Download as pdf or txt
Download as pdf or txt
You are on page 1of 20

ALC plus

FW upgrade procedure
from versions 01.00.01/01.01.00 to version 01.02.02

UPGRADE
PROCEDURE
Property of
Siae Microelettronica
All rights reserved.

UPGRADE FROM N0001L-01


001/100 TO 202

Written by

Approved by

Date

Page

Lab. VIO

F. Chiesa

29/09/2009

1 of 20

Document id

UP.N0001L

Rev./Ver.

03

Table of contents

1
2
3
4
5
5.1
5.2
5.3
6
6.1
6.2
7
7.1
7.2
8

UPGRADE
PROCEDURE
Property of
Siae Microelettronica
All rights reserved.

Introduction .............................................................................................................................. 3
Present versions........................................................................................................................ 3
New version ............................................................................................................................. 4
Preliminary check .................................................................................................................... 5
SW upgrade with SCT ............................................................................................................. 6
Preliminary set-up ................................................................................................................ 6
N90566 Equipment Controller application download ...................................................... 8
N96101 WebLCT download ............................................................................................. 9
SW upgrade with WebLCT.................................................................................................... 10
Preliminary set-up .............................................................................................................. 10
N90566 Equipment Controller application download .................................................... 12
WebLCT upgrade ................................................................................................................... 17
Preliminary set-up .............................................................................................................. 17
N96101 WebLCT download ........................................................................................... 17
Final check ............................................................................................................................. 20

UPGRADE FROM N0001L-01


001/100 TO 202

Written by

Approved by

Date

Page

Lab. VIO

F. Chiesa

29/09/2009

2 of 20

Document id

UP.N0001L

Rev./Ver.

03

Introduction

The object of this document is to define a procedure to upgrade ALC plus radio links from system versions PRALPI10
01.00.01 or PRALPI11 01.01.00 to system version 01.02.021 The upgrade is traffic affecting: this procedure minimizes
the duration of traffic interruption. The upgrade procedure covers also the WebLCT upgrade from versions 01.00.0x2 or
01.01.00 to version 01.01.01
This procedure is applicable to each ALC plus equipment of the network: it is presented as a procedure applicable using
the SCT/LCT, both from a local connection or from a remote one, or the WebLCT. All the download durations reported
in this document refers to a LAN connection between PC and equipment.

Present versions

The version of the software modules affected by the upgrade are the following:
PRALPI11 01.00.01
SIAE CODE
N90566
N90609
N90610

WebLCT 01.00.02
SIAE CODE
N96101
PRALPI11 01.01.00
SIAE CODE
N90566
N90609
N90610

WebLCT 01.01.00
SIAE CODE
N96101

1
2

VERSION
01.00.01
01.07.58
01.07.58
01.00.02
01.00.21

FILE DESCRIPTION
Equipment controller appl.
FPGA 1+0
FPGA 1+1
Conf. Baseband
Conf. Modem

VERSION
01.00.02

WebLCT

VERSION
01.01.00
01.07.58
01.07.58
01.00.02
01.00.25

FILE DESCRIPTION
Equipment controller appl.
FPGA 1+0
FPGA 1+1
Conf. Baseband
Conf. Modem

VERSION
01.01.00

FILE DESCRIPTION

FILE DESCRIPTION

WebLCT

This procedure is applicable also for upgrading to system version PRALPI12 01.02.00.
Where x can be 1, 2 or 3.

UPGRADE
PROCEDURE
Property of
Siae Microelettronica
All rights reserved.

UPGRADE FROM N0001L-01


001/100 TO 202

Written by

Approved by

Date

Page

Lab. VIO

F. Chiesa

29/09/2009

3 of 20

Document id

UP.N0001L

Rev./Ver.

03

New version

The version of the software modules after the upgrade will be the following:
PRALPI12 01.02.02
SIAE CODE
N90566
N90609
N90610

WebLCT 01.01.02
SIAE CODE
N96101

UPGRADE
PROCEDURE
Property of
Siae Microelettronica
All rights reserved.

VERSION
01.02.01
01.08.13
01.08.13
01.00.03
01.00.26

FILE DESCRIPTION
Equipment controller appl.
FPGA 1+0
FPGA 1+1
Conf. Baseband
Conf. Modem

VERSION
01.01.02

WebLCT

FILE DESCRIPTION

UPGRADE FROM N0001L-01


001/100 TO 202

Written by

Approved by

Date

Page

Lab. VIO

F. Chiesa

29/09/2009

4 of 20

Document id

UP.N0001L

Rev./Ver.

