Download as ppt, pdf, or txt
Download as ppt, pdf, or txt
You are on page 1of 15

Bharat Heavy Electricals Limited, Tiruchy

BHEL Standard 500 MW Boilers

CEA Workshop, May - 2005

Bharat Heavy Electricals Limited, Tiruchy

Boiler Parameters
Main Steam

BMCR

500 MW

CL 250 MW

Steam flow at SHO

t/hr

1625

1495.2

772.7

Pressure at SHO

Kg/cm2(g)

178

176.7

171.1

Temp at SHO

540

540

540

Steam flow at RHO

t/hr

1392.4

1334.9

670.2

Pressure at RHI

Kg/cm2(g)

45.03

43.21

21.39

Pressure at RHO

Kg/cm2(g)

42.39

40.69

20.13

Temperature at RHI

337

336.7

311.4

Temp at RHO

540

540

540

Feed Water Temp

254.6

253.4

219.3

Reheat Steam

CEA Workshop, May - 2005

Bharat Heavy Electricals Limited, Tiruchy

Proximate Analysis of Unwashed Coal


Group I

Group II

Group III

Design
Coal

Range

Design
Coal

Range

Design
Coal

Range

Fixed Carbon %

34.5

32 37

28

24 32

22

20 24

Volatile Matter %

23

22 24

23

22 24

20.5

19 22

Total Moisture %

10

9 11

12.5

11 14

13.5

12 15

Ash %

32.5

32 33

36.5

33 40

44

42 46

Total %

100

100

HHV K.cal/kg

4250

4000 4500

3700

3400 4000

3100

2800 3400

50

45 - 55

50

45 - 55

50

45 - 55

HGI

CEA Workshop, May - 2005

100

Bharat Heavy Electricals Limited, Tiruchy

Proximate Analysis of Unwashed Coal


Group I

Group II

Group III

Best
Coal

Design
Coal

Worst
Coal

Best
Coal

Design
Coal

Worst
Coal

Best
Coal

Fixed
Carbon %

37

34.5

32

32

28

24

24

22

20

Volatile
Matter %

22

23

24

24

23

22

22

20.5

19

Total
Moisture %

10

11

11

12.5

14

12

13.5

15

Ash %

32

32.5

33

33

36.5

40

42

44

46

Total %

100

100

100

100

100

100

100

100

100

HHV
K.cal/kg

4500

4250

4000

4000

3700

3400

3400

3100

2800

55

50

45

55

50

45

55

50

45

HGI

CEA Workshop, May - 2005

Design Worst
Coal
Coal

Bharat Heavy Electricals Limited, Tiruchy

Expected Proximate Analysis (Range) of Washed Coal


Group I
Washed

Group II

Unwashed Washed

Group III

Unwashed

Washed

Unwashed

Fixed Carbon

35 - 40

32 - 37

33 38

24 - 32

30 35

20 - 24

Volatile Matter

25 - 28

22 - 24

23 26

22 - 24

21 23

19 - 22

Total Moisture

11 - 13

9 - 11

13 16

11 - 14

14 17

12 - 15

Ash

23 - 25

32 - 33

25 28

33 - 40

28 30

42 - 46

Total

100

100

100

100

100

100

HHV K.cal/kg

4500 4800

4000 4500

4000
4500

3400 - 4000

3500
4000

2800 - 3400

HGI

55 - 65

45 - 55

55 - 65

45 - 55

55 - 65

45 - 55

CEA Workshop, May - 2005

Bharat Heavy Electricals Limited, Tiruchy

Salient Features
Two-pass design
Controlled circulation
Pressure part materials selection as per code.
Radiant reheat
Balanced draft
Side mill layout
cold PA system

CEA Workshop, May - 2005

Bharat Heavy Electricals Limited, Tiruchy

Salient Features contd.


