Professional Documents
Culture Documents
Column Report LIN Amine
Column Report LIN Amine
Document Number:
Job Number:
Client: LIN
Project Nmae: US
Column Service: Absorber
1
Date: 2/7/2014
Prepared by: JJL
Checked by:
Document Revision: A
1
Page:
Column Stages
PFD ref:
P&ID Ref:
Item Number: ~TBD~
-
TopBottom
Column Loadings
4 Vapor Phase
5 Vapor Mass Flow rate
6 Vapor Mass Density
7 Vapor Vol. Flow rate (actual)
8 Vapor Vol. Flow rate (std)
9 Viscosity
10 Liquid Phase
11 Liquid Mass Flow rate
lb/h
4904
4912
4915
4924
4931
4938
4946
4958
lb/ft3
1.6689
1.6583
1.6530
1.6574
1.6668
1.6802
1.6977
1.7215
0.83
0.82
0.82
0.81
0.80
0.012
0.012
0.012
0.012
0.012
ACFS
0.82
0.82
0.83
SCFS
cP
21.90
21.93
21.94
0.012
0.012
0.012
lb/h
2561
2564
2573
2580
2587
2595
2607
2628
lb/ft3
63.95
63.93
64.14
64.36
64.61
64.90
65.24
65.66
gpm
4.99
5.00
5.00
5.00
4.99
4.99
4.98
4.99
sgpm
5.03
5.03
5.05
5.07
5.09
5.11
5.14
5.19
dyn/cm
54.74
54.45
54.17
54.09
54.16
54.39
54.83
55.61
cP
2.576
2.457
2.427
2.472
2.567
2.703
2.884
3.129
16 Liquid Viscosity
17 Total Properties
18 Temperature
19 Pressure
20
136
139
141
141
139
136
133
128
psig
397.0
397.4
397.9
398.3
398.7
399.1
399.6
400.0
Column Details
21 Column Hardware
22 Packing Hardware
23 Tray Type
24 Tray Spacing
Tray
Tray
Tray
Tray
Tray
Tray
Tray
Tray
Sieve
Sieve
Sieve
Sieve
Sieve
Sieve
Sieve
Sieve
2.0
ft
2.0
2.0
2.0
2.0
2.0
2.0
2.0
25 Weir Height
26 Column Diameter (ID)
in
0.5
0.5
3.0
3.0
3.0
3.0
3.0
3.0
in
11.99
12.01
12.02
12.01
11.98
11.95
11.91
11.85
27 Column Area
28 Column Hydraulics - Flooding
ft2
0.78
0.79
0.79
0.79
0.78
0.78
0.77
0.77
29 Capacity/Fractional Flooding
30 System Foam Factor
70.0
70.0
70.0
70.0
70.0
70.0
70.0
70.0
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
gpm/ft2
6.36
6.35
6.35
6.36
6.38
6.41
6.44
6.50
(lb/h)/ft2
6,252
6,239
6,236
6,264
6,299
6,342
6,398
6,474
(ft/s)*(lb/ft3)0.5
1.35
1.35
1.35
1.35
1.35
1.35
1.36
1.36
ft/s
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
psi/ft
0.0386
0.0385
0.0652
0.0654
0.0656
0.0658
0.0662
0.0666
31 Liquid Loading
32 Vapor Loading
33 Additional Column Hydraulics
34 Fs Factor
35 Cs Factor
36 Pressure Drop (per ideal stage)
37 Notes
38
39
40
41
42
43
of
#REF!
Document Number:
Job Number:
Client: LIN
Project Nmae: US
Column Service: Stripper
1
Date: 2/7/2014
Prepared by: JJL
Checked by:
Document Revision: A
2
Page:
of
Column Stages
PFD ref:
P&ID Ref:
Item Number: ~TBD~
-
TopBottom
10
Column Loadings
4 Vapor Phase
5 Vapor Mass Flow rate
6 Vapor Mass Density
7 Vapor Vol. Flow rate (actual)
8 Vapor Vol. Flow rate (std)
9 Viscosity
10 Liquid Phase
11 Liquid Mass Flow rate
lb/h
169
178
297
321
326
328
329
330
331
332
lb/ft3
0.1047
0.1025
0.0869
0.0829
0.0813
0.0805
0.0802
0.0801
0.0802
0.0803
ACFS
0.45
0.48
0.95
1.08
1.12
1.13
1.14
1.14
1.15
1.15
SCFS
cP
0.74
0.79
1.55
1.92
1.92
1.92
1.92
1.92
1.92
1.92
0.015
0.015
0.014
0.014
0.014
0.014
0.014
0.014
0.014
0.014
lb/h
96
2841
2865
2870
2872
2873
2874
2875
2876
2877
lb/ft3
59.26
61.99
61.16
60.78
60.55
60.41
60.31
60.23
60.18
60.13
gpm
0.20
5.71
5.84
5.89
5.91
5.93
5.94
5.95
5.96
5.97
sgpm
0.19
5.60
5.64
5.64
5.64
5.64
5.64
5.65
5.65
5.65
dyn/cm
55.52
45.66
45.06
44.96
44.93
44.92
44.90
44.89
44.87
44.85
cP
0.245
0.687
0.611
0.589
0.578
0.571
0.566
0.562
0.559
0.557
16 Liquid Viscosity
17 Total Properties
18 Temperature
19 Pressure
20
236
245
256
259
261
262
262
263
263
264
psig
17.5
17.7
17.8
18.0
18.2
18.3
18.5
18.7
18.8
19.0
Column Details
21 Column Hardware
22 Packing Hardware
23 Tray Type
24 Tray Spacing
Tray
Tray
Tray
Tray
Tray
Tray
Tray
Tray
Tray
Tray
Sieve
Sieve
Sieve
Sieve
Sieve
Sieve
Sieve
Sieve
Sieve
Sieve
ft
25 Weir Height
26 Column Diameter (ID)
in
27 Column Area
28 Column Hydraulics - Flooding
ft2
29 Capacity/Fractional Flooding
30 System Foam Factor
70.0
70.0
70.0
70.0
70.0
70.0
70.0
70.0
70.0
70.0
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
31 Liquid Loading
32 Vapor Loading
in
gpm/ft2
(lb/h)/ft2
(ft/s)*(lb/ft3)0.5
35 Cs Factor
36 Pressure Drop (per ideal stage)
psi/ft
ft/s
37 Notes
38