (Middle)

3/8 (9.52)

3/8 (9.52)

4R 12C 13FPI

4R 12C 13FPI

sq.m

0.329

0.411

m/s

2.59

2.30

inch(mm)

No. of Rows, Columns & FPI

Ph/Hz/V
watt

3 - Speed Permanent Split Capacitor Motor

Type

No. of motor

Class

1/50/220~240

1/50/220~240

1/50/220~240

330

440

480

Power Supply
Total Rating Input (Middle)

Ph/Hz/V
watt

1/50/220~240

1/50/220~240

550

650

Fan
Galvanized Steel

Material

Galvanized Steel

Material

Centrifugal Fan (Forward Curve)

Type

Centrifugal Fan (Forward Curve)

Type

Water Content
3 Rows

Tube Size

Fan

No. of Fans

dB(A)

Motor

Type
No. of motor

L / M /H

Coil

No. of Rows, Columns & FPI


Face Area

Noise Level

No. of Fans

3.07

3.80

Water Content
Liter

2.66

3.01

3.01

Drain Pan

3 Rows

Liter

Drain Pan

Drain Pan (Material / Thickness)

Galvanized Steel / T0.8

Drain Pan (Material / Thickness)

Galvanized Steel / T0.8

Insulator (Meterial / Thickness)

PE / T5.0

Insulator (Meterial / Thickness)

PE / T5.0

Filter

Filter
Synthetic Nylon (optional Aluminum)

Material
No. of Filter

Note :Due to our policy of innovation some specifications may be changed without notification.

34

Synthetic Nylon (optional Aluminum)

Material

No. of Filter

Note :Due to our policy of innovation some specifications may be changed without notification.

35

LG AIR CONDITIONERS 2009

Multi Mdx are freely interchangeable multi systems with


MPS-controlled, constant speed compressors.
These systems are perfectly suited for tropical conditions.

Multi Mdx are freely interchangeable multi systems with MPS-controlled, constant speed
compressors. These systems are perfectly suited for tropical conditions.

MULTI

M DX
36
37

LG AIR CONDITIONERS 2009

are freely interchangeable multi systems with MPS-controlled, constant speed


compressors. These systems are perfectly suited for tropical conditions.

Tropical MPS Multi System Installation


Next Generation LG MPS Tropical Multi System

Outdoor Unit Line-up


MPS Variable System
- High efficiency
- High reliability
- Long piping & high elevation flexibility
- Max.8 indoor units by simple piping
- Low noise
- Central control

L4UC608FA2

L5UC728FA3
L6UH728FA2

L8UC1008FA3
L8UC1008FA2
L8UC1508FA1

Single Piping Type


* Made in Thailand

Indoor Unit Line-up


Btu/h

12K

18K

24K

30K

48K

36K

*Metal

*White Wood

*Blue

*Cherry

M DX

Wall-Mounted

MULTI

Type

Color variable

ARTCOOL Mirror

High Staic Duct

MPS Variable Control is LGs unique, energy-saving control technology,


which is applied in both the Multi MDX series.

38
39

Low Staic Duct

4-Way Cassette

LG AIR CONDITIONERS 2009

Tropical MPS Multi System Installation


Next Generation LG MPS Tropical Multi System

Tropical MPS Multi System Solutions

Small Office Building

Residential Building

MULTI

M DX
40
41

For Commercial Sites

Small Office

For Residential Sites

Small Shop

Restaurant

Resort

Apartment

Villa

LG AIR CONDITIONERS 2009

Tropical MPS Multi System Installation


Next Generation LG MPS Tropical Multi System

Energy Saving with Tropical MPS Variable Control


Basic Principle of Tropical MPS Variable Control

Long Distance & High Elevation Piping

The Tropical MPS (multi power system) control two or more constant speed compressors, a hot gas bypass circuit and an linear
expansion valve (LEV). With multiple compressors operating according to increasing cooling requirements, considerable amounts of
energy can be saved. In case of a low cooling load, only one compressor will operate. When the cooling load increases, both
compressors will operate and balance the load.

Long Distance &


High Elevation Piping:
Max. Pipe Length:
110m/cycle

The finely tuned refrigerant return ratio and special accumulator


allow piping lengths of up to 110m at a max. elevation of 45m. The
runback returns refrigerant to the compressor to maintain a safe
level of refrigerant at all times. It allows better flexibility for
installation under difficult structural conditions.

100%
50%
Conventional system (On/Off Operation)

50%
MPS Variable Control

Simple & Cutting Edge Control System

M DX

MPS Variable Multi system opeates in one cycle with two compressors. Only one compressor or two compressors run together,
according to the load conditions.With small load. only one compressor completes the cycle. It saves power consumption at low
operation. This concept is explained in the picture below.

MULTI

Power Consumption Comparison

- Please Refer to Page 64

Tropical Compressor Technology

42
The Tropical compressor is highly reliable, even under extreme
conditions (15~60C average), sandstorms and 24 hour
operation. At extreme temperatures over 54C only 1 large
compressor operates to protect the smaller compressors and to
prevent the indoor temperature from rising due to repeated OLP
triggering.

BLDC Fan
BLDC fan motor offers additional energy saving in operating mode. Compared with AC motors, BLDC fan motor can cut energy by
35%at full velocity. AC motor is operating at full velocity only, but BLDC Motor can change velocity according to load. Energy efficiency
levels at low velocities in particular have been improved by 65%.

Max Press.(kgf/cm2)
Td (C)
Under voltage
Noise

Standard

Tropical

28

33

110

115

10%

15%

New Design -muffle -resonator

INCREASED RELIABILITY
- Overload Protector
- High Torque Motor
- Special Anti-Wear Coating
- High Rigidity Crank Shaft

43

LG AIR CONDITIONERS 2009

Flexible Design & Simple Piping

Tropical MPS Multi System Installation


Next Generation LG MPS Tropical Multi System

Distributor Type

The Tropical MPS Multi allows simple piping for easy installation by using branch distributors.

The MPS Variable multi system uses a simple refrigerant pipe to connect one outdoor unit with multiple indoor units.
It is easy to install and very economical.
Various distributors for flexible design

A,B : Main piping


L1,L2,L3,L4,L5,L6,L7,L8 : Branch piping
The specifications above are only for two models,
L8UC1008FA3/L8UC1508FA1.
Please refer to the Product Data Book for other models.

Connecting distributor without brazing

L1
L2

Indoor Unit
L3

L1

Outdoor Unit
(L8UC1008FA3)

L2

Installation of
outdoor unit
in lower position

Branch Distributor
L3

Installation of
the outdoor unit
in an upper
position

For 2 Room

For 3 Room

For 4 Room

Branch Distributor

L5

45m

L5

L4
B

L4

L6

45m

L7
A

L6

Branch Distributor

L8

Branch Distributor
L7

Indoor Unit

Outdoor Unit
(L8UC1008FA3)

L8

Direct Connection Type


Piping length : 50m(A), 50m(B) Total system piping length : 100m(50+50)
(Please refer to PDB for detail piping spec.)

MULTI

Total main piping length : 50m(A), 50m(B) With L5UC728FA3, L8UC1008FA3, L8UC150FA1
Total branch piping length : 60m(L1+L2+L3+L4), 60m(L5+L6+L7+L8)
Maximum length of single branch piping: 15m(L1, L2, L3,L4, L5, L6, L7, L8)
Total system piping length: 220m = 110m(A+L1+L2+L3+L4)+110m(B+L5+L6+L7+L8)
Maximum elevation from outdoor unit to indoor unit : 45m with L5UC728FA3, L8UC1008FA3, L8UC150FA1

M DX

Indoor Unit

Easy installation with various distributors


B

Unit

Indoor Unit

Indoor Unit

Outdoor Unit
(L8UC1008FA3)

PMBD5420L

PMBD5430L

PMBD5440L

2 indoors

3 indoors

4 indoors

1~2
10
0.05
300 x 150 x 250
4.8
9.52 / 19.05
6.35x2 / 12.7x2

1~3
10
0.05
300 x 150 x 250
4.9
9.52 / 19.05
6.35x3 / 12.7x3

1~4
10
0.05
300 x 150 x 250
5.0
9.52 / 19.05
6.35x4 / 12.7x4

Distributor
45m

45m

Indoor Unit

Short Tube
Installation of outdoor unit in an elevated position

Outdoor Unit
(L8UC1008FA3)

For

Installation of outdoor unit in a lower position

Connectable indoor Unit


Power Consumption
Running Current
Net Dimensions
Net Weight
Piping Connection (Outdoor Unit)
Piping Connection (Indoor Unit)

Type
(WxHxD)
Liquid / Gas
Liquid / Gas

(W)
(A)
(mm)
(kg)
(mm)
(mm)

A variety of distributors makes installation on any site much easier.


Notes: 1.BD unit BD unit, Indoor Unit Indoor Unit : Max. Height - 10m Set up the BD unit and Indoor Unit in 15m.
2. Piping connectors must fit the piping sizes of the indoor unit to be connected.(If required, use the connector which is included with the indoor unit.)
3. The BD unit should be installed inside the building.

