E21 Error: Switch Off Main Switch Switch On Main Switch Again
E21 Error: Switch Off Main Switch Switch On Main Switch Again
E21 Error: Switch Off Main Switch Switch On Main Switch Again
Display: PRC.....
O.K.
Replace:
Display:
E21
Push
Incremental Pulse
Generator
or
Frequency converter
Replace:
Micro 3 PC Board
Display: E 10
RAM Reset
E21
Check :
cable between control
and Reciprocator
Display : E10
Push
Display: Ref
Display : E21
Replace
Proximity Switch
of Reciprocator
Reciprocator is moving
to the Reference point
Reciprocator
is moving fast
in wrong direction
Display :E21
Display : P X.XXX
Exchange
yellow and green wire
of Pulse Generator
Replace:
Incremental Pulse
Generator
or
Frequency Converter
or
Power Supply Board
or check :
Internal Wiring between
PRC-Control and Frequency
converter
Display :
E21
RAM Reset
Replace:
Micro 3 PC-Board