Project .

YPFB REFINACION S.A


KAZEN INGENIERIA S.R.L
INYECCION DE GLP CONTAMINADO

23/02/2015

ISO Orifice Plate - Concentric - Flange Taps - Liquid Flow


Tag number
Input data
Fluid
Maximum liquid flow
Normal liquid flow
Flow temperature
Meter inlet pressure
Differential range
SG @ flow conditions
SG @ base conditions
Viscosity @ FTP
Pipe inside diameter
Base pressure
Base temperature
Barometric pressure
Element material
Pipe material

GLP Contaminado
45 USgal/m
22.5 USgal/m
25 degC
265 psig
200 inH2O
.646
.65
.832 cp
2.9 in
14.6959 psia
59 degF
14.7 psia
316 stainless steel
Carbon steel

Output data
Orifice diameter
.866799 in
Beta ratio
.298896
Normal flow differential
50 inH2O
Uncertainty percent
.6929 percent
Reynolds number
19149
Max pressure loss
175.5 inH2O
Max power loss
.1677 hp
Minimum plate thickness
.125 in
Thermal expansion factor
1.00007
Discharge coefficient
.601986
Modified Volume English, basic calculation, calculate size
Source - ISO 5167-2:2003. Orifice plates
InstruCalc Ver.8.1.8.
Notes

1FE-50101

By A.Aguilera
App A.Ustariz