Various Combination
4 Room Type

5~6 Room Type

8 Room Type

Short Tube

Y Branch

Use short tube in case of connecting 48K indoor unit to outdoor unit(direct piping)
For detailed usage of short tube and Y-branch, please refer to PDB

44
45

L4UC608FA2 / L5UC728FA3 / L6UH728FA2

Specification
HP
Nomal Capacity
(Min~Rating)

Cooling
Heating

Nominal Input
(Min~Rating)
Running Current

Cooling
Heating
Cooling
Heating
Cooling/Heating

Starting Current
Power Supply
Power Supply Cable (outdoor)
Power and transmission cable(outdoor to BD)
Power and transmission cable(BD to indoor)
Dimensions
W*H*D
Net Weight
Max. Number of Connectable indoor Units
Compressor
Type
constant speed
Qty x Model
(A+B)
Motor Type
(MPS cycle 1)
Oil Type
Oil Charge
Compressor
Type
constant speed
Qty x Model
(C or C+D)
Motor Type
(Single or MPS cycle 2) Oil Type
Oil Charge
Refrigerant
Charge (at 7.5m)
Type
Control

Specification
kW
Btu/h
kW
Btu/h
kW
kW
A
A
A
, V, Hz
No.*mm2
No.*mm2
No.*mm2
mm(inch)
kg(Ibs)

cc

cc
g(oz)
EEV

Short tube
(Row x Column x FPI)*No.
Defrosting Method
Fan motor
Capacitor
F/Vac
Drive
Discharge direction
Side/Top
Air Flow Rate x No.of fan
CMM(cfm)
Noise Level (H/L)
Sound Pressure at 1m
dB(A)+3
Piping connections Liquid()(Circuit 1)
mm(inch)
Gas()(Circuit 1)
Liquid()(Circuit 2)
Gas()(Circuit 2)
Max.total Piping
m
BD
Max. OD~BD Piping
m
MPS Piping
Multi
Max. total sum of BD~ID Piping
m
MDx
Direct Piping Max. OD~ID Piping
m
Single
Max. OD~ID Piping
m
Max. Elevation
Indoor Unit~Outdoor Unit
m
Difference
Indoor Unit~Indoor Unit
m
Heat Exchanger

Notes:

46

L8UC1008FA3 / L8UH1008FA2 / L8UC1508FA1

L4UC608FA2
5.3~17.6
18,000~60,000
2.9~5.7
5.3~10.2
24
3, 380~415, 50
5 * 50 (includes earth)
4 * 0.75 (includes earth)
4 * 0.75 (includes earth)
900*1,165*370 (35.4*45.8*14.5)
104 (230)
4
Twin Rotary
2 x QPT525YAB
3 Phase Induction
SUNISO NM56
1,200
3,400 (120)
R22
MPS cycle EEV In BD unit
Single cycle EEV in outdoor unit
(2R x 26C x 18) * 2
6/370~400
Direct drive
side
80 (2,824) x 1
60
9.52 (3/8)
19.05 (3/4)
60
30
30
30
10

1. Capacities are based on the following conditions:


Cooling: - Indoor Temperature 27C(80.6F) DB /19C(66.2F) WB
- Outdoor Temperature 35C(95F) DB /24C(75.2F) WB
Heating: - Indoor Temperature 20C(68F) DB /15C(59F) WB
- Outdoor Temperature 7C(44.6F) DB /6C(42.8F) WB
Piping Length: - Interconnecting Piping Length 7.5m
- Level Difference of Zero.
2. At least two indoor units should be connected.

L5UC728FA3
3.5~21.1
12,000~72,000
1.9~6.8
3.8~12.3
24
3, 380~415, 50
5 * 5.0 (includes earth)
4 * 0.75 (includes earth)
4 * 0.75 (includes earth)
806*1,607*730(31.7*63.3*28.7)
205 (452)
5
Rotary
2 x QPT425Y
3 Phase Induction
ATMOS M60/SUNISO 4GSI
1,130
Rotary
1 x QP425Y
3 Phase Induction
ATMOS M60/SUNISO 4GSI
1,130

L6UH728FA2
3.5~21.1
12,000~72,000
3.5~21.1
12,000~72,000
2.2~7.3
2.8~7.2
4.9~14.7
4.8~14.5
24
3, 380~415, 50
5 * 5.0 (includes earth)
4 * 0.75 (includes earth)
4 * 0.75 (includes earth)
806*1,607*730(31.7*63.3*28.7)
190 (419)
6
Twin Rotary
2 x QPT425YAB
3 Phase Induction
ATMOS M60/SUNISO 4GSI
1,200
Twin Rotary
1 x QP425YAB
3 Phase Induction
ATMOS M60/SUNISO 4GSI
1,200

Cycle 1: 4600(162.21)/Cycle 2:2300(81.1)

Cycle 1: 4000(141)/Cycle 2:2000(70.5)

R22
MPS cycle EEV In BD unit
Single cycle EEV in outdoor unit
(079 / - / 079)
(2Rx17Cx18)*2+(2Rx36Cx18)*2
10/370
Direct drive
top
90 (3,179) x 1
60
9.52 (3/8)
19.05 (3/4)
6.35 (1/4)
15.88 (5/8)
110
50
60
50
50
45
10

R22
MPS cycle EEV In BD unit
Single cycle EEV in outdoor unit
(079 / - / 079), (085 / - / 096)
(2Rx17Cx18)*2+(2Rx36Cx18)*2
Reverse cycle
10/450
Direct drive
top
90 (3179) x 1
60
9.52 (3/8)
19.05 (3/4)
6.35 (1/4)
15.88 (5/8)
Cycle1:60 / Cycle2:45
Cycle1:30 / Cycle2:30
Cycle1:30 / Cycle2:15
Cycle1:50 / Cycle2: 30
10

HP
Nomal Capacity
(Min~Rating)

Cooling
Heating

Nominal Input
(Min~Rating)
Running Current

Cooling
Heating
Cooling
Heating
Cooling/Heating

Starting Current
Power Supply
Power Supply Cable (outdoor)
Power and transmission cable(outdoor to BD)
Power and transmission cable(BD to indoor)
Dimensions
W*H*D
Net Weight
Max. Number of Connectable indoor Units
Compressor
Type
constant speed
Qty x Model
(A+B)
Motor Type
(MPS cycle 1)
Oil Type
Oil Charge
Compressor
Type
constant speed
Qty x Model
(C or C+D)
Motor Type
(Single or MPS cycle 2) Oil Type
Oil Charge
Refrigerant
Charge (at 7.5m)
Type
Control
Heat Exchanger

kW
Btu/h
kW
Btu/h
kW
kW
A
A
A
, V, Hz
No.*mm2
No.*mm2
No.*mm2
mm(inch)
kg(Ibs)

cc

cc
g(oz)

EEV
Short tube
(Row x Column x FPI)*No.

Defrosting Method
Capacitor
F/Vac
Drive
Discharge direction
Side/Top
Air Flow Rate x No.of fan
CMM(cfm)
Noise Level (H/L)
Sound Pressure at 1m
dB(A)+3
Piping connections Liquid()(Circuit 1)
mm(inch)
Gas()(Circuit 1)
Liquid()(Circuit 2)
Gas()(Circuit 2)
Max.total Piping
m
BD
m
Piping Max. OD~BD Piping
Piping Multi MPS
Max. total sum of BD~ID Piping
m
MDx
Direct Piping Max. OD~ID Piping
length
m
spec.
Max. total Piping
m
Multi M
Max. OD~ID Piping
m
Max. Elevation
Indoor Unit~Outdoor Unit
m
Difference
Indoor Unit~Indoor Unit
m
Fan motor

Notes:

L8UC1008FA3
3.5~29.3
12,000~100,000
--1.6~9.9
-3.4~21.8
--3, 380~415, 50
5 * 5.0 (includes earth)
4 * 0.75 (includes earth)
4 * 0.75 (includes earth)
1,280*1,607*730(50.4*63.3*28.7)
250 (551)
8
Rotary
2 x QP425Y
3 Phase Induction
ATMOS M60/SUNISO 4GSI
1130
Rotary
2 x QP425Y
3 Phase Induction
ATMOS M60/SUNISO 4GSI
1130
4000(141.1)
R22
2 MPS cycle EEV In BD unit
(079 / - / 079), (085 / - / 096)
(2R x 14C x 18)*2 +
(1R x 30C x 18)*2
-10/370
Direct drive
top
90 (3179) x 2
60
9.52 (3/8)
19.05 (3/4)
9.52 (3/8)
19.05 (3/4)
110
50
60
50
--45
10

L8UH1008FA2
3.5~29.3
12,000~100,000
3.5~29.3
12,000~100,000
1.6~9.9
2.3~9.0
3.4~21.8
4.2~16.0
-3, 380~415, 50
5 * 5.0 (includes earth)
4 * 0.75 (includes earth)
4 * 0.75 (includes earth)
1,280*1,607*730(50.4*63.3*28.7)
250 (551)
8
Rotary
2 x QP425Y
3 Phase Induction
ATMOS M60/SUNISO 4GSI
700
Rotary
2 x QP425Y
3 Phase Induction
ATMOS M60/SUNISO 4GSI
700
4000(141.1)
R22
2 MPS cycles EEV in BD unit
(079 / - / 079), (085 / - / 096)
(2R x 14C x 18)*2 +
(1R x 30C x 18)*2
Reverse cycle
10/370
Direct drive
top
90 (3179) x 2
60
9.52 (3/8)
19.05 (3/4)
9.52 (3/8)
19.05 (3/4)
60
30
30
50
--30
10