03

Preliminary check

Before starting the upgrade procedure be sure of the status of the equipment to be downloaded. In the SCT window
Current alarms verify the absence of internal alarms, i.e. alarms related to:
hardware module failures
software module failure
hardware or software mismatch
units not responding.
If the download is performed on a terminal connected to the SCT via the PPP radio, verify also the absence of any alarm
related to the radio connection, i.e.:
RX power low
TX power low
HBER, LBER or EWL.
The presence of any other kind of alarm must in any case be justified and its cause known before proceeding with the
download procedure.
We suggest not to perform the upgrade in presence of alarms.
In any case, even if no alarm is present, save the Fault Report (generated via the SCT or the WebLCT) as a reference, to
verify after the upgrade that no further alarms appeared and to have a reference about the inventory.
To assure the possibility to perform a downgrade back from 01.02.02 to 01.00.01/01.01.00 versions, or in any case to
recover the equipment if something goes wrong during the upgrade, before performing the download of version
01.02.02 you must save all the configuration data (using the SCT Configuration Wizard or the Backup/Restore function
of WebLCT).
Note: Saving the configuration before proceeding with the download of a new version is always recommended, even if
no downgrade is foreseen.

UPGRADE
PROCEDURE
Property of
Siae Microelettronica
All rights reserved.

UPGRADE FROM N0001L-01


001/100 TO 202

Written by

Approved by

Date

Page

Lab. VIO

F. Chiesa

29/09/2009

5 of 20

Document id

UP.N0001L

Rev./Ver.

03

SW upgrade with SCT

In the following chapters a list of the necessary downloads is provided. Please, be sure to have read previous chapter 4
before performing the upgrade. To perform the SW upgrade with the WebLCT please refer to chapter 6.
5.1
Preliminary set-up
All downloads must be performed with the SCT connected as System. The local equipment (the one the SCT is
physically connected to) is usually connected as System during the SCT connection procedure, while if you need to
download remote equipment, you must perform a Login. After clicking on the equipment in the Alarm Summary /
ManOP / Station section of the SCT window, click on the Login button in the toolbar (see Figure 1)

Figure 1
The Remote Login window shall pop-up (see Figure 2). Insert SYSTEM as User, SIAEMICR as Password and click on
the OK button: the selected equipment shall be connected as System.

Figure 2
To perform a download you have to open the SCT window Version. Right-click with your mouse on the relevant
equipment, in the Alarm Summary / ManOP / Station section of the SCT window, and select the Version item in
the pop-up menu that shall appear, as shown in Figure 3.

UPGRADE
PROCEDURE
Property of
Siae Microelettronica
All rights reserved.

UPGRADE FROM N0001L-01


001/100 TO 202

Written by

Approved by

Date

Page

Lab. VIO

F. Chiesa

29/09/2009

6 of 20

Document id

UP.N0001L

Rev./Ver.

03

Figure 3
A window similar to the one shown in Figure 4 shall appear (please note that some of the displayed information e.g.
the versions - will be different from the example).

Figure 4
In one bench you will have, as the running software version, PRALPI10 01.00.01 or PRALPI11 01.01.00. The other
bench could be Loaded or Not Loaded.
From now on you can start the downloading procedure: click on the Download SW Setup button.

UPGRADE
PROCEDURE
Property of
Siae Microelettronica
All rights reserved.

UPGRADE FROM N0001L-01


001/100 TO 202

Written by

Approved by

Date

Page

Lab. VIO

F. Chiesa

29/09/2009

7 of 20

Document id

UP.N0001L

Rev./Ver.

03

5.2

N90566 Equipment Controller application download

In the SCT window Download setup select download type Forced. Choose the correct Download file path where the
file n90566.dwl is present on your PC (see as an example the following Figure 5: please note that the path in the
example may not correspond to the one you have).

Figure 5
Press Start to execute the download. Confirm the command clicking on the Proceed to download? button, like in
Figure 6.

Figure 6
A window similar to the following will appear, giving the status of the download (the actual name of the equipment and
path to the file will be different from the ones shown in Figure 7):

Figure 7
After starting the download, the relevant Status message is present in the log window of the SCT.
During the download the Downloading Warning is present in the summary panel.

UPGRADE
PROCEDURE
Property of
Siae Microelettronica
All rights reserved.

UPGRADE FROM N0001L-01


001/100 TO 202

Written by

Approved by

Date

Page

Lab. VIO

F. Chiesa

29/09/2009

8 of 20

Document id

UP.N0001L

Rev./Ver.

