Ac Energy Meter: EE 2192 Laboratory Practice IV
Ac Energy Meter: EE 2192 Laboratory Practice IV
Laboratory Practice IV
AC ENERGY METER
Name
Index No
Group
Date of Per
Date of Sub
Field
:
:
:
:
:
:
PERERA H.G.S.K
120463N
G - 13
2014/12/17
2015/01/14
Electrical
Engineering
CALCULATIONS
Let the time taken for n revolutions be T sec and the wattmeter reading be P watts
Measured meter constant
1000
3600
36105
rev/kWh ( given )
=0
= 1A
= 160 W
= 37.4 s
136105
16037.4
( )100%
= 601.60
rev/kWh
601.60 600
100 = .26 %
600
Similarly
= 00
= -300
= 300
Current
(A)
Error (%)
Error (%)
Error (%)
601.60
.26
552.83
-7.86
607.28
1.21
594.84
-0.86
571.43
-4.76
591.72
-1.38
608.52
1.42
592.89
-1.19
545.45
-9.1
606.67
1.12
518.58
-13.56
569.44
-5.09
594.84
-0.86
618.13
3.021
577.66
-3.72
|Error (%)|
=0
= -30
= 30
.26
7.86
1.21
.86
4.76
1.38
1.42
1.19
9.1
1.12
13.56
5.09
0.86
3.02
3.72
14
13
12
11
10
0
1
5
CURRENT (A)