Download as pdf
Download as pdf
You are on page 1of 76
FOR SERVICE MANUALS. CONTACT MAURITRON TECHNICAL SERVICES see marvon co.uk TEL areca FAX: 01634 - 362554 DIGITAL STORAGE OSCILLCSCOPE 0S1420 Instruction |Manual npGatROT ENE een latte Saas Sere Me ra Contents SECTION 1 Introduction SECTION 2 Specification SECTION 3 Operation 3.1. Connection to the Supply 22 Obtaining a trace 3.3. Setting up the Y channels, 34 Display Modes 3.42. Single Channet 342 Dual Chenee! 242 Add, aaa XY 35 Timebase and X-expansion 36 Trigser 3.7 Store control 37.1 NORM/STORE 37.2 ROLL/REFRESH 2:73 PRETRIGGER/25% + 75% 274 RELEASE 375 ARM 376 mss 327 PLOT 1, PLOT 2 37. DISPLAY HOLD 38 Additional Facilities SECTION 4 Circuit Deseription 44 General 42° The Y amplifier and Beamswiteh 43° Trigger Cicuits 44 Analogue Timebase Generator ‘and Y-Ampiifier 45 Mode Control Circuits 46 The Analogue to Digital Converter 4.7. Timing and Control Logic 48. Store Control 49° Digital to Analogue Converter 4.10 Digital Ramp Generator 4.11 Sampling 4:12 Pot 4.13 Power Supplies SECTION 5 Maintenance 5A General 5.2 Access 5.3 Fault Finding 5.4 Setting Up Procedure SECTION 6 Components Lists and Circuit Diagrams SECTION 7 Guarantee and Service Facilities ILLUSTRATIONS, Block Diagrams Internal Assembly — top view laternal Assembly ~ bottom view Gontro! & Timing Logie Wavetorms Store Control Wavetorms Interconnection Diagrams Y Amplifier Cizeuit Diagram ‘Timebase and Trigger Circuit Diagram Pickoff Circuit Diagram Digital Storage Circuit Diagram Power Supaly and CRT Circuit Diagram Auxiliary Power Suppiy Mechanical Assembly FOR SERVICE MANUALS, CONTACT: MAURITRON TECHNICAL SERVICES www mauritron.co.uk TEL: 01844. 381694 FAX 01846 - 352554 13 2 38 35 37 a1 5 7 51 55 8 Introduction The Gould 051420 provides a combination of Digital Storage and Real-time facilities, and caters for measure ments from DC to 20MHtz with a flicker-ree display of full eyele down to 0.0022, The digital method of storage provides many advantages, notably the facilities for pretrigger viewing and the sblity to store a wave form indefinitely It features two identical input channels with a maximum sensitivity of mV/er and a bandwidth from DC up to 20MHlz. The channels may be displayed separately or together in both STORE and the conventional NORMAL modes. The ability to display the surn or difference of the channels and an X-Y mode operation are available in NORMAL mode, The timebase ranges {rom 0.005ysfom to 0.25/em in NORMAL mode with additional ranges dowa to SOs/em m STORE mode, ‘A.x 10 facility expands the upper limit to SOns/em. In NORMAL and certain of the STORE modes, inde Section 1 pendent variable sensitivity and separate controls ake provided. ‘The trigger facilities available are comprshensive, DC and AC coupling avaiable and a brightline-eee run facility to enable true location in the absence of a trigger. An active TY sync. separator is provided for view ng video waveform Many additional facilities are provided with the OS1420 such as. plot option fitted as standard, a 1KH2 calibrator, a DC coupled Z modulation input and a trace rotation control The instrament is ceadily portable and the use of an uncommitted logic aay has reduced both the number of components and board atea. This has additional benefits in terms of reliability, power consumption and cease of maintenance — wR cm peed pen eet 4

You might also like