WeighMax W-EX650C Mini Scale Manual

You might also like

Download as pdf
Download as pdf
You are on page 1of 3
Pecks Secle @ W-EX650C Made in China W-EX650C Digital Scale instruction Manual =a Se parm ¢ au J Specification = ws 1.2 Graduation 0.1 1.3 Overload: 6608 1.4 Four nits for options: a/er/oat/et 1.5 Low battery indication 1.6 Auto power off in 605 LT Operates on 2 AMA 1.5Y battery 2 Key function 21 CWO : tum on oF turn off the scale 22 MME: shift che unit 23. TARE : Dreset the LO display to 0.0 2) weighs the 2 item only without weighing or removing the 1* itea. Sunstruction: 3.1'Tum on the scale , the 10D ill show the whole picture “S88H8" and then “O.0g” . It moans the scale Ss ‘Otherwise the scale will show “E8888” all the tine Gio whole picture “6 Cao 3.2 If not in use, the scale would automtically turn off in 60s. 3.3 If overload, the LCD display will show “O La” . “Crerlond tndlcatTan> 3.4 If low battery, the LOD display willl show “Lo' ‘ow battary Tadlcatien? 3.5 When the reading is stable, the sign of “hold” will be on the top left of the LCD. (tai = indication) 4 Operation detaits “401 Open the hattery cover at the back of the scale, put 2A 1.5¥ battery inside and put back the battery cover. Place the scale on a level floor, take off the transparent cover. 4.2Press “ON/OFF” to turn on the scale. When stable, the LOD display will show “0.04”. 4.3 Press “MODE” to select the unit in nirinin firinin., nn » vy we WALLED | | ow ioud =e Mise 4.APlace the item in the middle of the scale platform (Cake 20g as an example), when stable the sign “hold” will be show in the top left of LCD and the accurate weight of the item. [eas] [eves] (63 [_isae| Toit os Taig m0 Rey 4.5 IF the LED Is not 0.0 before woighing .please press “TARE ‘rill be show on the left LCD ni Lt ae Toe EO tafe seating (ores “TARE 4.6 thon the scale te not in use, please pres maar “QVOFF™ to turn off the soale and put ick the transparent cover S. Calibration 1 Turner the scale and press"MNE” for seconds. the UDwill show "CAL", release the “MIDE key, press “MAE” to calibrate ZERO. [OO tee Ta) (pres “MUe™) (tow TOA pre 5.2 Then the LG will show "200.08", please put’ 200g weight in the aiddle of the scale platform. If calibration iis OK, the LOD will show “PASS” | Otherwise it will Flash “200,09” all the time. When this happens, please (CB calibration wlahe) 16.1 Please pat the scale on a level floor. 6.2 Do not use the scale when shaking. 16.3 Do not overload, otherwise the scale would be damaged. 6.4 If the LCD is not 0.0, please press “TARE” 165 Please place the item in the middle of the scale platform in order to get the accurate weight. 6.6 Please keep the scale in room toaperature. 67 If the LOD show “Lo”, please change the battery. 6.8 Please tun off the scale when the scale is not in use

You might also like