Professional Documents
Culture Documents
PART - A Multiple Choice/true or False/Fill in The Blanks 1 - Mark Each
PART - A Multiple Choice/true or False/Fill in The Blanks 1 - Mark Each
PART - A Multiple Choice/true or False/Fill in The Blanks 1 - Mark Each
PART A
1.
Mid-Exam
In a 3-phase, 400V, balanced star connected system, the voltage between the neutral and ground
is _________.
(a) 400V
(b) 0 V
(c) 230 V
(d) 250V
2.
Three loads, each of resistance 100 are connected in Star to a 415 V, 3 phase, 50 Hz AC
supply. The Total Power is given by
a.) 923.7596 W
b.) 1.7222 kW
c.) 2.9830 kW
d.) 1.660 kW
3.
4.
5.
If phase voltage of a 3-phase delta connected system is 415 V, then line voltage is ___________.
6.
The minimum number of wattmeter required to measure balanced power for a three phase
system is ________
7.
8.
9.
(True/False)
(True/false)
10. Step-down transformer is one which receives A.C. electrical supply at one voltage, and delivers it
at a higher voltage.
(True/False)
Page 1 of 3
Electrical Technology
Mid-Exam
PART B
Answer All Questions
1.
An ideal 50KVA transformer has 800 turns on the primary winding and 80 turns on the
secondary winding. The primary is connected to 1100V, 50Hz supply. Calculate
(i) primary and secondary currents on full-load
(ii) secondary emf and
(iii) the maximum core flux
(3 marks)
2.
A transformer takes a current of 0.6A and absorbs 64W when primary is connected to its
normal supply of 200V, 50Hz; the secondary being on open circuit. Calculate
(i) the magnetizing current and
(ii) iron loss current
(2 marks)
Page 2 of 3
Electrical Technology
Mid-Exam
3.
A balanced 3-phase, delta-connected load has per phase impedance of (25+j40) . If 400V, 3phase supply is connected to this load, Calculate
(i) phase current
(ii) line current and
(iii) power supply to the load
(3 marks)
4.
A 3-phae star connected load consumes a power of 120KW, taking a lagging current of 200A
at a line voltage of 400V, 50 Hz , Calculate
(i) power factor
(ii) phase current
(iii) resistance per phase and
(iv) reactance per phase
(2 Marks)