L8UC1508FA1
5.3~44.0
18,000~150,000
--3.5~16.3
-6.39~29.1
--3, 380~415, 50
5 * 8.4 (includes earth)
4 * 0.75 (includes earth)
4 * 0.75 (includes earth)
1,280*1,607*730(50.4*63.3*28.7)
320 (661)
8
Twin Rotary
3 x QPT525Y
3 Phase Induction
SUNISO NM56
1200
Twin Rotary
2 x QPT525Y
3 Phase Induction
SUNISO NM56
1200
Cycle1:7200(254)/Cycle2:4800(169)
R22
2 MPS cycles EEV in BD unit
(2Rx14Cx18)*2+(2Rx30C x18)*1
+(3Rx30Cx18)*1
-10/370
Direct drive
top
180 (6357)
60
12.7 (1/2)
25.4 (1)
9.52 (3/8)
19.05 (3/4)
110
50
60
---45
10

1. Capacities are based on the following conditions:


Cooling: - Indoor Temperature 27C(80.6F) DB /19C(66.2F) WB
- Outdoor Temperature 35C(95F) DB /24C(75.2F) WB
Heating: - Indoor Temperature 20C(68F) DB /15C(59F) WB
- Outdoor Temperature 7C(44.6F) DB /6C(42.8F) WB
Piping Length: - Interconnecting Piping Length 7.5m
- Level Difference of Zero.
2. At least two indoor units should be connected.
3. Wiring cable size must comply with the applicable local and national code.
4. The specification may be subject to change without prior notice for purpose of improvement.

47

Combination of Indoor and Outdoor Unit


Combination Table

L4UC608FA2
L5UC728FA3

L4UC608FA2
Cooling
Operation

Combination of Indoor unit(k Btu/h)


Capacity (Btu/h)

Unit
Outdoor Units
Indoor Units

L4UC608FA2

L5UC728FA3

L6UH728FA2

L8UC1008FA3
L8UH1008FA2

L8UC1508FA1

1 unit

Number of Connectible Indoor Units

Capacity
Model Type

Wall Mounted

General

ARTCOOL

Mirror

Ceiling Cassette

4 Way

Hight Static

Ceiling Concealed
Duct
Low Static

Index

Btu/h

kW

up to 4

up to 5

up to 6

up to 8

up to 8

12
18
24
12
18
24
12
18
24
30
36
48
18
24
30
36
48
12
18
24

12,000
18,000
24,000
12,000
18,500
24,000
12,000
18,000
24,000
30,000
36,000
48,000
18,000
24,000
30,000
36,000
48,000
12,000
18,000
24,000

3.52
5.28
7.03
3.52
5.42
7.03
3.2
5.28
7.03
8.79
10.55
14.07
5.28
7.03
8.79
10.55
14.07
3.52
5.28
7.03

2 units

3 units

4 units

Unit-A Unit-B Unit-C Unit-D


18
24
30
36
48
18
18
18
18
18
24
24
24
30
30
18
18
18
18
24
18

18
24
30
36
48
30
36
48
30
36
18
18
18
18
24
18

18
24
30
36
24
18

18

Total

Unit-A

Unit-B

Unit-C

Unit-D

Total

18
24
30
36
48
36
42
48
54
66
54
60
72
60
66
54
60
66
72
72
72

18000
24000
30000
36000
48000
18000
18000
18000
18000
16000
24000
24000
20000
30000
28000
18000
18000
16000
15000
20000
15000

18000
24000
30000
36000
44000
30000
36000
40000
30000
34000
18000
18000
16000
15000
20000
15000

18000
23000
28000
30000
20000
15000

15000

18000
24000
30000
36000
48000
36000
42000
48000
54000
60000
54000
60000
60000
60000
62000
54000
59000
60000
60000
60000
60000

Input (W)

Current (A)

2850
2850
3000
5600
6050
5600
5600
6050
5800
6300
6300
6300
6300
6300
6300
5800
5700
6300
6300
5800
5900

5.3
5.3
5.5
9.0
9.2
9.0
9.2
9.6
9.6
9.8
9.6
9.6
10.2
9.6
9.6
10.2
10.2
9.6
9.6
10.2
10.6

Input (W)

Current (A)

4600
4250
4250
4250
4600
4600
4600
4600
4100
4100
4250
4250
4250
4250
4250
4250
4250
2450

8.2
8.0
8.0
8.0
8.2
8.2
8.2
8.2
7.8
7.8
8.0
8.0
8.0
8.0
8.0
8.0
8.0
4.5

Notes:
1. Cooling Capacity is based on : indoor temp.27C(80.6F) DB, 19C(66.2F) WB; outdoor temp. 35C(95F) DB
2. The total capacity of indoor unit of "Circuit 1" is up to 36000 Btu/h (10.6kW). The total capacity of indoor unit of "Circuit 2" is up to 24000 Btu/h (7.1kW).
3. The capacity is based on standard length of interconnecting refrigerant line. [Standard length : Direct Piping - 7.5m (25ft), Distributor Piping - Main 5m(16.4ft), Branch 7.5m (25ft)]

Notes:
1. The total capacity index of indoor units is the of capacity index of eachunits and shoul be within the maximum capacity index of the outdoor unit.

L5UC728FA3
Cooling
Operation

Combination of Indoor units (k Btu/h)


Capacity (Btu/h)

Circuit Unit

1 unit

2 units

3 units

4 units
2

1 unit

Unit-A Unit-B Unit-C Unit-D


48
12
18
18
18
18
24
24
12
12
12
12
12
12
18
12
12
24

36
18
24
30
36
30
24
12
12
12
12
18
18
18
12
12
-

12
18
24
30
18
24
18
12
12
-

12
18
-

Total

Unit-A

Unit-B

Unit-C

Unit-D

Total

48
48
36
42
48
54
54
48
36
42
48
54
48
54
54
48
54
24

48000
12000
18000
18000
18000
16000
22000
24000
12000
12000
12000
11110
12000
11110
16670
12000
11000
24000

36000
18000
24000
30000
34000
28000
24000
12000
12000
12000
11110
18000
16670
16670
12000
11000
-

12000
18000
24000
27780
18000
22220
16670
12000
11000
-

12000
17000
-

48000
48000
36000
42000
48000
50000
50000
48000
36000
42000
48000
50000
48000
50000
50000
48000
50000
24000

Notes:
1. Cooling Capacity is based on : indoor temp.27C(80.6F) DB, 19C(66.2F) WB; outdoor temp. 35C(95F) DB
2. The maximum capacity available for this model is 54k Btu/hr (15.8kW).
3. The capacity is based on standard length of interconnecting refrigerant line.
4. The number of indoor units that can be installed is from 2 to 4. Below 2 indoor units, installation is not possible.
5. In case of the maximum capacity combinations of indoor unit the capacity might seem to be decreased due to the changes in discharge temperature of indoor units, while the total capacity(i.e. the total sum of
indoor units capacity) is to be slightly increased with increasing air flow rate of indoor units with respect to the overall system.

48

49

Combination Table

Combination Table

L6UH728FA2

L6UH728FA2

L8UC1008FA3, L8UH1008FA2

L8UC1008FA3, L8UH1008FA2
Cooling / Heating

Operation

Cooling / Heating

Combination of Indoor unit(k Btu/h)

Operation

Capacity (Btu/h)
Input (W)
Circuit Unit

1 unit

2 units

3 units

4 units
2

1 unit
2 unit

Unit-A Unit-B Unit-C Unit-D


48
12
18
18
18
18
24
24
12
12
12
12
12
12
18
12
12
24
12

36
18
24
30
36
30
24
12
12
12
12
18
18
18
12
12
12

12
18
24
30
18
24
18
12
12
-

12
18
-

Total

Unit-A

Unit-B

48
48
36
42
48
54
54
48
36
42
48
54
48
54
54
48
54
24
24

48000 / 48000
12000 / 12000
18000 / 18000
18000 / 18000
18000 / 18000
16000 / 16000
22000 / 22000
24000 / 24000
12000 / 12000
12000 / 12000
12000 / 12000
11110 / 11110
12000 / 12000
11110 / 11110
16670 / 16670
12000 / 12000
11000 / 11000
24000 / 24000
12000 / 12000

-/36000 / 36000
18000 / 18000
24000 / 24000
30000 / 30000
34000 / 34000
28000 / 28000
24000 / 24000
12000 / 12000
12000 / 12000
12000 / 12000
11110 / 11110
18000 / 18000
16670 / 16670
16670 / 16670
12000 / 12000
11000 / 11000
-/12000 / 12000

Unit-C

Unit-D

-/-/-/-/-/-/-/-/-/-/-/-/-/-/-/-/12000 / 12000
-/18000 / 18000
-/24000 / 24000
-/27780 / 27780
-/18000 / 18000
-/22220 / 22220
-/16670 / 16670
-/12000 / 12000 12000 / 12000
11000 / 11000 17000 / 17000
-/-/-/-/-

Circuit Unit
4720 / 4330
4730 / 4640
4580 / 4560
4700 / 4560
4720 / 4630
4790 / 4680
4790 / 4680
4720 / 4630
4580 / 4560
4680 / 4560
4720 / 4640
4790 / 4670
4720 / 4640
4790 / 4670
4790 / 4670
4720 / 4640
4790 / 4670
2550 / 2570
2450 / 2570

9.4 / 9.2
9.4 / 9.3
9.2 / 9.0
9.2 / 9.0
9.4 / 9.3
9.6 / 9.5
9.6 / 9.5
9.4 / 9.3
9.2 / 9.0
9.3 / 9.0
9.4 / 9.3
9.6 / 9.4
9.4 / 9.3
9.6 / 9.3
9.6 / 9.4
9.4 / 9.3
9.6 / 9.4
4.9 / 4.9
4.9 / 4.9

Notes:
1. Cooling Capacity is based on : indoor temp.27C(80.6F) DB, 19C(66.2F) WB; outdoor temp. 35C(95F) DB
2. The maximum capacity available for Circuit 1 is 54kBtu/h (15.8kW). The total capacity of indoor unit of "Circuit 2" is up to 24 kBtu/h (7.1kW).
3. The capacity is based on standard length of interconnecting refrigerant line. [Standard length : Direct Piping - 7.5m (25ft), Distributor Piping - Main 5m(16.4ft), Branch 7.5m (25ft)]
4. In case of the maximum capacity combinations of indoor unit the capacity might seem to be decreased due to the changes in discharge temperature of indoor units, while the total capacity(i.e. the total sum of
indoor units capacity) is to be slightly increased with increasing air flow rate of indoor units with respect to the overall system.

