Professional Documents
Culture Documents
Catalogo RACO
Catalogo RACO
Catalogo RACO
A2
G E N E R A L I N F O R M AT I O N S T E E L B O X E S A N D C O V E R S
Applications: Steel Boxes
RACO high-quality steel boxes:
Are used in branch circuit wiring
to splice wires
Accommodate wiring devices,
such as switches and receptacles
Most may also serve as fixture
supports
Provide excellent protection
for wiring system or devices
Must be closed with a cover,
light fixture canopy or wallplate
Permit access to conductors
for maintenance
Allow for branch circuit runs
Provide two-hour fire rating for 4x4
or smaller wall opening
Product Features: Outlet Boxes
for Fixture or Fan Support
These high-quality boxes:
Are listed to support lighting fixture
canopies or fans
Feature oversized #10 screws
to provide strength and rigidity
Product Features:
Patented TKO Knockouts
TKO knockouts offer greater flexibility with RACO patented combination 1/2" and 3/4" knockout
Stock just one product instead
of two or three
One product for the installer
to carry
A3
Compliances
RACO steel boxes and covers generally carry the following compliance
ratings. Check specific catalog
pages for individual compliances.
UL Listed Standard 514-A,
file E195978 (QCIT Category)
Boxes are listed for their Electrical
Applications (electrical codes), UL
Green Book
Boxes are listed for mechanical
properties, including the Two-Hour
Fire Rating, (building codes) UL
Orange Book
CSA Certified C22.2 #18,
CSA File LR-1082
U.S. Federal Specification and
Standards W-J-800
ANSI/NEMA OS1
Federal Manufacturers number
28488
Reference Data
TKO knockout U.S. Patent
4,640,433; Canada Patent
1,260,597
Ceiling fan outlet box U.S.
Patent 4,892,211; Canada Patent
1,324,360; Mexico Patent 166,125
Far-side support (#978) U.S.
Patent 4,898,357
BOX-LOC U.S. Patent 5,408,045
MEXICO Patent 186848
Adjust-A-Brace U.S. Patent
5,330,137 and 5,927,667 U.S.
Steel Stud box Support (#978)
4,898,357 U.S.
W.P. self tap holes 4,898,453 U.S.
and 4,906,206 U.S.
G E N E R A L I N F O R M AT I O N S T E E L B O X E S A N D C O V E R S
A4
G E N E R A L I N F O R M AT I O N S TA N D A R D S , 1 9 9 9 N AT I O N A L E L E C T R I C A L C O D E S
Wiring Capacity: Steel Outlet
And Switch Boxes; Cubic Inches
Maximum Number of Conductors
or Minimum Size Box Required
National Electrical Code Article
370-16
The purpose of NEC Article 370-16
is to determine the maximum conductor count or the minimum box
size required for an application. It
also may be used to determine how
many other conductors may be
added without exceeding the Codeprescribed limit. Most applications
have determined the number of
conductors. The question that then
remains is the smallest (minimum)
size box that is permitted. The rules
of Article 370-16 are to be used to
determine the Code-recognized limit.
Selection of an outlet or junction box
for use in an electrical circuit work
must take into consideration the
maximum number of wires permitted
in the box. Safe electrical practice
demands that wires not be jammed
into boxes because of the possibility
of nicks, abrasions or other damage
to the insulating material, creating
the potential for ground faults or
short circuits.
A5
G E N E R A L I N F O R M AT I O N S TA N D A R D S , 1 9 9 9 N AT I O N A L E L E C T R I C A L C O D E S
A6
G E N E R A L I N F O R M AT I O N S TA N D A R D S , 1 9 9 9 N AT I O N A L E L E C T R I C A L C O D E S
MOST OFTEN REQUESTED ARTICLES OF THE 1999
NATIONAL ELECTRICAL CODE
A7
RACO STEEL BOXES
& COVERS
G E N E R A L I N F O R M AT I O N B O X S E L E C T I O N
42.0
30.3
29.5
21.5
21.0
18.0
16.5
4-11/16" Sq.
2-1/8" Deep
4" Sq.
2-1/8" Deep
4-11/16" Sq.
1-1/2" Deep
4" Sq.
2-1/8" Deep
4" Sq.
