Professional Documents
Culture Documents
Two Way Slab Design Formula
Two Way Slab Design Formula
1.Given data:
check
Ly / LX
LX
3.5 m
LY
4.5 m
fck
20 N/mm
fY
415 N/mm2
1.285714 < 2
2.Depth of slab:
As the loading class exceeds the value of 3 kN/m2 , adopt a span /depth ratio of 25
depth =
(span / 25)=
140 mm
so effective depth is
d=
over all depth
D=
140 mm
165 (d + cover 25 mm)
3.Effective span:
effective span =
(clear span + effective depth) =
3.64 m
4.Load calculation:
self wt of slab = (D * 25 *1 * 1)
Live load =
floor finish =
4.125 KN/m2
4
0.6
service load = W =
Design ultimate load = wu = (1.5 * W)
8.725 KN/m2
13.0875 KN/m2
x =
0.077
y =
0.056
M ux =
x * wu * lx2 =
13.35 KN.m
mm
M uy =
y *wu * lx2
V ux =
0.5 * wu * lx
M max =
(0.138 * fck * b * d2 )
9.71 KN.m
23.82 KN
6.Check of depth:
d2 =
d =
4837.7241956522
69.55 mm is less than d hence ok
7. Reinforcement calculations:
Mu =
Ast =
adopt 10 mm dia bar
f y . Astx
f ck .bd
min reinforcement
Ast min = 0.12/100*bd
=
10 mm
78.5
168 mm2
284.8980523256
so 10 mm dia @ 250mm c/c
S=
250
area =
314 mm2
S=
467.2619047619 mm
so 10mm dia @ 300 mm c/c
v =
Vu / bd
=
pt =
0.17
100 Ast/bd
0.22
0.3937
k=
>v
c =
1.27
20
0.22 from FIG 4 of IS 456-2000 Kt=
(L/D)max=
32
(L/D)actual=
26
<
1.6
32
0.31
0.12 percent =
0.0012*10^3*D
=
provide 10mm dia bar at 300mm centres
198 mm2
3373.494
mm2
0.156683
0.843317
0.918323
0.081677
275.5372