50

Capacity (Btu/h)

Current (A)

Total
48000 / 48000
48000 / 48000
36000 / 36000
42000 / 42000
48000 / 48000
50000 / 50000
50000 / 50000
48000 / 48000
36000 / 36000
42000 / 42000
48000 / 48000
50000 / 50000
48000 / 48000
50000 / 50000
50010 / 50010
48000 / 48000
50000 / 50000
24000 / 24000
24000 / 24000

Combination of Indoor units (k Btu/h)

1 unit

2 units
1
or
2
3 units

4 units

Unit-A Unit-B Unit-C Unit-D


48
12
18
18
18
18
24
24
12
12
12
12
12
12
18
12
12

36
18
24
30
36
30
24
12
12
12
12
18
18
18
12
12

12
18
24
30
18
24
18
12
12

12
18

Total

Unit-A

Unit-B

48
48
36
42
48
54
54
48
36
42
48
54
48
54
54
48
54

48000 / 48000
12000 / 12000
18000 / 18000
18000 / 18000
18000 / 18000
16000 / 16000
22000 / 22000
24000 / 24000
12000 / 12000
12000 / 12000
12000 / 12000
11110 / 11110
12000 / 12000
11110 / 11110
16670 / 16670
12000 / 12000
11000 / 11000

-/36000 / 36000
18000 / 18000
24000 / 24000
30000 / 30000
34000 / 34000
28000 / 28000
24000 / 24000
12000 / 12000
12000 / 12000
12000 / 12000
11110 / 11110
18000 / 18000
16670 / 16670
16670 / 16670
12000 / 12000
11000 / 11000

Unit-C

Unit-D

-/-/-/-/-/-/-/-/-/-/-/-/-/-/-/-/12000 / 12000
-/18000 / 18000
-/24000 / 24000
-/27780 / 27780
-/18000 / 18000
-/22220 / 22220
-/16670 / 16670
-/12000 / 12000 12000 / 12000
11000 / 11000 17000 / 17000

Input (W)

Current (A)

5300 / 4600
5300 / 4600
3800 / 3100
4500 / 3800
5300 / 4600
5400 / 4700
5400 / 4700
5300 / 4600
3800 / 3100
4500 / 3800
5300 / 4600
5400 / 4700
5300 / 4600
5400 / 4700
5400 / 4700
5300 / 4600
5400 / 4700

8.5 / 7.3
8.5 / 7.3
6.0 / 4.9
7.2 / 6.0
8.5 / 7.3
8.6 / 7.5
8.6 / 7.5
8.5 / 7.3
6.0 / 4.9
7.2 / 6.0
8.5 / 7.3
8.6 / 7.5
8.5 / 7.3
8.6 / 7.5
8.6 / 7.5
8.5 / 7.3
8.6 / 7.5

Total
48000 / 48000
48000 / 48000
36000 / 36000
42000 / 42000
48000 / 48000
50000 / 50000
50000 / 50000
48000 / 48000
36000 / 36000
42000 / 42000
48000 / 48000
50000 / 50000
48000 / 48000
50000 / 50000
50000 / 50000
48000 / 48000
50000 / 50000

Notes:
1. Cooling Capacity is based on : indoor temp.27C(80.6F) DB, 19C(66.2F) WB; outdoor temp. 35C(95F) DB
2. Heating Capacity is based on : indoor temp.20C(60F) DB; outdoor temp. 7C(44.6F) DB, 6C(42.8F) WB
3. The maximum capacity available is 54kBtu/h (15.8kW) per circuit.
4. The capacity is based on standard length of interconnecting refrigerant line. [Standard length : Direct Piping - 7.5m (25ft), Distributor Piping - Main 5m(16.4ft), Branch 7.5m (25ft)]
5. In case of the maximum capacity combinations of indoor unit the capacity might seem to be decreased due to the changes in discharge temperature of indoor units, while the total capacity(i.e. the total sum of
indoor units capacity) is to be slightly increased with increasing air flow rate of indoor units with respect to the overall system.

51

Combination Table

Combination Table

L8UC1508FA1

L8UC1508FA1

Cycle 2 : 60 kBtu/h

Cooling : There are two different cycles.


Cycle 1 : 90 kBtu/h
Cooling
Operation

Cooling

Combination of Indoor units (k Btu/h)

Operation

Combination of Indoor units (k Btu/h)


Capacity (Btu/h)

Capacity (Btu/h)
Input (W)
Circuit

Unit

2 units

3 units

4 units

Unit-A Unit-B Unit-C Unit-D


18
18
18
18
18
24
24
24
24
30
30
30
36
36
48
18
18
18
18
18
18
18
18
18
18
18
18
24
24
24
24
24
24
24
30
30
18
18
18
18
18
18
18
18
18
24

18
24
30
36
48
24
30
36
48
30
36
48
36
48
48
18
18
18
18
18
24
24
24
24
30
30
30
24
24
24
24
30
30
36
30
30
18
18
18
18
18
18
18
24
24
24

18
24
30
36
48
24
30
36
48
30
36
48
24
30
36
48
30
36
36
30
36
18
18
18
18
24
24
24
24
24
24

18
24
30
36
24
30
36
24
30
24

Total

Unit-A

Unit-B

36
42
48
54
66
48
54
60
72
60
66
78
72
84
96
54
60
66
72
84
66
72
78
90
78
84
96
72
78
84
96
84
90
96
90
96
72
78
84
90
84
90
96
90
96
96

19000
19000
19000
19000
15000
25000
25000
24000
25000
30000
27000
32000
38000
36000
45000
18000
18000
16000
19000
18000
16000
19000
19000
18000
19000
18000
16000
25000
25000
24000
22000
24000
24000
22000
30000
28000
19000
19000
18000
18000
18000
18000
16500
18000
16500
22500

19000
25000
31000
37000
45000
25000
31000
36000
49000
30000
33000
50000
38000
48000
45000
18000
18000
16000
19000
18000
22000
25000
25000
24000
31000
30000
28000
25000
25000
24000
22000
30000
30000
34000
30000
28000
19000
19000
18000
18000
18000
18000
16500
24000
22500
22500

Unit-C

18000
24000
28000
37000
48000
22000
31000
37000
48000
31000
36000
46000
25000
31000
36000
46000
30000
36000
34000
30000
34000
19000
19000
18000
18000
24000
24000
22500
24000
22500
22500

Unit-D

Total

19000
25000
30000
36000
24000
30000
34500
24000
28500
22500

38000
44000
50000
56000
60000
50000
56000
60000
74000
60000
60000
82000
76000
84000
90000
54000
60000
60000
75000
84000
60000
75000
81000
90000
81000
84000
90000
75000
81000
84000
90000
84000
90000
90000
90000
90000
76000
82000
84000
90000
84000
90000
90000
90000
90000
90000

Current (A)
Circuit

3380
5980
6220
6460
6940
6220
6465
6700
9000
6700
6940
9370
9000
9700
10500
6460
6700
6900
9000
9730
6940
9000
9370
10100
9370
9700
10400
9000
9300
9700
10400
9700
10100
10400
10100
10400
9000
9300
9700
10100
9700
10100
10400
10100
10400
10400

6.0
10.7
11.0
11.4
12.2
11.1
11.4
11.8
16.1
11.8
12.2
16.7
16.1
17.3
18.5
11.4
11.8
12.2
16.1
17.3
12.2
16.1
16.7
17.9
16.7
17.3
18.4
16.1
16.7
17.3
18.5
17.3
17.9
18.5
17.9
18.5
16.1
16.7
17.3
17.9
17.3
17.9
18.5
17.9
18.5
18.5

Unit

2 units

3 units

4 units

Unit-A Unit-B Unit-C Unit-D


18
18
18
18
18
24
24
24
24
30
30
18
18
18
18
18
18
24
18

18
24
30
36
48
24
30
36
48
30
36
18
18
18
18
24
24
24
18

18
24
30
36
24
30
24
18

18

Total

Unit-A

Unit-B

36
42
48
54
66
48
54
60
72
60
66
54
60
66
72
66
72
72
72

19000
19000
19000
19000
15000
25000
25000
24000
18000
30000
27000
18000
18000
16000
14000
16000
14000
20000
15000