03

At the end of the download the relevant Status message (Software Download Completed) is present in the log window
of the SCT, and the new Software Version is present in the previously unused bench of the Equipment Software
Version window of the SCT (you could need to close and re-open this window to allow its content to be updated).
Important note: if a Software Download Aborted message is present in the log window of the SCT or if the
Software Download Completed message is not present, the download has not been properly performed.
When the download is completed click on the Bench Switch button to switch on the new memory bench (see Figure 8).

Figure 8

5.3

N96101 WebLCT download

The WebLCT download is covered in chapter 7

UPGRADE
PROCEDURE
Property of
Siae Microelettronica
All rights reserved.

UPGRADE FROM N0001L-01


001/100 TO 202

Written by

Approved by

Date

Page

Lab. VIO

F. Chiesa

29/09/2009

9 of 20

Document id

UP.N0001L

Rev./Ver.

03

SW upgrade with WebLCT

In the following chapters a list of the necessary downloads is provided. Please, be sure to have read previous chapter 4
before performing the upgrade. To perform the SW upgrade with the SCT please refer to chapter 5. To perform the
download an FTP server must be running on the PC where the firmware is located: this is automatically attained if you
connect to WebLCT from the WLC (WebLCT Console) or from the SCT.
6.1
Preliminary set-up
All downloads must be performed with the WebLCT connected as System. The local equipment (the one the WebLCT
Console is physically connected to) is usually connected as System during the WebLCT login procedure, while if you
need to download remote equipment, you must perform a Login. To login on the remote equipment click on the Login
tab in the upper right part of the WebLCT window (see Figure 9).

Figure 9
The Change Login window shall pop-up. Insert SYSTEM as User, SIAEMICR as Password and click on the Login
field: the remote equipment shall be connected as System.
To perform a download you have to click on the Software info & Maintenance item in the WebLCT main menu. The
Software Info & Maintenance window shall appear, as shown in Figure 10.

UPGRADE
PROCEDURE
Property of
Siae Microelettronica
All rights reserved.

UPGRADE FROM N0001L-01


001/100 TO 202

Written by

Approved by

Date

Page

Lab. VIO

F. Chiesa

29/09/2009

10 of 20

Document id

UP.N0001L

Rev./Ver.

03

Figure 10
Click on the Download SW setup tab: a window similar to the one shown in Figure 11 shall appear (please note that
some of the displayed information e.g. the versions or the use of memory benches- could be different from the
example).

UPGRADE
PROCEDURE
Property of
Siae Microelettronica
All rights reserved.

UPGRADE FROM N0001L-01


001/100 TO 202

Written by

Approved by

Date

Page

Lab. VIO

F. Chiesa

29/09/2009

11 of 20

Document id

UP.N0001L

Rev./Ver.

03

Figure 11
In one bench you will have, as the running software version, PRALPI10 01.00.01 or PRALPI11 01.01.00. The other
bench could be Loaded or Not Loaded.
From now on you can start the downloading procedure.
6.2

N90566 Equipment Controller application download

In the WebLCT window Sw Download select download type Forced. Click on the Browse local system field to
specify the file to be dowloaded: in the window that will pop-up browse your filesystem and select the file n90566.dwl
(see as an example the following Figure 12: please note that the path in the example may not correspond to the one you
have).
Warning: the path to file n90566.dwl can contain only standard ASCII characters, without accented characters or
similar. If characters other than standard ASCII characters are present the download may fail.

UPGRADE
PROCEDURE
Property of
Siae Microelettronica
All rights reserved.

UPGRADE FROM N0001L-01


001/100 TO 202

Written by

Approved by

Date

Page

Lab. VIO

F. Chiesa

29/09/2009

12 of 20

Document id

UP.N0001L

Rev./Ver.

03

Figure 12
Click on the Open button to confirm the choice: the selected path will be shown in the Download file path field as in
the following Figure 13.

Figure 13
Press Start to execute the download. Confirm the command clicking on the Yes button, like in Figure 14.
UPGRADE
PROCEDURE
Property of
Siae Microelettronica
All rights reserved.

UPGRADE FROM N0001L-01


001/100 TO 202

Written by

Approved by

Date

Page

Lab. VIO

F. Chiesa

29/09/2009

13 of 20

Document id

UP.N0001L

Rev./Ver.

03

Figure 14
An indication will appear as bench status, showing that the download is going on (see Figure 15):

UPGRADE
PROCEDURE
Property of
Siae Microelettronica
All rights reserved.