1-1/2" Deep
Switch
3-1/2" Deep
Handy
2-1/8" Deep
15.5
14.0
13.0
12.5
6.0
4" Oct.
1-1/2" Deep
Switch
2-3/4" Deep
Handy
1-7/8" Deep
Switch
2-1/2" Deep
CONDUIT
STEEL
BOXES
CU. IN.
CONDUIT
STEEL
BOXES
30.3
21.5
21.0
18.0
15.8
15.5
4" Sq.
2-1/8" Deep
4" Oct.
2-1/8"
4" Sq.
1-1/2" Deep
Switch
3-1/2" Deep
Switch
4" Oct.
2-9/64" Deep 1-1/2" Deep
14.0
12.5
4.0
CABLE
STEEL
BOXES
Switch
Switch
2-3/4" Deep 2-1/2" Deep
A8
G E N E R A L I N F O R M AT I O N B O X S E L E C T I O N
Calculate The Minimum Size Box
Part (1) of Section 370-16(a) of the
National Electrical Code describes
the detailed way of counting wires,
as well as clamps, fittings or devices
(i.e., switches, receptacles, combination devices) by establishing an
equivalent conductor value for each.
Those values are added together to
get a total number of conductors.
The minimum size box is the smallest
one in Table 370-16(a) that can
accommodate that number
of conductors.
1. No matter how many ground wires
come into a box, they only count
as one conductor within the box.
2. Any wire running unbroken through
the box counts as one wire.
3. Each wire coming into a splice
device (crimp or twist-on type) is
counted as one wire.
4
1
1
2
Total
B O X F I L L TA B L E
DEDUCTIONS
Volume
Required per
Conductor
Size per
Deductions
10
11
12
13
14
#18 (1.50)
9.00
10.50
12.00
13.50
15.00
16.50
18.00
19.50
21.00
#16 (1.75)
10.50
12.25
14.00
15.75
17.50
19.25
21.00
22.75
24.50
#14 (2.00)
12.00
14.00
16.00
18.00
20.00
22.00
24.00
26.00
28.00
#12 (2.25)
13.50
15.75
18.00
20.25
22.50
24.75
27.00
29.25
31.50
#10 (2.50)
15.00
17.50
20.00
22.50
25.00
27.50
30.00
32.50
35.00
#8 (3.00)
18.00
21.00
24.00
27.00
30.00
33.00
36.00
39.00
42.00
#6 (5.00)
30.00
35.00
40.00
45.00
50.00
55.00
60.00
65.00
70.00
A9
B R A C K E T T E C H N I C A L D ATA
BRACKET TYPE
FA
LENGTH
6-7/16"
1-61/64"
6-1/4"
5-1/2"
WIDTH
5/8"
2"
21/32"
2-1/4"
OFFSET
F O R M E TA L
FOR WOOD
FH
FM
LB
MS
7-3/8"
6-7/8"
2-3/8"
1-31/32"
4-1/2"
1-9/16"
1-9/16"
2-23/32"
3-3/64"
1-1/2"
3/8"
3/8"
1/4"
TS
7"
W
6-25/32"
1-1/16"
1-1/16"
17/64"
1-5/16"
A Bracket
B Bracket
D Bracket
FA Bracket
Positions
handy box
against face
and side of
stud. Very rigid.
Face mounts
on front edge
of wood stud.
Use when
space between
studs is limited.
Allows box to
be mounted on
either side of
stud.
Allows box
to be flush
mounted to
stud or joist.
FH Bracket
Side-mount
bracket with
hooks that
drive into face
of stud.
FM Bracket
Mounts on
flat side of
stud.
J Bracket
LB Bracket
Spurs, slotted
holes for toenailing. Gauging
notches at 3/8"
and 1/2".
Face mounts
on front edge
of wood stud.
Use when
space between
studs is limited.
5/8" offset to
clear narrow
door molding.
W Bracket
BOX-LOC MS
Bracket
Positions box
away from side
of stud to clear
the trim molding
of a door frame.
TS Bracket
Positions box
on either side
of stud.
