Working Load Calculation

You might also like

Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 6

Working load calculation2

Point 1

1. Roof part
Figure below is the plan view of the roof, the circle indicates point 1 and unit is mm.
6100
2696
610

3813

a) Entire roof weight = 6.1m x 3.813m x 2kN/m2 = 46.52kN


Actual roof weight supported on point 1:
Horizontal = 46.52kN/6.1m x 2.696m = 20.57kN
Vertical = 46.52kN/3.813m x 0.61m = 7.442kN
b) Roof beam:
Horizontal beam = 0.15m x 0.55m x 2.696m = 0.22m3 x 24kN/m3
= 5.34kN
Vertical beam = 0.15m x 0.55m x 0.61m = 0.05m3 x 24kN/m3
= 1.21kN
Total = 20.57 + 7.442 + 5.34 + 1.21 = 34.56/2 = 17.28kN

2. First floor column = 0.15m x 0.2m x 3m = 0.09m3 x 24kN/m3 = 2.16kN


3. First floor

a) Slab layout (same with ground floor)


2696

1300

Ly/Lx = 2696/1300 = 2.07>2 (one way slab)


Thus, load is disturbed to longer span, horizontal beam.
- Horizontal: Beam = 0.15m x 0.6m x 2.696m = 0.24m3 x 24kN/m3 = 5.82kN
Slab = 2.696m x 1.3m/2 =1.75m2 x 3kN/m2 = 5.25kN
Brick wall = 0.15m x 3m x 2.6kN/m2 = 1.17kN
-Vertical:

Beam = 0.15m x 0.6m x 1.3m = 0.117m3 x 24kN/m3 = 2.81kN


Brick wall = 0.15m x 3m x 2.6kN/m2 = 1.17kN

b) Sum of horizontal and vertical parts


= 5.82 + 5.25 + 1.17 + 2.81 + 1.17 = 16.22/2
= 8.11kN (load to be transfer to ground floor column)

4. Ground floor column = First floor column = 2.16kN


5. Ground floor = First floor = 8.11kN
Total working load of point 1 = 17.28 + 2.16 + 8.11 + 2.16 + 8.11
= 37.82kN
Point 2 (Car porch)
1. Roof part

Figure below is the plan view of the roof, unit is mm.


6100

Point 2

5277

a) Roof weight = 6.1m x 5.277m = 32.19m2 x 2kN/m2 = 64.38kN


b) Roof beam
Horizontal = 0.15m x 0.6m x 6.1m = 0.549m3 x 24kN/m3 = 13.18kN
Vertical = 0.15m x 0.6m x 5.277m = 0.47m3 x 24kN/m3 = 11.40kN
Total = 64.38 + 13.18 + 11.40 = 88.96/2 = 44.48kN (transfer to column)

2. Ground floor column = 0.3m x 0.3m x 3m = 0.27m3 x 24kN/m3 = 6.48kN


(The car porch is only at ground floor)

3. Ground floor
a) Slab layout
6100

5277

2638.5

823
2638.5

Ly/Lx = 6100/5277 = 1.16 < 2 (two way slab)


Thus, load is disturbed to both vertical and horizontal beam.
- Horizontal: Beam = 0.15m x 0.6m x 6.1m = 0.55m3 x 24kN/m3 = 13.18kN
Slab = x 2.6385m x (6.1m + 0.823m)
= 9.133m2 x 3kN/m2 = 27.40kN
-Vertical:

Beam = 0.15m x 0.6m x 5.277m = 0.475m3 x 24kN/m3 = 11.40kN


Slab = x 2.6385m x 5.277m
= 6.96m2 x 3kN/m2 = 20.88kN
There is no brick wall because there is a car porch.

b) Sum of vertical and horizontal beam


= 13.18 + 27.40 + 11.40 + 20.88 = 72.86/2
= 36.43kN
Total working load of point 2 = 44.48 + 6.48 + 36.43
= 87.39kN
Point 3 (Car porch, different point)
1. Roof part
Figure below is the plan view of the roof, unit is mm.
6100

5277

Point 3

a) Roof weight = 6.1m x 5.277m = 32.19m2 x 2kN/m2 = 64.38kN


b) Roof beam
Horizontal = 0.15m x 0.6m x 6.1m = 0.549m3 x 24kN/m3 = 13.18kN
Vertical = 0.15m x 0.6m x 5.277m = 0.47m3 x 24kN/m3 = 11.40kN
Total = 64.38 + 13.18 + 11.40 = 88.96/2 = 44.48kN (transfer to column)

2. Ground floor column = 0.3m x 0.3m x 3m = 0.27m3 x 24kN/m3 = 6.48kN


(The car porch is only at ground floor)

3. Ground floor
a) Slab layout
6100

5277

2638.5

823
2638.5

Ly/Lx = 6100/5277 = 1.16 < 2 (two way slab)


Thus, load is disturbed to both vertical and horizontal beam.
- Horizontal: Beam = 0.15m x 0.6m x 6.1m = 0.55m3 x 24kN/m3 = 13.18kN
Slab = x 2.6385m x (6.1m + 0.823m)
= 9.133m2 x 3kN/m2 = 27.40kN
-Vertical:

Beam = 0.15m x 0.6m x 5.277m = 0.475m3 x 24kN/m3 = 11.40kN


Slab = x 2.6385m x 5.277m
= 6.96m2 x 3kN/m2 = 20.88kN
There is no brick wall because there is a car porch.

b) Sum of vertical and horizontal beam


= 13.18 + 27.40 + 11.40 + 20.88 = 72.86/2= 36.43kN
Total working load of point 3 = 44.48 + 6.48 + 36.43
= 87.39kN (value is same with point 2 as it support the
same load of car porch, in a different location point.)

You might also like