19000
25000
31000
37000
45000
25000
31000
36000
42000
30000
33000
18000
18000
16000
14000
22000
20000
20000
15000

Unit-C

18000
24000
28000
32000
22000
26000
20000
15000

Unit-D

Total

15000

38000
44000
50000
56000
60000
50000
56000
60000
60000
60000
60000
54000
60000
60000
60000
60000
60000
60000
60000

Input (W)

Current (A)

3500
5980
6150
6350
6750
6150
6350
6560
6900
6600
6750
6350
6600
6750
6940
6750
6940
6940
6940

6.0
10.7
11.0
11.3
11.9
11.0
11.3
11.6
12.2
11.6
11.9
11.3
11.6
11.9
12.2
11.9
12.2
12.2
12.2

Notes:
1. Cooling Capacity is based on : indoor temp.27C(80.6F) DB, 19C(66.2F) WB; outdoor temp. 35C(95F) DB
2. The maximum capacity available for Circuit 1 is 96kBtu/h (28.1kW). The maximum capacity available for Circuit 2 is 72kBtu/h (21.1kW).
3. The capacity is based on standard length of interconnecting refrigerant line. [Standard length : Direct Piping - 7.5m (25ft), Distributor Piping - Main 5m(16.4ft), Branch 7.5m (25ft)]
4. In case of the maximum capacity combinations of indoor unit the capacity might seem to be decreased due to the changes in discharge temperature of indoor units, while the total capacity(i.e. the total sum of
indoor units capacity) is to be slightly increased with increasing air flow rate of indoor units with respect to the overall system.

Notes:
1. Cooling Capacity is based on : indoor temp.27C(80.6F) DB, 19C(66.2F) WB; outdoor temp. 35C(95F) DB
2. The maximum capacity available for Circuit 1 is 96kBtu/h (28.1kW). The maximum capacity available for Circuit 2 is 72kBtu/h (21.1kW).
3. The capacity is based on standard length of interconnecting refrigerant line. [Standard length : Direct Piping - 7.5m (25ft), Distributor Piping - Main 5m(16.4ft), Branch 7.5m (25ft)]
4. In case of the maximum capacity combinations of indoor unit the capacity might seem to be decreased due to the changes in discharge temperature of indoor units, while the total capacity(i.e. the total sum of
indoor units capacity) is to be slightly increased with increasing air flow rate of indoor units with respect to the overall system.

52

53

Wall Mounted Split Type

Optimized Cooling & Heating Air Flow


Cooling mode

Heating mode

The air vanes will be


adjusted according to
the mode of
operation. In heating
mode air will be
distributed at a lower
angle due to hot air
rising.

LG AIR CONDITIONERS 2009

JET Cool
With the Jet Cool function a
strong and cool air stream is
blown at high speed for 30
minutes, until the room
temperature reaches 18 C

Model
Power Supply

/ V / Hz

Cooling Capacity

kW
Btu/h

Even & Fast Air flow


LG Electronics air conditioner improves the difference between
high and low indoor temperatures . It allows you to reach your
desired temperatures even faster

Heating Capacity

kW

Healthy Dehumidification
Dehumidification mode reduces uncomfortable humidity from
the room without over cooling.

Btu/h
Current

Nominal running current

Fan

Motor Type

Row x column x FPI

Dimensions (WxHxD) Body

- Triple deodorizing filter is for absorbing VOC ingredient,


common odor
- Deodorizing efficiency
:10% up compared to norma deodorizatior filter

Weight
Sound Level (H/M/L)
Piping Connections

New chaos swing


The most comfortable airflow for the human body can
be found in nature. After countless analysis, LG has
applied the scientific chaos theory to its air conditioning
range, which effectively produces a
natural, fresh breeze.
The chaso theory is
a technology that
recreates the flow
of natural air
by controlling the angle
speed of the movement of
the air vane. Chaos swing technology also minimizes the
temperature difference between high and low places in the
room, creating a more comfortable and cooler environment.

54

5.28

7.03

12,000

18,000

24,000

3.52

5.28

7.03

12,000

18,000

24,000

0.28

0.35
Induction

Cross Flow Fan

Cross Flow Fan

Cross Flow Fan

40 x 1

62 x 1

70 x 1

cmm

10

13

14

cfm

353

459

494

F/Vac
mm
mm(inch)
kg(lbs)

Air Filter

Innovative quiet operation


To provide a comfortable, pleasant and well balanced
environment, LG air conditioners utilize a streamlined air fan
and a unique design which create
smooth air flow from the air conditioner
so that it operates under the lowest
noise level. The cross flow fan, stabilizer,
and rear guide which are the causes of
noise, have been redesigned by hydraulic
engineering. The number of revolutions
have been decreased or increased while
the amount of friction has been decreased
providing the most quiet air conditioners in the world.

Body

1 / 220~240 / 50

3.52

Induction

Drive
Coil

LMN(C)H246D5*0

1 / 220~240 / 50

0.22

Motor Output x Number of Unit

Capacitor

LMN(C)H186D5*0

1 / 220~240 / 50

Induction

Fan Type
Air Flow Rate (H)

Triple Deodorizing Filter

LMN(C)H126D4*0

dB(A)3

9.0 / 400

1.5 / 370

2.0 / 370

Direct Drive

Direct Drive

Direct Drive

2R x 15C x 20

2R x 15C x 20

2R x 15C x 20

840 x 270 x 153(33.1 x 10.6 x 6.0)

1,090 x 300 x 180(42.9 x 11.8 x 7.1)

1,090 x 300 x 180(42.9 x 11.8 x 7.1)

7 (15.4)

13 (28.7)

13 (28.7)

Long Life Filter

Long Life Filter

Long Life Filter


45 / 42 / 37

40 / 35 / 30

40 / 37 / 33

Liquid

mm(inch)

6.35 (1/4)

6.35 (1/4)

6.35 (1/4)

Gas

mm(inch)

12.7 (1/2)

12.7 (1/2)

15.88 (5/8)

mm

21.5 / 16.0

21.5 / 16.0

21.5 / 16.0

1.5

2.0

3.1

Drain(OD/ID)
Dehumidification Rate l/h

Fuse, Thermal Protector for Fan Motor

Safety devices

Thermistor

Temperature Sensor
Referigerant

R22

R22

R22

Referigerant Control

EEV

EEV

EEV

Connectable outdoor unit

Air Purifying System


The Nano PLASMA Air Purifying System, developed uniquely by
LG, not only removes microscopic contaminants and dust, but
also eliminates house mites, pollen and pet fur to prevent
allergic diseases like asthma. It also eliminates bad odors by
neutralizing odor particles. With a reusable filter that can
simply be cleaned with a vacuum cleaner, you can enjoy clean,
fresh air without the cost of regular filter changes.

Power and transmission interunit cable


(including earth)

No.* mm2

Multi M DX

Multi M DX

Multi M DX

4 x 0.75 (including earth)

4 x 0.75 (including earth)

4 x 0.75 (including earth)

Notes:1. Capacities are based on the following conditions:


Cooling: - Indoor Temperature 27C(80.6F) DB /19C(66.2F) WB
- Outdoor Temperature 35C(95F) DB /24C(75.2F) WB
- Interconnecting Piping Length 7.5m
- Level Difference of Zero.
Heating: - Indoor Temperature 20C(68F) DB / 15C(59F) WB
- Outdoor Temperature 7C(44.6F) DB / 6C(42.8F) WB
- Interconnecting Piping Length 7.5 m
- Level Difference of Zero.
2. Capacities are Net Capacities.
3. Due to our policy of innovation some specifications may be changed without notification.
4. *: See the page "Combination Table"

Odor Free! Dust Free! Allergy Free!

55

ARTCOOL Mirror

LG AIR CONDITIONERS 2009

ARTCOOL_Mirror Type
A little interior accent for the modern you.
The romantic pastel colors, subdued luster,modern texture and
the super slim design of LG ARTCOOL Mirror are the answers to
your unique mood and personality.

Model
Power Supply

/ V / Hz

Cooling Capacity

kW
Btu/h

Heating Capacity

kW
Btu/h

New concept interior airconditioner

Auto Clean

Current

Nominal running current

Fan

Motor Type

Golden ratio of bedroom! New shpe Interior!


Altemation from general air-conditioner
To grace image of room air-conditioner
Bring you to new interior bedroom

Capacitor
Row x column x FPI

Dimensions (WxHxD) Body

Conventional

Weight

Body

Piping Connections

5.28

7.03

12,000

18,000

24,000

3.52

5.28

7.03

12,000

18,000

24,000

0.28

0.35
Induction

Cross Flow Fan

Cross Flow Fan

Cross Flow Fan

40 x 1

62 x 1

70 x 1

cmm

10

14

17

cfm

353

494

600

F/Vac
mm
mm(inch)
kg(lbs)

Air Filter
Sound Level (H/M/L)

1/ 220~240 / 50

3.52

Induction

Drive
Coil

LMN(C)H246D8*0

1/ 220~240 / 50

0.22

Motor Output x Number of Unit


Air Flow Rate (H)

LMN(C)H186D8*0

1/ 220~240 / 50

Induction

Fan Type

A main cause of air conditioner odours is mould and bacteria


that breed in the heat exchanger. The Auto Clean function dries
the wet heat exchanger to help prevent mould and bacteria
from breeding thus significantly reducing the old rag smell and
saves you from frequent cleaning.

