Catalyst Journal Reference Manual For P Series Machine

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

Comprehensive Knowledge Solution

Subject

Catalyst Journal Reference Manual for P Series Machine

Key Words

Journal

Description

Catalyst Journal Reference Manual for P Series Machine

ATM Type

P series machine

Model

P2800,P2801,P5800,P1600

Resource

GTSC

Type

Instruction

Issued by

Allen

Date

2014-05-10

Background:
GRG has developed complete software solution for P series intelligent cash deposit machine.
This solution comprises a terminal application(Catalyst) and a cash collection management
system(aDep). Catalyst is the terminal application running on machine which provides transaction
interface to customer. Catalyst will generate journal data in log file to record transaction or
hardware status information, this document is going to describe how to read journal data.

Preparation:
1. Hardware
GRG P series machine
2. Software
Catalyst: CATalyst3.0R4B469_PSeriesR4B2

Steps:
1. Install Catalyst
1.1
Usually Catalyst is installed in D:\GrgBanking\DTATMW

1.2

Journal log file is stored in D:\GrgBanking\DTATMW\log, file name

GRG Banking Equipment(HK) Co., Ltd.


Page 1 Total 6
Headquarters: 9 Kelin Road, Science City, Luogang District, Guangzhou, China
Hong Kong Office: Unit 10B, 25th Floor, Cable TV Tower, 9 Hoi Shing Road, Tsuen Wan, N.T., Hong Kong
Website: www.GRGBanking.com E-mail: Tech_support@grgbanking.com

format is

Comprehensive Knowledge Solution

JOUyymmdd.txt:
JOU: means journal
yymmdd: means year, month and day, for example 140319 means 19th March, 2014
txt means file extension, can use notepad to open and read
2. Journal data
2.1 application start up
2014-03-19 01:03:51 SYSTEM STARTUP
***********************************
GRGBANKING CATALYST 3.0R4
VER
:V3.4.5,b469
ATM NO. :P0010192
BANK NO. :1792
BRANCH NO.:1000
ATMP
:127.0.0.1:10101 #0
ATMV
:10.1.3.69:8887 #0
LOC
:10.49.213.15
***********************************
(a) Catalyst kernel version:
VER
:V3.4.5,b469
(b) Terminal number:
ATM NO. :P0010192
(c) Bank number:
BANK NO. :1792
(d) Branch number:
BRANCH NO.:1000
(e) Host IP and port:
ATMP
:127.0.0.1:10101 #0
(f) Machine IP:
LOC
:10.49.213.15

2.2: initialize device


Read hopper 1 canister ID: AR000013
Read hopper 2 canister ID: AR000014
Read hopper 3 canister ID: AR000031
Read hopper 4 canister ID: AR000008
CANISTER 1(DENOMINATION:MIXED) IS VALID
CANISTER 2(DENOMINATION:SAR 100) IS VALID
CANISTER 3(DENOMINATION:SAR 100) IS VALID
CANISTER 4(DENOMINATION:SAR 500) IS VALID
CAM8340 iInit Success!
###->Initialize FingerPrint Device Start
###Initialize Failed, ErroCode = 40231
GRG Banking Equipment(HK) Co., Ltd.
Page 2 Total 6
Headquarters: 9 Kelin Road, Science City, Luogang District, Guangzhou, China
Hong Kong Office: Unit 10B, 25th Floor, Cable TV Tower, 9 Hoi Shing Road, Tsuen Wan, N.T., Hong Kong
Website: www.GRGBanking.com E-mail: Tech_support@grgbanking.com

