Heat Calculation Project Edited (Elma)

You might also like

Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 10

Assume Di

Tube Di =1.5cm @ 0.015m

Lc= 8m

Shell Di = 1.5m

Assume the Tco and Tho

Tcout= 97oC (assumed)


Tcin= 48oC

= mCpT
= (18 kg/s ) x (4.18 kJ/kg.K) x (49K)
= 3686.76 kg/s

Assume that Qc/Qh =1 @Qc =Qh

Qh = MhCph Th , assume that oil is constant at any temperature


3686.76 kJ/s = (35kg/s) x (2.1 kJ/kg.K) x (175- Tho)K
3686.76 kJ/s = (73.5 kJ/s.K) x (175- Tho)K
(175- Tho)K

= 50.16K

-Tho

= -124.84

Tho

= 124.84 oC @ 397.84 K

Area of shell and tube


Tube

= DiL
= (0.015)(8m)
=0.3769 m2

Shell

= DiL
= (1.5) (8m)
= 37.6991m2

Find the velocity of water stream


V

= /PA
= (18kg/s) / (1000kg/m3) x (0.3769m2)
= 0.047758 m/s

Velocity of oil stream


V

= (35 kg/s) / (810.3 kg/m3) x (37.6991m2)


= 1.6284 m/s

Effectiveness

= Q/ Qmax
= Cc (Tco Tci) / Cm n T

Cn

= Mn Cpn
= (35 kg/s) (2440.632)
= 85422.12 W/ oC @ 85.422 kW/ oC

Cc

= Mc Cpc
= (18 kg/s) (4191.5)
=75447 W/ oC @ 75.447 kW/ oC

= Cmin/ Cmax
= 75.447/85.422
= 0.88 kW /oC

Tmax

= Thi Tci
= 175 48 oC
=127 oC

Qmax = Cmin Tmax


= 75.447 kW/ oC x 127 oC
= 9581.769 kW

Rate heat transfer


Q

= Tm/ RT
= 77.4185 oC/ 9.31968 x 10 -3 oC/W
= 8306.991227 W

Correction factor
R Tho-Thi/ Tci-Thi

= (124.84- 175)/ (48 175)


= -50.16 / -127
= 0.3949

P Tci- Tco/ Tho- Thi

= (48 97) /(124.84 175)


=-49/ -50.16
= 0.9768
F = 0.74

Overall heat transfer


U

= (8306 991227)/ (2.4504 x 77.4185 x 0.5)


= 87.57739263 W/ m3. oC

Tf
Cp

Pr
k

Hot fluid (oil)


149.92 oC
2440.632
5.334288 x 10-3
810.352
6.606472 x 10 -6
98.46
0.1327024

Cold fluid (H2O)


72.5 oC
4191.5
3.91 x 10 -4
976.1
2.0205 x 10 -5
2.295
0.665

m/fr
Tin , Tout
Pressure
Enter
Di
Do
L

Shell
35 kg/s
175 oC , 124.84 oC
5.5 bar
Shell = 0.00021 m2. oC/W
1.5m
2.5m
8m

Tube
18 kg/s
48 oC , 97 oC
9 bar
Tube = 0.0005 m2. oC / W
0.015m
0.025m
8m

Area of tube
Assume L = 8m
A

= DL
= (0.025) (8m)
=0.628 m2

Reynold num
Re = VD/

Calculate velocity
V= m / Ac

= (18kg/s) / ( 976.1 kg/ m3) x (2.4504 m2)


= 7.525 x 10 -3 m/s

Re

= VD/
= (7.525 x 10 -5 m/s) (0.015 m) / (2.0205 x 10 -5 m2/s)
= 5.5869

Heat coefficient
h = kNu/ D

Nu for cylinder
Nu

= 0.3 + [ (0.62 Re Pr 1/3) / (1+ (0.4/Pr)2/3)1/4 ]


[ 1+ (Re/ 282000) 5/8 ] 4/5
=0.3 + [ (0.62 (5.5869) (2.295) 1/3) / (1+ (0.4/2.295)2/3)1/4 ]
[ 1+ (5.5869/ 282000) 5/8 ] 4/5
= 0.3 + [ 1.93303/ 1.31202][1.000919636]
= 1.7746785

= kNu/ D
= 0.665 (1.7746785)/ 0.015
= 78.677 W/ m2. oC

NuD formula

Pressure refer to Prandtl number at surrounding temperature


Pressure at 80 oC = 499.3
NuD

= 0.52 (1539.867)0.5 (98.46) 0.36 (98.46 / 499.3) 0.25


= 70.9648

= kNu/ D
=0.1327024 (70.9648) / 1.5
= 6.278 W/ m2. oC

Determine thermal resistance

1
1
RT = +R fi + R wall +R fo+
hi
ho
Since the tubes are thin-walled, the

RT =

Rwall = 0

1
1
+0.0005+ 0+0.00022+
78.677
62.78

= 0.029
Determine the overall heat transfer coefficient, U with fouling factor

U=

U=

1
1
=
RT 1
1
+ R fi + R wall + Rfo +
hi
ho

1
0.029

U= 34.48
Calculated actual area, A
Q=UAF( T m
A=

Q
UF ( T m)

3686760
(34.48)(0.74)(77.4185)

= 1866.38 m 2
Determine Length, L
2

Di L
Tube=
4
2

1866.38
L

(0.015) (L)
4

= 10561550.32m

N=

10561550.32 m
8.0 m

= 1320193

Re = VD/
V

= m/A
= (35kg/s) / [(810.352 kg/m3) x ( 20.6166 m2)]
= 2.094 x 10 -3 m/s

Re

= VD/
= [(2.094 x 10-3 m/s ) x 1.5m] / (6.606472 x 10 -6 m2/s)
= 475.662541

From table 7-2 <arrangement in-line>

Nup = 0.52 Rep 0.5 Pr 0.36 (Pr/Prs)0.25

Vmax = (ST/ ST-D) V


= (0.0217m/ 0.0217m 0.015) (2.094 x 10 -3)
= 6.78206 x 10 -3 m/s
ReD

=Vmax D/
= 6.78206 x 10 -5 (1.5) / (6.606472 x 10 -6)
= 1539.867

Determine LMTD, Tm

Counter flow
1

= Thin Tout
= 175 -97
=78 oC

= Tout Thin
=124.84 48
= 76.84 oC

Tm

= 1 - 2 / (ln (1 / 2))
= (78 76.84) / ln (78/ 76.84)
= 1.16 / 0.01498
= 77.4185 oC

= 75.447 kW / oC (97-48) / (85.422 kW/ oC) (127)


= 0.3407

From table 11-5

Counter flow

NTU

= ( 1 / C-1) ln [ (-1)/( (-1))]


= (1/ 0.88-1) ln [ (0.3407 -1) / (0.3407 x 0.88) -1 ]
= -8.333 ln [ -0.6593/ -0.700184]
= 0.5013

From table 11-4

Counter flow
%

= [ 1- e (-NTU) (1-C)] / [ 1- ce (-NTU ) (1-C)]


= [ 1- e (-0.5013)( 1- 0.88)] / [ 1- 0.88e (- 0.5013) (1 0.88) ]
= 0.05838 / 0.171376
= 0.34065 x 100%
= 34.065

max

= [ 1- e (-NTU )] x 100 %
= 1 e (- 0.5013) x 100 %
= 39.425%