ART COOL - Innovation of new concept

LMN(C)H126DE*0

dB(A)3

9.0 / 400

2.0 / 370

2.0 / 370

Direct Drive

Direct Drive

Direct Drive

2R x 15C x 20

2R x 15C x 20

2R x 15C x 20

915 x 282 x165(36.0 x 11.1 x 6.5)

1,107 x 299 x 200(43.6 x 11.7 x 7.8)

1,107 x 299 x 200(43.6 x 11.7 x 7.8)

9.5 (20.9)

14.1 (31.1)

14.1 (31.1)

Long Life Filter

Long Life Filter

Long Life Filter


44 / 40 / 37

40 / 35 / 30

40 / 37 / 34

Liquid

mm(inch)

6.35 (1/4)

6.35 (1/4)

6.35 (1/4)

Gas

mm(inch)

12.7 (1/2)

12.7 (1/2)

15.88 (5/8)

mm

21.5 / 16.0

21.5 / 16.0

21.5 / 16.0

1.5

2.0

2.5

Drain(OD/ID)
Dehumidification Rate l/h

Fuse, Thermal Protector for Fan Motor

Safety devices

LG Auto Clean

Thermistor

Temperature Sensor
Referigerant

R22

R22

R22

Referigerant Control

EEV

EEV

EEV

Connectable outdoor unit


Power and transmission interunit cable
(including earth)

Various Color

1 STEP

*Mirror(R)

*Blue(B)

56

*Silver(V)

*Dark Wood(N)

Dries the
evaporator with
gentle low noise air
from the fan by
removing any
remaining moisture.
Pressing the Auto
Clean button will
activate the
automatic cleaning
function after the
cooling operation.

2 STEP
Removes moulds
through the Neo
Plasma system.

No.* mm2

Multi M DX

Multi M DX

Multi M DX

4 x 0.75 (including earth)

4 x 0.75 (including earth)

4 x 0.75 (including earth)

Notes:1. Capacities are based on the following conditions:


Cooling: - Indoor Temperature 27C(80.6F) DB /19C(66.2F) WB
- Outdoor Temperature 35C(95F) DB /24C(75.2F) WB
- Interconnecting Piping Length 7.5m
- Level Difference of Zero.
Heating: - Indoor Temperature 20C(68F) DB / 15C(59F) WB
- Outdoor Temperature 7C(44.6F) DB / 6C(42.8F) WB
- Interconnecting Piping Length 7.5 m
- Level Difference of Zero.
2. Capacities are Net Capacities.
3. Due to our policy of innovation some specifications may be changed without notification.
4. *: See the page "Combination Table"

Only the fan will


operate to dry the
inner part of the
air conditioner in
just 30 minutes.

57

Ceiling Cassette Type

LG AIR CONDITIONERS 2009

PLASMA Air Purifying System(Optional)


LG's unique PLASMA Air Purifying System not only reduces
microscopic contaminants and dust, but also filters house
mites, pollen and even pet fur to ease allergy and asthma
symptoms.
With a filter that can be used over and over again by simply
washing it, you can enjoy clean fresh air without having to worry
about changing the filter every couple of years or so resulting in
cost savings.

Drain leakage
check

Hanger adjust

Hanger adjust

4 Vane Independent Operation: PARCUSA0


Vane angle control satisfies both users who like direct wind
or indirect wind.And also it prevents cold air draft.
- This function can be controled with new wired remote
controller

Model
Decorative Panel Model
Power Supply

/V/Hz

Cooling Capacity

kW
Btu/h

Heating Capacity

kW
Nominal running current

Fan

Motor Type

1) Basic Operation
- Linking several units, one Group Control Unit can manage a
number of indoor units.
2) Control Features
- Through a data cable connected to each indoor unit, a group
of units can be managed from the group controller.
- The Group Control function is enabled by cutting an optional
jump wire in the wired remote control, which prevents data
collision.
- One Group Control Unit can control up to 16 indoor units.
1

........

16

Capacitor
Coil

Row x column x FPI

Dimensions (WxHxD) Body


Decorative Panel

With reverse cycle models,the air conditioner will switch


automatically from cooling to heating modes depending on
the set temperature.
Initial Setting Temp :18 C: (Memory the final setting temp)
Control of setting temp.
Wired Remoted Controller:18~30 C
Reset Button in indoor unit: finally memorized temp.
Wireless Remoted Controller: 23~27

Weight

1/ 220 ~240/ 50

1/ 220~240 / 50

1/ 220 ~240/ 50

1/ 220~240 / 50

1/ 220~240 / 50

3.52

5.28

7.03

8.79

10.55

14.07

12,000

18,000

24,000

30,000

36,000

48,000

8.79

10.55

14.07

30,000

36,000

48,000

12.6 / 12.7

16.0 / 16.4

0.6

0.6

0.6

0.7

BLDC

BLDC

BLDC

BLDC

BLDC

BLDC

Turbo fan

Turbo Fan

Turbo fan

Turbo Fan

Turbo Fan

Turbo Fan

60 x 1

60 x 1

60 x 1

124 x 1

124 x 1

124 x 1

cmm

9.5 / 8.0 / 7.0

13.0 / 12.0 / 11.0

17.0 / 15.0 / 13.0

22.0 / 19.0 / 17.0

25.0 / 22.0 / 19.0

33.0 / 29.0 / 25.0

cfm

336 / 283 / 247

777 / 671 / 600

600 /530 / 459

777 / 671 / 600

883 / 777 / 671

1 165 / 1 024 / 883

Direct drive

Direct drive

Direct drive

Direct drive

Direct drive

Direct drive

2 x 8 x 18

2 x 10 x 18

2 x 8 x 19

2 x 10 x 19

2 x 10 x 19

2 x 12 x 19

F/Vac
mm
mm(inch)
mm

570x214x570(22.4x8.4x22.4) 570x256x570(22.4x10.0x22.4) 840x204x840(33.1x8.0x33.1) 840x246x840(33.1x9.7x33.1) 840x246x840(33.1x9.7x33.1) 840x288x840(33.1x11.3x33.1)


700 x 30 x 700

700 x 30 x 700

950 x 37 x 950

950 x 37 x 950

950 x 37 x 950

950 x 37 x 950

kg(lbs)

14 (30.9)

15 (33.1)

22.0 (48.5)

23.5 (51.8)

23.5 (51.8)

25.6 (56.4)

Decorative Panel

kg(lbs)

3 (6.6)

3 (6.6)

5.6 (12.3)

5.6 (12.3)

5.6 (12.3)

5.6 (12.3)

Long life filter

Long life filter

Long Life Filter

Long Life Filter

Long Life Filter

Long Life Filter


50 / 47 / 43

dB(A)3

38 / 35 / 32

41 / 39 / 36

39 / 37 / 34

40 / 36 / 33

44 / 41 / 39

Liquid

mm(inch)

6.35 (1/4)

6.35 (1/4)

6.35 (1/4)

6.35 (1/4)

6.35 (1/4)

9.52 (3/8)

Gas

mm(inch)

12.7 (1/2)

12.7 (1/2)

15.88 (5/8)

15.88 (5/8)

15.88 (5/8)

19.05 (3/4)

mm

32 / 25

32 / 25

32 / 25

32 / 25

32 / 25

32 / 25

l/h

1.2

2.4

2.0

2.5

4.3

6.7

OD/ID

Dehumidification Rate

Fuse, Thermal Protector for Fan Motor

Safety devices

Thermistor

Temperature Sensor
Referigerant Control
Connectable outdoor unit
Power and transmission interunit cable
(including earth)

No.* mm2

R22

R22

R22

R22

R22

R22

EEV (in DB Unit)

EEV (in DB Unit)

EEV (in DB Unit)

EEV (in DB Unit)

EEV (in DB Unit)

EEV (in DB Unit)

Multi M DX

Multi M DX

Multi M DX

Multi M DX

Multi M DX

Multi M DX

4 x 0.75
(including earth)

4 x 0.75
(including earth)

4 x 0.75 (including

4 x 0.75
(including earth)

4 x 0.75
(including earth)

4 x 0.75
(including earth)

earth)

Notes:1. Capacities are based on the following conditions:


Cooling: - Indoor Temperature 27C(80.6F) DB /19C(66.2F) WB
- Outdoor Temperature 35C(95F) DB /24C(75.2F) WB
- Interconnecting Piping Length 7.5m
- Level Difference of Zero.
Heating: - Indoor Temperature 20C(68F) DB / 15C(59F) WB
- Outdoor Temperature 7C(44.6F) DB / 6C(42.8F) WB
- Interconnecting Piping Length 7.5 m
- Level Difference of Zero.
2. Capacities are Net Capacities.
3. Due to our policy of innovation some specifications may be changed without notification.
4. *: See the page "Combination Table"

Elevation Grille (Accessory :PTEGMO)


Easy filter cleaning with elevation grille
- Installed inside main body - Auto horizontal level
- 4 points support
- Memory for user s level
- Max.4.5m length

PT-UMC

1/ 220~240 / 50

7.03

Referigerant

........