C L A M P T E C H N I C A L D ATA A N D S T U D T Y P E
R A C E WAY T Y P E
CLAMP TYPE
A R M O R E D CA B L E ( B X )
STEEL
ALUMINUM
M E TA L C L A D CA B L E
INTERLOCKING (MCI)
STEEL
ALUMINUM
L T Y P E
N O N M E TA L L I C
S H E AT H E D CA B L E
FLEXIBLE CONDUIT
STEEL
ALUMINUM
# 1 4 - 2 t o # 1 0 - 3 w / gr o u n d
X TYPE
#14-2 (.444 in
outer diam.) to
largest size to
fit in clamp
#14-2 (.444 in
outer diam.) to
largest size to
fit in clamp
.425 to .600
outer diam.
.425 to .600
outer diam.
# 9 O R A O L T Y P E
#14-2 w/ground
BN TYPE
# 1 4 - 2 t o # 1 0 - 3 w / gr o u n d
Q TYPE
# 1 4 - 2 w / g r o u n d o r # 1 2 - 2 w / gr o u n d
L TYPE
X TYPE
#9 OR AOL TYPE
BN TYPE
PLASTER EARS
1/2"
CONDUIT
KO
3/4"
CONDUIT
KO
O TYPE
1"
CONDUIT
KO
7/8"
1-3/32"
TKO
CONDUIT CABLE PRIOUTS
Always in pairs.
KO
FLAT-BOTTOMED
CABLE PRIOUTS
Eliminate chance
of cable being cut.
ONE-SCREW EAR
TWO-SCREW EAR
G E N E R A L I N F O R M AT I O N B O X S E L E C T I O N
A10
C E I L I N G FA N S U P P O R T P R O D U C T S
Application
The RACO 7120 is a premium
box for rugged new work
or old work ceiling fan and
fixture installations
Product Features
The 7120 is made of heavy-duty
engineered polycarbonate
Rated for 70 pound ceiling fan
and fixture support
Self-gripping wire entry clamps
Grips the joist for hands free
positioning and installation
Positioning tabs provide
fast accurate mounting on
studs or joists
Positioning tabs can easily
be cut off in field for old
work installation
Designed to accommodate
1/2" thick sheetrock
Mounting hardware and
instructions included
Compliances
Standard 514-C,
File E104681 and R9320
SADDLE BOX
7120
O R D E R I N G I N F O R M AT I O N - D I M E N S I O N S
4" ROUND CEILING FAN AND FIXTURE BOX SADDLE BOX
F O R N O N M E TA L L I C S H E AT H E D C A B L E O R C O N D U I T 1 2 . 5 C U B I C I N C H E S
RECOMMENDED MAX.
CU.
UPC
C ATA L O G
CABLE
S T D.
S U P P O R T L OA D S
DESCRIPTION
KNOCKOUTS IN.
BAR
NUMBER
CLAMPS
PKG.
C E I L I N G FA N
FIXTURE
C A P.
CODE
( DY N A M I C ) L B S . ( S TAT I C ) L B S .
7120
2-1/2"
12.5 20*
* P a c k a g e d i n a s t a c k ab l e , i n d i v i d u a l c h i p b o a r d b o x s u i t ab l e f o r s h e l f d i s p l ay
SADDLE BOX
70
70
A11
C E I L I N G FA N S U P P O R T P R O D U C T S
1/2", 1-1/2" AND 2-1/8" DEEP
Application
Product Features
295-1, 295 include nonmetallic
sheathed cable connector,
mounting hardware, and
instructions
296-1
295
295-1
296
Compliance
File E195978
294-1
299
294
O R D E R I N G I N F O R M AT I O N - D I M E N S I O N S
4" ROUND CEILING FAN PAN - 1/2" DEEP DRAWN
WITH CONDUIT KOS 6.0 CUBIC INCHES
KNOCKOUTS
C ATA L O G
NUMBER DESCRIPTION
SIDES
CABLE
C O N D.
B OT T O M
C O N D.
M A X . RECOMMENDED
SUPPORT LOADS
STD. U P C
FIXTURE
PKG. BAR CEILING FAN
CODE (DYNAMIC)
(STATIC)
LBS.
LBS.
