case(i) ALL GATES OPEN

Pier length=
Max direct load from pier=
Max. Moment from Pier =
Max load from pier per mt. =
Max Moment from pier per mt. =
Wt. of water above raft =
Wt of water per mt. =
Self wt. of Raft =
bouyant wt. of raft =
Total wt. on soil underneath the raft =
134.504

134.504

33.571
7.75

33.571
7.75

1.75

47.469
605.270
33.571

7
13.5

488.250
453.209
33.571

7
22.5

18

976.500
3026.350
33.571

7
31.5

27

1464.750
4236.891
33.571

3.5

34.25

929.031
1393.200
13755.205
16.524
1.476
x( 1

7.75
2

7
36

18
Total Moment =
x=
e=
Stresses =
832.418
36
Max. Stress = 28.809 t/m2
Min. Stress = 17.436 t/m2
Net Stresses
Max. Stress = 26.659 t/m2
Min. Stress = 15.286 t/m2

134.504

3.5
4.5

2.15

1.70 M
4
7.00 M

33.571
7.75

3.5

+ 148.000 M
+ 140.987 M
+ 133.237 M
+ 134.337 M
+ 134.237 M
+ 133.087 M

134.504

33.571
7.75

CG of load system
7.75
134.504
33.571
+
7.75
33.571
33.571
+
7.75
134.504
33.571
+
7.75
134.504
33.571
+
7.75
+
36

FRL =
FSL=
Cistern level =
CBL u/s
CBL d/s
Raft top level =
Raft thickness=
No. Of piers =
Width of vent=

10.30 M
1385.40 T
345.782 T-m
134.50 T
33.571 T-m/m
217.00 T
7.750 T/m
4.250 T/m
2.150 T/m
832.418 T

6x

1.476 )
36