Comprehensive Knowledge Solution


###->Initialize FingerPrint Device End
01:04:26 SAFEDOOR CLOSE!
01:04:26 HANDLE LOCK CLOSE!
01:04:26 FRONT PANEL CLOSE!
(a) CAM8340 cassette ID:
Read hopper 1 canister ID: AR000013
Read hopper 2 canister ID: AR000014
Read hopper 3 canister ID: AR000031
Read hopper 4 canister ID: AR000008
(b) CAM8340 cassette currency and denomination:
CANISTER 1(DENOMINATION:MIXED) IS VALID
CANISTER 2(DENOMINATION:SAR 100) IS VALID
CANISTER 3(DENOMINATION:SAR 100) IS VALID
CANISTER 4(DENOMINATION:SAR 500) IS VALID
(c) Hardware initialization result: CAM8340 device ok; fingerprint device error, error code is 40231
CAM8340 iInit Success!
###->Initialize FingerPrint Device Start
###Initialize Failed, ErroCode = 40231
###->Initialize FingerPrint Device End
(d) Door status: all doors are closed
01:04:26 SAFEDOOR CLOSE!
01:04:26 HANDLE LOCK CLOSE!
01:04:26 FRONT PANEL CLOSE!

2.3 enter into service


/\ 01:04:30 INSERVICE MODE
CAM8340 iDeleteSerialRecords before 2014-02-17
Read hopper 1 canister ID: AR000013
Read hopper 2 canister ID: AR000014
Read hopper 3 canister ID: AR000031
Read hopper 4 canister ID: AR000008
(a) Machine working mode:
INSERVICE MODE
(b) Delete old OCR data:
CAM8340 iDeleteSerialRecords before 2014-02-17
(c) CAM8340 cassette ID:
Read hopper 1 canister ID: AR000013
Read hopper 2 canister ID: AR000014
Read hopper 3 canister ID: AR000031
Read hopper 4 canister ID: AR000008

2.4: start transaction


==>15:15:30 PAN:90001
GRG Banking Equipment(HK) Co., Ltd.
Page 3 Total 6
Headquarters: 9 Kelin Road, Science City, Luogang District, Guangzhou, China
Hong Kong Office: Unit 10B, 25th Floor, Cable TV Tower, 9 Hoi Shing Road, Tsuen Wan, N.T., Hong Kong
Website: www.GRGBanking.com E-mail: Tech_support@grgbanking.com

Comprehensive Knowledge Solution


GET LOGIN START

2.5: cash deposit transaction


Read hopper 1 canister ID: AR000013
Read hopper 2 canister ID: AR000014
Read hopper 3 canister ID: AR000031
Read hopper 4 canister ID: AR000008
iPrepareDeposit Success!
Priority: 421356
Hopper 1 : 10 : 1 ;
Hopper 2 : 100 : 2 ;
Hopper 3 :
Hopper 4 : 500 : 1 ;
BatchID:234526124
TotalCount:4
TotalAmount:710.00
CAM8340 iGetNvNotesInfo return OCR count:4
Set Cash Check Event!
Checking
OCAM8340: Have notes
Cash in cash slot, Set B key to counting
Check Cash Slot Event
Read hopper 1 canister ID: AR000013
Read hopper 2 canister ID: AR000014
Read hopper 3 canister ID: AR000031
Read hopper 4 canister ID: AR000008
iPrepareDeposit Success!
Priority: 421356
Hopper 1 : 10 : 1 ;
Hopper 2 :
Hopper 3 :
Hopper 4 :
BatchID:234526124
TotalCount:5
TotalAmount:720.00
CAM8340 iGetNvNotesInfo return OCR count:1
(a) Prepare deposit: read cassette ID again to ensure cassette is not changed
Read hopper 1 canister ID: AR000013
Read hopper 2 canister ID: AR000014
Read hopper 3 canister ID: AR000031
Read hopper 4 canister ID: AR000008
iPrepareDeposit Success!
Priority: 421356
(b) Deposit details of every cassette: format is denomination : count
GRG Banking Equipment(HK) Co., Ltd.
Page 4 Total 6
Headquarters: 9 Kelin Road, Science City, Luogang District, Guangzhou, China
Hong Kong Office: Unit 10B, 25th Floor, Cable TV Tower, 9 Hoi Shing Road, Tsuen Wan, N.T., Hong Kong
Website: www.GRGBanking.com E-mail: Tech_support@grgbanking.com