Axial reaction FD fans
Axial reaction PA fans
Radial ID fans with VFD
Regenerative Tri-sector air preheaters
Vertical spindle bowl mills
Gravimetric feeders
ESP to suit outlet dust emission
Micro-processor based BMS, SADC and SB
controls.
CEA Workshop, May - 2005

Bharat Heavy Electricals Limited, Tiruchy

BOILER ARRANGEMENT

CEA Workshop, May - 2005

Bharat Heavy Electricals Limited, Tiruchy

Design Details Unwashed Coal


Group I

Group II

Group III

Furnace Depth - mm

~ 1.05 D

1.14 D

Furnace With - mm

Furnace height - mm

~ 1.04 H

~ 1.08 H

Furnace Plan Area - m2

PA

~ 1.05 PA

~ 1.14 PA

Furnace Volume - m3

1.09 V

1.24 V

4.28

4.15

3.86

1.77

1.74

1.68

82.2

75.9

67.4

Furnace Heat Loadings- BMCR DC


Plan Area
EPRS

M K.cal/h-m2
105 K.cal/h-m2

Volumetric 103 K.cal/h-m3

CEA Workshop, May - 2005

Bharat Heavy Electricals Limited, Tiruchy

Design Details Unwashed Coal


Heat Input per burner M K.cal / hr

Group I

Group II

Group III

74.8

60.3

50.7

Max Gas Velocity in horz pass /


second pass m/s

12 / 10

Cold air / hot air duct velocity m/s

12.7 / 16

Gas duct velocity m/s

16

Excess Air at Eco. out let %

20

Boiler Exit Gas Temp oC

125 at TMCR with Design coal (DC)

Boiler Efficiency at TMCR DC %

Base

- 0.7

- 1.4

Coal Fired BMCR DC - T/hr

285

330

400

Coal Fired BMCR WC - T/hr

305

365

450

CEA Workshop, May - 2005

Bharat Heavy Electricals Limited, Tiruchy

Major Boiler Auxiliaries Unwashed Coal


Bowl Mills

Group I

Group II

Group III

6 Nos
BHEL 280
(XRP 1063)

7 Nos
BHEL 280
(XRP 1063)

8 Nos
BHEL 280
(XRP 1103)

No. of Spare mills

1 mill spare with Worst coal at BMCR

Regenerative AH

2 Nos Tri Sector - 31.5 VI 80 (T)

FD Fans - 2 Nos Axial


PA Fans - 2 Nos Axial
ID Fans
ESP Out let Dust
concentration

CEA Workshop, May - 2005

AP1-26/16
AP2-20/12

AP2-21/12

2 Nos Radial with VFD - NDZV 47


100 mg/Nm3 with n -1 fields in service

Bharat Heavy Electricals Limited, Tiruchy

FD Fan Performance (per fan)


Group I

Group II

Group III

BMCR
DC

Fan
DP

BMCR
DC

Fan
DP

BMCR
DC

Fan
DP

Volume

m3/s

155.3

215

145.9

210

126.8

200

Head

mmwc

255

385

238

395

208

360

KW

505

943

453

945

364

823

Fan Efficiency

78.7

86

77.2

86

73.5

85.9

Motor Rating

KW

Fan Shaft Power

CEA Workshop, May - 2005

1050 KW
at 980 rpm

1050 KW
at 980 rpm

Bharat Heavy Electricals Limited, Tiruchy

PA Fan Performance (per fan)


Group I

Group II

Group III

BMCR
DC

Fan
DP

BMCR
DC

Fan
DP

BMCR
DC

Fan
DP

Volume

m3/s

90

164

92.7

196

112.5

225

Head

mmwc

822

1230

927

1270

940

1375

KW

872

2339

979

3032

1206

3631

82

81.5

84.4

77.4

84.1

80

Fan Shaft Power


Fan Efficiency
Motor Rating

CEA Workshop, May - 2005

KW

2575 KW
1480 rpm

3350 KW
1480 rpm

4000 KW
1480 rpm

Bharat Heavy Electricals Limited, Tiruchy

ID Fan Performance (per fan)


Group I

Group II

Group III

BMCR
DC

Fan
DP

BMCR
DC

Fan
DP

BMCR
DC

Fan
DP

Volume

m3/s

376

500

386.2

515

387

535

Head

mmwc

312

440

331

470

335

470

KW

1419

2682

1544

2949

1565

3044

81

79.6

81

79.5

81

80

Fan Shaft Power


Fan Efficiency
Motor Rating

CEA Workshop, May - 2005

KW

3000 KW
at 580 rpm

3250 KW
at 580 rpm

3350 KW
at 580 rpm

You might also like