UPGRADE FROM N0001L-01


001/100 TO 202

Written by

Approved by

Date

Page

Lab. VIO

F. Chiesa

29/09/2009

14 of 20

Document id

UP.N0001L

Rev./Ver.

03

Figure 15
After starting the download, the relevant Status message is present in the Event list of the WebLCT.
During the download the Downloading Warning is present in the WebLCT summary panel.
At the end of the download the relevant Status message (Download Started) is no more active in the Event list of the
WebLCT, and the new Software Version is present in the previously unused bench of the Software Info & Maintenance
window of the WebLCT (you could need to click on the Refresh button to allow its content to be updated).
Important note: if a Software Download Aborted message is present in the Event list of the WebLCT, the download
has not been properly performed.
When the download is completed click on the Bench Switch Tab to switch on the new memory bench (see Figure 16).

UPGRADE
PROCEDURE
Property of
Siae Microelettronica
All rights reserved.

UPGRADE FROM N0001L-01


001/100 TO 202

Written by

Approved by

Date

Page

Lab. VIO

F. Chiesa

29/09/2009

15 of 20

Document id

UP.N0001L

Rev./Ver.

03

Figure 16
During the bench switch the equipment will be disconnected from the WebLCT.

UPGRADE
PROCEDURE
Property of
Siae Microelettronica
All rights reserved.

UPGRADE FROM N0001L-01


001/100 TO 202

Written by

Approved by

Date

Page

Lab. VIO

F. Chiesa

29/09/2009

16 of 20

Document id

UP.N0001L

Rev./Ver.

03

WebLCT upgrade

In the following chapters the WebLCT upgrade is described.


7.1
Preliminary set-up
All downloads must be performed with the WebLCT connected as System. The local equipment (the one the WebLCT
Console is physically connected to) is usually connected as System during the WebLCT login procedure, while if you
need to download remote equipment, you must perform a Login. To login on the remote equipment click on the Login
tab in the upper right part of the WebLCT window (see Figure 17).

Figure 17
The Change Login window shall pop-up. Insert SYSTEM as User, SIAEMICR as Password and click on the Login
field: the remote equipment shall be connected as System.
7.2

N96101 WebLCT download

To perform a download you have to click on the Software info & Maintenance item in the WebLCT main menu. The
Software Info & Maintenance window shall appear, as shown in Figure 18.

UPGRADE
PROCEDURE
Property of
Siae Microelettronica
All rights reserved.

UPGRADE FROM N0001L-01


001/100 TO 202

Written by

Approved by

Date

Page

Lab. VIO

F. Chiesa

29/09/2009

17 of 20

Document id

UP.N0001L

Rev./Ver.

03

Figure 18
Click on the Web LCT tab: a window similar to Figure 19 will be shown.

UPGRADE
PROCEDURE
Property of
Siae Microelettronica
All rights reserved.

UPGRADE FROM N0001L-01


001/100 TO 202

Written by

Approved by

Date

Page

Lab. VIO

F. Chiesa

29/09/2009

18 of 20

Document id

UP.N0001L

Rev./Ver.

03

Figure 19
Click on the Browse button to browse your filesystem and select file Webs_16_N96101_1.1.2.tar. In the WebLCT
windows youll see the status change to Ready to upload Webs_16_N96101_1.1.2.tar.
Click on the Upload button and confirm clicking on the Yes button.
The WebLCT download will start and the status of the download will be shown. At the end of the download the
following message will appear:

UPGRADE
PROCEDURE
Property of
Siae Microelettronica
All rights reserved.

UPGRADE FROM N0001L-01


001/100 TO 202

Written by

Approved by

Date

Page

Lab. VIO

F. Chiesa

29/09/2009

19 of 20

Document id

UP.N0001L

Rev./Ver.

03

Final check

After the upgrade procedure is finished, verify the status of the equipment by opening the SCT window Current
alarms or looking at the WebLCT Event list and verifying the absence of alarms.
If before starting the upgrade procedure some alarms were present, compare the list of the current alarms with the
previously saved ones.
If any new alarm is present, perform the download of the previously saved configuration, using the SCT Configuration
Wizard, in the Tools menu, or the Backup/Restore Configuration function of the WebLCT and then verify again the
alarm status.

UPGRADE
PROCEDURE
Property of
Siae Microelettronica
All rights reserved.

UPGRADE FROM N0001L-01


001/100 TO 202

Written by

Approved by

Date

Page

Lab. VIO

F. Chiesa

29/09/2009

20 of 20

Document id

UP.N0001L

Rev./Ver.

03

You might also like