Professional Documents
Culture Documents
Motor Starter Circuit
Motor Starter Circuit
Wiring
Class 14
3 Phase and 1 Phase Magnetic Starters
Ambient Compensated
Single Phase Sizes 00212
Ambient Compensated
3 Phase Sizes 004
CIRUIT
PROTECTION
DEVICE
(IF USED)
NEMA and HP
Rated Control
CIRCUIT
PROTECTION
DEVICE
(IF USED)
MOTOR
MOTOR
For
157
Siemens Industrial Control Products
Wiring
Class 17, 18
Three Phase Solid State and Thermal Overloads
Size 412, 5
Size 04
TO SUPPLY
L1
L2
L3
B
3
A
CONTROL FUSES
(OPTIONAL)
M W
1
T1
T2
CIRUIT
PROTECTION
DEVICE
(IF USED)
ALTERNATE
CONNECTIONS FOR
TRANSFORMER
DISCONNECT or
CIRCUIT BREAKER
T3
OVERLOAD RELAY
NEMA and HP
Rated Control
95
"C"
T2
T1
SEC FUSE
XF
H4
96
T3
MOTOR
X1
H2
SEC
H3
X2
H1
Size 6, 7
CIRCUIT
PROTECTION
DEVICE
(IF USED)
MOTOR
158
Siemens Industrial Control Products
Wiring
Class 22
Three Phase Solid State Overload
Size 412, 5
Sizes 24
Sizes 0134
INCOMING LINE
CIRCUIT
PROTECTIVE
DEVICE
(IF USED)
"REV"
CONTACTOR
"FWD"
"FWD"
CONTACTOR
CONTRACTOR
MECHANICAL
INTERLOCK
CURRENT
TRANSFORMER
(WHEN USED,
SEE TABLE)
O.L.
RELAY
(IF USED)
NEMA and HP
Rated Control
Sizes 04
159
Siemens Industrial Control Products
Wiring
Class 25, 26
3 Phase Overloads
Size 04
TO SUPPLY
L1
L2
L3
ALTERNATE CONNECTIONS
FOR TRANSFORMER
DISCONNECT or
CIRCUIT BREAKER
B
A
3
10
9
V FOR W
6 5
8
V REV W
4
T1
T2
T3
CONTROL FUSES
(OPTIONAL)
OVERLOAD RELAY
95
SEC FUSE
XF
H4
96
NEMA and HP
Rated Control
T2
T1
X1
H2
SEC
H3
T3
X2
H1
Size 412, 5
INCOMING LINE
CIRCUIT
PROTECTIVE
DEVICE
(IF USED)
"REV"
CONTACTOR
"FWD"
"FWD"
CONTACTOR
CONTRACTOR
MECHANICAL
INTERLOCK
CURRENT
TRANSFORMER
(WHEN USED,
SEE TABLE)
O.L.
RELAY
(IF USED)
160
Siemens Industrial Control Products
Wiring
TO SUPPLY
TO SUPPLY
L1
L2
L1
L3
L2
L3
DISCONNECT or
CIRCUIT BREAKER
ELEMENTARY DIAGRAM
DISCONNECT or
CIRCUIT BREAKER
WIRING DIAGRAM
T4
HI
T6
OL-HI
HI
LO
T3
T4
T1
LO
HI
T5
T5
LO
T1
T6
T2
CONSTANT HORSEPOWER
MOTOR
OL-LO
LO
T2
6 5
LO
1
3 8
V HI W
V LO W
T3
ALL OL'S
96
95
1 STOP
HIGH
LO
8
HI
OVERLOAD RELAY
HI
95
LOW
T1
HI
96
T2
OVERLOAD RELAY
95
96
T6
T3
T5
LO
T4
LO
POSITION L1 L2 L3 TOGETHER
LOW SPEED T1 T2 T3 T4 T5 T6
HIGH SPEED T6 T4 T5
T1
T2
T3
T4
T5
T6
MOTOR
NEMA and HP
Rated Control
TO SUPPLY
L1
L2
L1
L3
DISCONNECT or
CIRCUIT BREAKER
L2
L3
DISCONNECT or
CIRCUIT BREAKER
ELEMENTARY DIAGRAM
T4
WIRING DIAGRAM
HI
T6
L
OL-HI
HI
HI
T3
T4
T1
L
T5
T5
LO
T1
LO
T2
8
V L W
T6
T4
T5
OVERLOAD RELAY
LO
V HI W
T6
T2
CONSTANT HORSEPOWER
MOTOR
OL-LO
95
T3
96
ALL OL'S
96
1
95
STOP
HIGH
LO
8
HI
HI
1
LOW
HI
7
L
LO
V LO W
LO
T1 T2
POSITION L1 L2 L3 TOGETHER
LOW SPEED T1 T2 T3 T4 T5 T6
HIGH SPEED T6 T4 T5
T3
OVERLOAD RELAY
95
96
T1
T2
T3
T4
T5
T6
MOTOR
TO SUPPLY
L1
L2
TO SUPPLY
ELEMENTARY DIAGRAM
L3
L1
DISCONNECT or
CIRCUIT BREAKER