LMN(C)H48GTMA0

Body

Sound Level (H/M/L)

Drain

PT-UMC

24,000

Air Filter
Piping Connections

LMN(C)H36GTNA0

PT-UMC

5.28

Drive

Auto Changeover

LMN(C)H30GTNA0

PT-UMC

18,000

Motor Output x Number of Unit


Air Flow Rate (H/M/L)

LMN(C)H24GTPA0

PT-UQC

3.52

Fan Type

Group Control

LMN(C)H18GTQA0

PT-UQC

12,000

Btu/h
Current

LMN(C)H12GTRA0

High Ceiling corresponding Operation


According to the ceiling height, the speed of the internal fan can
be adjusted with a sliding switch on the back of the wired
remote control unit.

4way
4.5m

Conventional
3.5m

4-Point Support Structure Auto Horizontal Control

Memory for users level

Auto bottom detection

Air Velocity Distribution

58

59

Ceiling Concealed Duct


(high static pressure)

LG AIR CONDITIONERS 2009

*E.S.P: External Static Pressure


The air volume and sound level is kept constant as designed
regardless of changes in E.S.P.(External Static Pressure)

Compact & Light Design and Easy Installation


Flexible duct is easy to install Regardess of room size or heater
position it can be installed even in a limited space and saves
construction cost as the unit has slim thickness

E.S.P. technology
- Optimizes Duct Installation
- Keeps Capacity & Sound Levels within desired ranges
- Reduces the number of models

Ceiling
Canvas Duct
Intake
Duct

Indoor Unit

Discharge
Flexible Duct

LMN(C)H186BHA0 LMN(C)H246BHA0 LMN(C)H306BGA0 LMN(C)H366BGA0 LMN(C)H486BRA0 LMN(C)H126BTG0 LMN(C)H186BTG0 LMN(C)H246BYG0

Model

Phase control motor technology reduces installation costs. The


desired air flow is obtained by adjusting the phase motor during
installation of the product, giving you more flexibility when
setting up your duct system. The E.S.P can be adjusted linearly
from 0 to 10mmAq.

Power Supply
Ceiling Board
Air Intake Port

Inspection Port

Air Discharging Port

/ V / Hz

Cooling Capacity

kW
Btu/h

Heating Capacity

kW
Btu/h

(Linear E.S.P. control)


LGs high technology provides easy and low cost design of
duct work. E.S.P. settings through LCD wired remote controller
gives required combination of E.S.P. and airflow rate.
- High head drain pump(700mm, accessory) In some places
natural drainage is not possible. For such conditions LGs
high head drain pump is very useful to removes condensed
water from the unit.

Current

Nominal running current

Fan

Motor Type

Dimensions (WxHxD) Body

1/ 220~240 / 50

1/ 220~240/ 50

1/ 220~240/ 50

10.55

14.07

3.52

5.28

7.03

18,000

24,000

30,000

36,000

48,000

12,000

18,000

24,000

5.28

7.03

8.79

10.55

14.07

3.52

5.28

7.03

18,000

24,000

30,000

36,000

48,000

12,000

18,000

24,000

1.42

1.42

3.65

0.31

0.58

0.58

Induction

Induction

Induction

Induction

Induction

Induction

Sirocco Fan

Sirocco Fan

Sirocco Fan

Sirocco Fan

Sirocco Fan

Sirocco Fan

Sirocco Fan

Sirocco Fan

118 x 1

118 x 1

272 x 1

272 x 1

431 x 1

35 x 1

47 x 1

100 x 1

cmm

16.5/14.5/13.0

18.0/16.5/14.0

26.5/23.0/20.0

32.0/29.0/26.5

40.0/35.0/30.0

10.0/9.0/8.0

13.5/12.0/10.0

17.2/16.0/14.0

cfm

583/512/459

636/583/494

936/812/706

352/317/282

477/424/353

618/565/494

10

10

15

6 / 370

6 / 370

6 / 370

6 / 370

15 / 450

2.5/400

2.5/370

3.5/370

F/Vac
mm
mm(inch)

1 130/1 024/936 1,413/1,236/1,059

Direct Drive

Direct Drive

Direct Drive

Direct Drive

Direct Drive

Direct Drive

Direct Drive

Direct Drive

3R x 10C x 21

3R x 10C x 21

3R x 12C x 21

3R x 12C x 21

3R x 13C x 19

3R x 12C x 18

2R x 12C x 18

3R x 12C x 19

880x260x450

880x260x450

1,180x298x450

1,180x298x450

1,230x380x590

650x230x535

(34.6x10.2x17.7) (34.6x10.2x17.7) (46.5x11.7x17.7) (46.5x11.7x17.7) (48.4x15.0x23.2) (25.6x9.0x21.1)

Piping Connections

Air flow rate


at 2 mmAq

It controls temperature of each zone.

By sensing the temperature of each zone, opening or closing of


the damper is controlled automatically as per the airflow
requirement

Air flow rate


at 2 mmAq

10

12

Static pressure(mmAq)

35

70

105

140

175

215

245

Controller

ROOM1
temperature
sensor

ROOM2
temperature
sensor

Group Control
Auto Damper
Auto Damper

1) Basic Operation
- Linking several units, one Group Control Unit can manage a
number of indoor units.
2) Control Features
- Through a data cable connected to each indoor unit, a group
of units can be managed from the group controller.
- The Group Control function is enabled by cutting an optional
jump wire in the wired remote control, which prevents data
collision.
- One Group Control Unit can control up to 16 indoor units.

........

Zone Control
sub PCB

ROOM3
temperature
sensor

kg(lbs)

Auto Damper
Auto Damper

ROOM4
temperature
sensor

35(77.2)

35(77.2)

38(83.8)

38(83.8)

60(132.3)

22 (48.5)

1,000x230x535

1,200x230x535

(39.4x9.0x21.1)

(47.2x9.0x21.1)

29 (63.9)

36 (79.3)

Long Life Filter Long Life Filter Long Life Filter Long Life Filter Long Life Filter Long Life Filter Long Life Filter Long Life Filter

Sound Level (H/M/L)

M
L

Body

Air Filter

Zone Control (Accessory)

H
L

Air volume

Air volume

Weight

1/ 220~240/ 50

0.92

Drive
Row x column x FPI

1/ 220~240 / 50

8.79

Induction

External Static Pressure mmAq

Coil

1/ 220~240 / 50

7.03

0.92

Motor Output x Number of Unit

Capacitor

1/ 220~240 / 50

5.28

Induction

Fan Type
Air Flow Rate
(H/M/L)

1/ 220~240 / 50

dB(A)3

36 / 34 / 32

38 / 36 / 34

40 / 38 / 35

42 / 39 / 36

44 / 42 /30

37 / 34 / 31

38 / 36 / 34

Liquid

mm(inch)

6.35 (1/4)

6.35 (1/4)

6.35 (1/4)

6.35 (1/4)

9.52(3/8)

6.35 (1/4)

6.35 (1/4)

6.35 (1/4)

Gas

mm(inch)

12.7(1/2)

15.88(5/8)

15.88(5/8)

15.88(5/8)

19.05(3/4)

12.7(1/2)

12.7(1/2)

15.88 (5/8)

mm

25.4 / 22.6

25.4 / 22.6

25.4 / 22.6

25.4 / 22.6

25.4 / 22.6

25.4 / 22.6

25.4 / 22.6

25.4 / 22.6

l/h

2.0

2.5

3.0

3.5

6.0

1.2

2.0

2.6

Drain(OD/ID)
Dehumidification Rate

42 / 40 / 38

Fuse, Thermal Protector for Fan Motor

Safety devices

Thermistor

Temperature Sensor
Referigerant

R22

R22

R22

R22

R22

R22

R22

R22

Referigerant Control

EEV

EEV

EEV

EEV

EEV

EEV

EEV

EEV

Multi M DX

Multi M DX

Multi M DX

Multi M DX

Multi M DX

Multi M DX

Multi M DX

Multi M DX

Connectable outdoor unit


Power and transmission interunit cable
(including earth)

No.* mm2

4 x 0.75
4 x 0.75
4 x 0.75
4 x 0.75
4 x 0.75
4 x 0.75
4 x 0.75
4 x 0.75
(including earth) (including earth) (including earth) (including earth) (including earth) (including earth) (including earth) (including earth)

Notes:1. Capacities are based on the following conditions:


Cooling: - Indoor Temperature 27C(80.6F) DB /19C(66.2F) WB
- Outdoor Temperature 35C(95F) DB /24C(75.2F) WB
- Interconnecting Piping Length 7.5m
- Level Difference of Zero.
Heating: - Indoor Temperature 20C(68F) DB / 15C(59F) WB
- Outdoor Temperature 7C(44.6F) DB / 6C(42.8F) WB
- Interconnecting Piping Length 7.5 m
- Level Difference of Zero.
2. Capacities are Net Capacities.
3. Due to our policy of innovation some specifications may be changed without notification.
4. *: See the page "Combination Table"

Plasma Air Purifying System (Accessory)


The PLASMA air purifying function not only removes
microscopic contaminants and dust, but also removes house
mites pollen and pet fur and hence its helps to prevern allergic
diseases like asthma.

16

........

60

61

LG AIR CONDITIONERS ACCESSORY

Simple Central Controller

LG AIR CONDITIONERS ACCESSORY

AC Smart

Features

Features

Simple and easy central control for 16 indoor units is made by this controller, a distinctive product.