Comprehensive Knowledge Solution


Hopper 1 : 10 : 1 ;
Hopper 2 : 100 : 2 ;
Hopper 3 :
Hopper 4 : 500 : 1 ;
(c) Total note count and amount: total result of all times deposit before sending transaction request
TotalCount:4
TotalAmount:710.00
(d) Get OCR data:
CAM8340 iGetNvNotesInfo return OCR count:4
(e) Start checking note thread : if user put notes in entry slot, machine will deposit automatically
Set Cash Check Event!
Checking
OCAM8340: Have notes
Cash in cash slot, Set B key to counting
Check Cash Slot Event
(f) Repeat (a) ~ (e)

2.6: end transaction


<==2014-03-19 15:16:24 NO CARD CDP END

2.7: cashup transaction


11:11:45 SAFEDOOR OPEN!
11:16:19 SAFEDOOR CLOSE!
11:16:19 HANDLE LOCK CLOSE!
11:16:19 FRONT PANEL CLOSE!
Read hopper 1 canister ID: AR000009 Deno:35092
Read hopper 2 canister ID: AR000018 Deno:35111
Read hopper 3 canister ID: AR000015 Deno:35094
Read hopper 4 canister ID: AR000012 Deno:35113
->Enter OCAM8340::bResetSettings
CANISTER 1(DENOMINATION:SAR 10) IS VALID
CANISTER 2(DENOMINATION:SAR 100) IS VALID
CANISTER 3(DENOMINATION:SAR 50) IS VALID
CANISTER 4(DENOMINATION:SAR 500) IS VALID
<-Leave OCAM8340::bResetSettings
<==2014-04-07 11:17:53 NO CARD CDP END
(a) Open door:
11:11:45 SAFEDOOR OPEN!
(b) Change cassette and close door:
11:16:19 SAFEDOOR CLOSE!
11:16:19 HANDLE LOCK CLOSE!
11:16:19 FRONT PANEL CLOSE!
(c) Rewrite cassette currency and denomination
Read hopper 1 canister ID: AR000009 Deno:35092
GRG Banking Equipment(HK) Co., Ltd.
Page 5 Total 6
Headquarters: 9 Kelin Road, Science City, Luogang District, Guangzhou, China
Hong Kong Office: Unit 10B, 25th Floor, Cable TV Tower, 9 Hoi Shing Road, Tsuen Wan, N.T., Hong Kong
Website: www.GRGBanking.com E-mail: Tech_support@grgbanking.com

Comprehensive Knowledge Solution


Read hopper 2 canister ID: AR000018 Deno:35111
Read hopper 3 canister ID: AR000015 Deno:35094
Read hopper 4 canister ID: AR000012 Deno:35113
->Enter OCAM8340::bResetSettings
CANISTER 1(DENOMINATION:SAR 10) IS VALID
CANISTER 2(DENOMINATION:SAR 100) IS VALID
CANISTER 3(DENOMINATION:SAR 50) IS VALID
CANISTER 4(DENOMINATION:SAR 500) IS VALID
<-Leave OCAM8340::bResetSettings

2.8: abnormal: operation timeout


*15:22:57 OPERATION TIMEOUT

2.9: abnormal: hardware error during deposit, will record error code
CAM8340 cashin Failed,Phy = 18109,Log = 18109

Editor:

Allen

Date:

Checked

Date

Approved

Date

2014-05-10

GRG Banking Equipment(HK) Co., Ltd.


Page 6 Total 6
Headquarters: 9 Kelin Road, Science City, Luogang District, Guangzhou, China
Hong Kong Office: Unit 10B, 25th Floor, Cable TV Tower, 9 Hoi Shing Road, Tsuen Wan, N.T., Hong Kong
Website: www.GRGBanking.com E-mail: Tech_support@grgbanking.com

You might also like