LO
HI
OL-LO
T2
HI
LO
T3
T2
T5
WIRING DIAGRAM
L3
T1
T3
T1
LO
L2
DISCONNECT or
CIRCUIT BREAKER
T4
T6
HI
T6
HI
6 5
OL-HI
T2
T5
T5
95
1 STOP
LOW
HI
OVERLOAD RELAY
95
LO
T6
5
LO
6
LO
HIGH
1
3 8
V LOW W
V HIGH W
T6
ALL OL'S
96
T1
T3
T4
HI
96
T4
OVERLOAD RELAY
95
T1
T5
96
T3
T2
HI
HI
POSITION L1 L2 L3 TOGETHER
LOW SPEED T1 T2 T3
HIGH SPEED T6 T4 T5 T1 T2 T3
T1
T2
T3
T4
T5
T6
MOTOR
161
Siemens Industrial Control Products
Wiring
L2
TO SUPPLY
T4
L3
L1
DISCONNECT or
CIRCUIT BREAKER
ELEMENTARY DIAGRAM
LO
H
OL-LO
LO
LO
T1
T2
T2
T5
V LO W
T2
T5
ALL OL'S
T1 T2
T4
96
T1
T3
OL-HI
T5
8
V H W
T4
T6
HI
WIRING DIAGRAM
T6
HI
HI
L3
CONSTANT TORQUE
MOTOR
T3
L2
DISCONNECT or
CIRCUIT BREAKER
T1
T3
T6
T3
OVERLOAD RELAY
VARIABLE TORQUE
MOTOR
95
96
95
2
1 STOP
LOW
HI
6
LO
LO
A
HIGH
4
1
5
LO
7
H
HI
V HI W
H
HI
2
NEMA and HP
Rated Control
POSITION L1 L2 L3 TOGETHER
LOW SPEED T1 T2 T3
HIGH SPEED T6 T4 T5 T1 T2 T3
T6
T4
T5
OVERLOAD RELAY
95
96
T1
T2
T3
T4
T5
T6
MOTOR
L2
TO SUPPLY
L3
L1
T2
DISCONNECT or
CIRCUIT BREAKER
L2
L3
DISCONNECT or
CIRCUIT BREAKER
ELEMENTARY DIAGRAM
WIRING DIAGRAM
LO
T1
LO
OL-LO
T1
T2
T3
T12
LO
T3
HI
T11
HI
OL-HI
T12
T11
HI
T13
ALL OL'S
2
95
HIGH
4
1 STOP
LO
8
HI
HI
LOW
2
6
T1
HI
T3
OVERLOAD RELAY
95
3
T2
7 4
T11 T12 T13
A
LO
T1
T2
T3
T11
T12
T13
OVERLOAD RELAY
95
96
LO
POSITION L1 L2 L3
LOW SPEED T1 T2 T3
HIGH SPEED T11 T12 T13
8
V HI W
T13
96
V LO W
MOTOR
162
Siemens Industrial Control Products
96
Wiring
2
NEMA and HP
Rated Control
Wye-Delta Starter
Open Transition
Wye-Delta Starter
Closed Transition
163
Siemens Industrial Control Products
Wiring
OPTIONAL
DISCONNECT
OR
CIRCUIT
BREAKER
NEMA and HP
Rated Control
Size 41/27
Part-Winding
CUSTOMER'S INC. LINE
POWER WIRING:
USE 75C, MINIMIUM
COPPER WIRE ONLY.
CIRCUIT
BREAKER
MOTOR
NEMA
164
Siemens Industrial Control Products
Wiring
OPTIONAL
DISCONNECT
OR
CIRCUIT BREAKER
2
NEMA and HP
Rated Control
OPTIONAL
DISCONNECT
OR
CIRCUIT BREAKER
NEMA
NEMA
165
Siemens Industrial Control Products
2
NEMA and HP
Rated Control
INCOMING LINE
CIRCUIT
PROTECTIVE
DEVICE
(IF USED)
"C"
REMOVE WIRE "C" IF
CONTACTOR COIL
IS TO OPERATE ON A
VOLTAGE OTHER THAN
LINE VOLTAGE OR ON A
SEPARATE CONTROL
SOURCE.
CONTACTOR
"B"
CURRENT
TRANSFORMER
O.L.
RELAY
(WHEN USED,
SEE TABLE)
(IF USED)
LOAD
166
Siemens Industrial Control Products
Wiring
Wiring
Class 83, 84
Duplex with Auto Alternation
2
NEMA and HP
Rated Control
167
Siemens Industrial Control Products
Wiring
Class 83, 84
Duplex with Manual Alternation
NEMA and HP
Rated Control
168
Siemens Industrial Control Products
Wiring
Class 87, 88
Elementary Diagram
2
NEMA and HP
Rated Control
Auto Transformer
169
Siemens Industrial Control Products
NEMA and HP
Rated Control
170
Siemens Industrial Control Products
Wiring