For the mid sized buildings up to 64 or 128 indoor units can be controlled and monitored by touch scrren
central controller. Its possible to control and monitor the air conditioning system through web access,
anywhere with computer.

PQCSB101S0
Max. no. of indoor units

16 indoor units

Individual control

On_Off control

Lock function

Total / Individual

Mode change

Cooling / Heating

Malfunction indicator
Dimension(mm)
Power(V)

LED lamp
120x120x20
DC 10V

PQCSW320A0E

PQCSB101S0

PQCSE440U0
LG AIR CONDITIONERS ACCESSORY

Function Cotroller & Scheduler

*128 Indoor unit Expansion Kit: PQCSE440U0


*DO Kit: PQNFP00T0

Features
It is possible to control, monitor and schedule the operation of indoor Units by using these controller in
company in company with a asimple central controller

RS485
0.75mm2 X 2C (shield)

PQCSB101S0
PQCSC101S0
PQCSW502A2
Max.no. of indoor units
Individual control
Lock function
Mode change
Malfunction indicator

PQCSB101S0
PQCSD130S0

Schedule
Dimension(mm)
Power(V)

16 indoor units
On_Off/Fan speed/Mode/Temp.
Total/Individual
Cooling/Heating/Fan
Error display on LCD
(120x120x20+(70x120x14)
DC 10V

PQCSW502A2

16 indoor units
On_Off/Fan speed/Mode/Temp.
Total/Individual
Cooling/Heating/Fan
Error display on LCD
Weekly
(120x120x20+(120x133x20)
DC 10V

AC Smart
PQCSW320A0E

PI485

AC220V
DC Comm, Line

PMNFP14A0 (Max. 16 Indoors)


PMNFP14A1 (Max. 48 Indoors)

MULTI

PI485
PHNFP14A0 (Ceiling & Floor, Duct)
PSNFP14A0 (CST, RAC)

Single constant

* 1 Function controller combined with max. 8 simple central controllers.

PI485
PMNFP14A0

62

63

LG AIR CONDITIONERS ACCESSORY

ACP

LG AIR CONDITIONERS ACCESSORY

ACP & Manager

Features

Features

Through embedded web control function in ACP one can control and monitor various functions of
air-conditioner such as temperature setting, schedule, peak power control, etc.

AC Manager is suitable for large site because AC Manager is the S/W that can control Max. 16 ACP
(Max.4,096 indoor units).

PQCPA11A0E[Without IO]
PQCPB11A0E[With IO]

Application

AC Manager
PQCSS520A0E
MULTI

HUB

PHNFP14A0

Single constant

Internet

Max. 4,096 Indoor

PMNFP14A0 (Ceiling & Floor, Duct )/ PSNFP14A0(CST,RAC)

Korean reference Site

64

ACP

AC Manager

65

LG AIR CONDITIONERS ACCESSORY

BNU-LW Gateway (Building Network Unit-LonWorks)

LG AIR CONDITIONERS ACCESSORY

BNU-BAC (Building Network Unit-BACnet)

Features

Features

Connection to
using LONTALK protocol and LG Air-conditioner protocol
Process ability
- 64 units( including indoors and ventilators)
- Valid address for each unit : 0x00 ~ 0x3F
Self installation verification function using internet (Web server included)
- Setting gateway
- Diagnosis of communication status on
LG Air-conditioner network
Connection to remote total management system (LG system)

Through embedded web control function in BACnet one can access the airconditioner and
externaldevices through internet.
It can control 256 indoor units. ( A/C or Ventilator )
External devices such as fire alarm, motion detector can be connected to gateway and their function can
be interlinked with airconditioner operation.

PQNFB17B0
Controlling

PQNFB16A1

On/Off command
Operation mode setting
Fan Speed setting
Lock setting
Air flow setting
Set temp. setting
User mode setting (for only ventilator)

Monitoring Items

Controlling

On/Off status report


Operation mode status report
Fan Speed status report
Lock status report
Air flow status report
Set temp. status report
Current Space temp. status report
Error status report
User mode status report
(for only ventilator)

Combination

On/Off command
Operation mode setting
Fan Speed setting
Lock setting
Air flow setting
Set temp. setting
User mode setting (for only ventilator)

Monitoring Items

On/Off status report


Operation mode status report
Fan Speed status report
Lock status report
Air flow status report
Set temp. status report
Current Space temp. status report
Error status report
User mode status report
(for only ventilator)

Combination

BACnet
Network

Network
BMS system

BMS system

BACnet comm. line

LON comm. line

Lighting control

Remote checking

Indoor unit : Max. 64 units (Air-conditioner & ventilation)


Indoor address : 00 ~ 3F

Utility control

Lighting control

Indoor unit : Max. 64 units (Air-conditioner & ventilation)


Indoor address : 00 ~ 3F

Other LON devices

RS485

BNU-LW

PI485
MULTI

BACnet

MULTI

PQNFB17B0
PHNFP14A0

or

PI485

PI485

PHNFP14A0

66

Other LON devices

PI485

PHNFP14A0

Simple central
controller

Utility control

RS485

PQNFB16A1

or

Remote checking

PHNFP14A0

AC Smart
Outdoor unit

Indoor unit

Simple central
controller

AC Smart
Outdoor unit

Indoor unit

67

LG AIR CONDITIONERS ACCESSORY

PDI

LG AIR CONDITIONERS ACCESSORY

Dry Contact

Features

Features

Accumulated total power consumption indicated


Accumulated/Current power consumption of each indoor unit indicated.
Accumulated power consumption by month indicated
Max. connectable no. of indoor units : 48 indoor units
1 PDI per 1 outdoor unit
Power failure-proof function : Data back up on EEPROM even if power turns off
Connectable to PC based central controller
Simple connection with the remote metering system (RS485 approach)
Power distribution indication formula

It is connected between indoor units and external device,


so it can be used for various purpose

PQDSA(B)
Power input
Voltage / Non voltage input

PQNUD1S00

Power used per room =

Total power consumed


for an external unit

On_Off control

weight by room
total weight

* Weight by room : Weight calculated based on the temperature set by room, mode
and operating time.

LG AIR CONDITIONERS ACCESSORY

Lock / Unlock
Fan speed setting
Thermo off

PQDSA(B)
PQDSB1
PQDSBC

PQDSB1

PQDSBC

1 Control point
1 Control point
AC 220V from outside AC 220V from outside
power source
power source

Contact point

Energy saving
Temperature setting
Error monitoring
Operation monitoring







2 Control point
DC 5V&12V from
indoor unit PCB











Refer to each model PDB for applicable models.


With case model : PQDSB, PQDSB1, PQDSBC
Without case model : PQDSA

PI 485
Dry contact
(Contact point linked
with Outer part)

Features
PI 485 convert the protocol of air conditioner to the RS 485 protocol for central controller.

Key
Switch

Lighting
Sensor

Fire
Alarm

Timer

Motion
Detect
Sensor

Door
Chek
Sensor

System Structure

Model name : PMNFP14A0


Power : Single phase AC 220V 50/60Hz

Parts Description

Max. no of the indoor units that can be connected : 16 units


Model applied : MULTI, Single A
CN-POWER : AC 220V connector
CN-CC : MAINPCB connector
CN-DRY(L) : DRY CONTROLLER connector
CN-DRY(SIG) : DRY CONTROLLER connector
CN-DRY(ERROR CHECK) : ERROR check display connector
CN-DRY(OPER STATE) : Operation display connector

PMNFP14A0
PHNFP14A0 / PSNFP14A0
Model name : PHNFP14A0
Power : Connected with the indoor units
Max. no of the indoor units that can beconnected : 1 units
Model applied : Single (Duct, CVT) , Eco V
<PQDSA(B) / PQDSB1>

Model name : PSNFP14A0


Power : Connected with the indoor units
Max. no of the indoor units that can be connected : 1 units
Model applied : Single (RAC, PAC, CST)
* Tropical Multi V dont need PI 485

68

<PQDSBC>

CN_INDOOR2 : Connector for Main <-> Dry Contact


CN_INDOOR1 : PI 485 Connector
CHANGE_OVER_SW : Switch for selecting junction signal Voltage(5V~12V) or Non Voltage
CN_CONTROL : Connector for input junction signal
CONTROL_MODE_SW : Switch for selecting control mode
SETTING_SW : Switch for selecting Dry Contact setting function
TEMP_SETTING : Switch for setting desired temperature
CN_OUT(O1,O2) : Terminal Block for displaying main operation
CN_OUT(E3,E4) : Terminal Block for displaying main error
DISPLAY_LED : LED for displaying status of Dry Contact
RESET_SW : Reset Switch

69

LG AIR CONDITIONERS ACCESSORY

LG AIR CONDITIONERS ACCESSORY

Remote Temperature Sensor

Features
It can help to detect the exact room temperature at the optimal position.
Model applied to Cassette, Duct type.
Part supplied
- Remote temperature sensor
- Cable (15m)
- Manual

Wiring Diagram
PQRSTA0
1. Wire to the control box in the indoor unit by removing the existing thermistor and connect the
extension cable its place.
2. Cut the extension cable to the appropriate length and connect the screw terminal of the remote
sensor.
3. In the case of wired remote controller installed, set the temperaturesensing slide s/w at MAIN mode.

Extension cable

Connector

Screw terminal
connection

Indoor unit

Remote Temperature
Sensor

70