Download as xls, pdf, or txt
Download as xls, pdf, or txt
You are on page 1of 2

Percentage of Covered Braiding

G : Percentage of Covered ( % )

G = (2F-F ) x 100
2

F=
sin =

Diameter of cable under braid, D


Number of carriers, c
Number of wire per carrier , N
Diameter of individual wire of braid, d
Pitch of braid ( mm ) , P
Angle of braid with cable axis,
F

Lay Factor
Percentage of Covered , G

N:
c:
d:

Ncd
2 P sin

angle of braid with cable axis ( degree )


P : Pitch of braid

D : Diameter of cable under braid ( mm )

( D ) + P

9.2
24
4
0.28
94
17.5
0.4755
1.071

72.489975

Number of wire per carrier


Number of carriers
Diameter of individual wire of braid ( mm )

mm
pcs
pcs
mm
mm
degree

Percentage of Covered Braiding


G : Percentage of Covered ( % )

G = (2F-F ) x 100
2

F=
sin =

Diameter of cable under braid, D


Number of carriers, c
Number of wire per carrier , N
Diameter of individual wire of braid, d
Pitch of braid ( mm ) , P
Angle of braid with cable axis,
F

Lay Factor
Percentage of Covered , G

N:
c:
d:

Ncd
2 P sin

angle of braid with cable axis ( degree )


P : Pitch of braid

D : Diameter of cable under braid ( mm )

( D ) + P

31.8
24
9
0.4
80
0.7805718801
0.6918004783
1.6240

Number of wire per carrier


Number of carriers
Diameter of individual wire of braid ( mm )

mm
pcs
pcs
mm
mm

90.501305481 %