Abbreviated Last Measurement Summary

************************************
Database:
Area:

SBGAST.rbm
Jockey Pump

M1
H
M1V
M1A

P5330B

M2H
M2V
M2A

- Jockey Pump
M1H
M1P
M1D
M1V
M2H
M2P
M2D
M2V
M2A
P1H
P1P
P1V
P1A

P1H
P1V
P1A

(28-Jan-15)
OVERALL LEVEL
.474 mm/Sec
.063 G-s
.034 G-s
.290 mm/Sec
.556 mm/Sec
.278 G-s
.178 G-s
.559 mm/Sec
.580 mm/Sec
1.158 mm/Sec
3.553 G-s
1.713 mm/Sec
1.085 mm/Sec

Data tabulated above is the recent vibration measurement for P5330B. No previous measurement was
performed as the unit is not included in the list of equipment for vibration monitoring. As request by
operation representative, a vibration measurement was made on both unit P5330A and P5330B to
confirm there are defective bearing on the P5330B as there is an abnormal sound coming from the
pump side. Although the overall reading is not high at all location, the pump Peakvue, P1P spectrum
level is high with 3.55 G-s.

Multiple-spectrum above show there are significant amount of high frequency energy appeared at all
pump direction.

A single spectrum P1H with its waveform shown above with the turning speed (1xTS) has been marked,
also there are two non-synchronous peak arise, 5.31XTS and 7.31XTS possibly the bearing fault
frequency. Significant energy is evident in the waveform above with more than 10 G swing.

The spectrum above also show the bearing fundamental frequency (14.8xTS) has been marked with red
vertical lines, with its sidebands arises (Different frequency, Dfrg = 3001.4 CPM = 1xTS). Based on the
turning speed sidebands, an inner race defect is suspected.

Figure above shows the spectrum and its waveform from vertical direction. 2xTS is dominant on the
spectra, possibly there is a cracked inner race. The waveform also show high G swing with more than 16
G-s.
Data Analysis

Elevated non-synchronous and high frequency peaks


High peakvue level.
Repetitive waveform with high G swing

Diagnosis
Inner race bearing defect

Corrective action
The site representative has observed the abnormal sound coming from the pump side. CBM
team has been requested to confirm the possible fault, a bearing fault suspected and they
decided to change the bearing on the same day. CBM team will verify the vibration level after
the bearing has been changed on next routine. These two pumps P5330A & P5330B will be
included in quarterly vibration routine survey.

Reported by:
Fazli