CLIENT :

YAMUNANAGAR

INDIA

EQPT. :

Designed by: PZL

CHECK FOR CROSS OVER AREA AS PER CL. R-5.11 OF TEMA

INPUT DATA
No of tube passes
:
Thickness of floating head flange
T
Distance of weld of dish from outer face
h
Nominal thickness of dish
tn
Step on floating head flange
s1
Step on tubesheet
s2
Gasket thickness
tg
ID of flt head flange
ID
Crown radius of floating head dish
R
No. of tubes in first pass
n
Tube OD
do
Tube thk.
t
Distance z
z
CALCULATIONS
Distance b = sqrt( (ID/2)^2 - z^2)
b
Tube ID d = do-2*t
d
Distance x = T+tg-s1-s2-h-tn
x
Radius r = sqrt( R^2 - z^2)
r
H = SQRT(R^2-(ID/2)^2)
H
Distance a = r-h+x
a
X flow Area required (Ar) =1.3 *{ n * pi() * (d)^2 / 4}=
Area A1 =
b*x
=
-1
2
2
2
Area A2 =0.5*sin (b/r)*r -0.5*sqrt(r -b )*b
=
Total area avaliable(Aa) = A1 + A2
=

OK

FOUR
212 mm
45 mm
66 mm
8 mm
7 mm
6.35 mm
1515 mm
1250 mm
381
25.4 mm
2.5 mm
269.4 mm
707.98 mm
20.4 mm
92.35 mm
1220.62 mm
994.33 mm
318.64 mm
161889.45 mm2
65381.58 mm2
108958.48 mm2
174340.06 mm2