Download as pdf
Download as pdf
You are on page 1of 1
Jamb Bars & lapping ‘LU bars \ Z Concrete in open perpend poured against closed perpend Closed perpend unit 20 dia capped dowel 600 long f Joint: Polystyrene is compressible | S55! \ Ensure finish has min 20 gap 200™m@x PLAN A-A _- 20 dia dowel is a plain bar, greased, ends deburred, capped with uPVC. conduit sealed one end, 50 mm A clear at bar end for compression \ === ___ Bearing, steel trowel finish top of jamb then 2 sheets, greased gi i Actltiong| 1Y12barineach | B ars. B core adjacent to a joint. No starters or top 'L' bars req'd Jamo 1 \ bars as req'd for | specie — wind load, ___-_—"] , 1yi2 placed one (Ne seer core back tarred) from jamb Y Joint: Polystyrene is compressible “| Lap with \ Ensure finish has min 20 gap Starters and ‘Lars at top ‘pe DETAIL 'B' from DWG 04-02) PLAN B-B DETAIL ‘A’ from DWG 04-02 Suitable for Use in Mine Subsidence Areas and Problem Soils, where approved by the Building Authority. ARTICULATED CONSTRUCTION - DETAILS ZEGO "MAGU" ICF's IN DOMESTIC ZEGO |_STRUCTURES 1:10 ~____ | ZEGO Pty Limited Dwg No 04-03 nsuisted Concrete Forms (CF 8}! RS HEMPHILL PTY LTD CONSULTING ENGINEERS ABN 99705 451 917 ponent DATE _ April 02 PROJECT No 02 ISSUE No_A