295-1
4-1/2"
10
295
4-1/2"
10*
35
75
35
75
* P a c k a g e d i n a s t a c k ab l e , i n d i v i d u a l c h i p b o a r d b o x s u i t ab l e f o r s h e l f d i s p l ay
4 " O C TA G O N C E I L I N G FA N B O X 1 - 1 / 2 " A N D 2 - 1 / 8 " D E E P D R AW N
W I T H N O N M E TA L L I C S H E AT H E D C A B L E C L A M P S
M A X . RECOMMENDED
KNOCKOUTS
BOX
SUPPORT LOADS
UPC
C ATA L O G B O X
STD.
VOLUME
SIDES
B OT T O M
BAR CEILING FAN
FIXTURE
N U M B E R D E P T H CU.
PKG.
CODE (DYNAMIC)
(STATIC)
IN.
C A B L E C O N D. C O N D.
LBS.
LBS.
296-1
1-1/2"
15.5
21/2"
1-1/2"
20
35
75
296
1-1/2"
15.5
21/2"
1-1/2"
8*
35
75
299
2-1/8"
21.5
2-1/2"
1-1/2"
6*
35
75
* P a c k a g e d i n a s t a c k ab l e , i n d i v i d u a l c h i p b o a r d b o x s u i t ab l e f o r s h e l f d i s p l ay
4 " O C TA G O N C E I L I N G FA N B O X 2 - 1 / 8 " D E E P D R AW N
W I T H N O N M E TA L L I C S H E AT H E D C A B L E C L A M P S 2 1 . 5 C U B I C I N C H E S
KNOCKOUTS
C ATA L O G D E S C R I P T I O N
NUMBER BRACKET &
SETBACK
SIDES
B OT T O M
CABLE
C O N D.
C O N D.
M A X . RECOMMENDED
SUPPORT LOADS
STD. U P C
FIXTURE
PKG. BAR CEILING FAN
CODE (DYNAMIC)
(STATIC)
LBS.
LBS.
294-1
FA brkt., 1/2"
2-1/2"
1-1/2"
10
294
FA brkt., 1/2"
2-1/2"
1-1/2"
10*
35
35
50
50
* P a c k a g e d i n a s t a c k ab l e , i n d i v i d u a l c h i p b o a r d b o x s u i t ab l e f o r s h e l f d i s p l ay
REPLACEMENT HARDWARE FAN MOUNTING SCREWS
C ATA L O G
NUMBER
DESCRIPTION
SHIP
C A R T O N Q T Y.
8994
# 1 0 - 3 2 x 1 - 3 / 8 " r e p l a c e m e n t s c r e w s fo r R A C O
catalog numbers 295, 295-1
INNER
PA C K Q T Y.
500*
50
300*
30
250*
25
8995
# 1 0 - 3 2 x 2 - 3 / 8 " r e p l a c e m e n t s c r e w s fo r R A C O
catalog numbers 296, 296-1
8996
# 1 0 - 3 2 x 3 - 1 / 2 " r e p l a c e m e n t s c r e w s fo r R A C O
catalog numbers 294, 294-1, 299
* S o l d i n s h i p c a r t o n q u a n t i t i e s o n ly. H u b b e l l R A C O d o e s n o t b r e a k c a r t o n q u a n t i t i e s o n t h e s e i t e m s
A12
C E I L I N G FA N S U P P O R T P R O D U C T S
NEW
NEW
Brace Applications
RETRO-BRACE is intended
for installations of heavy lighting
fixtures or ceiling paddle fans in
old work or new work applications
934, 935
RETRO-BRACE
923, 924
KWIK-BRACE
NEW
NEW
925-928
KWIK-BRACE
284
GORILLA-RING
O R D E R I N G I N F O R M AT I O N - D I M E N S I O N S
REMODELING BRACES FOR LIGHTING FIXTURES OR CEILING FANS RETRO-BRACE
W I T H B O X F O R N O N M E TA L L I C S H E AT H E D C A B L E C L A M P S
C ATA L O G
NUMBER
M A X . RECOMMENDED
SUPPORT LOADS
CEILING FAN
FIXTURE
(DYNAMIC)
(STATIC)
LBS.
LBS.
DESCRIPTION
CU. IN.
C A P.
S T D.
PKG.
UPC
BAR CODE
935
15.5
6*
35
50
934
21.5
6*
35
50
* P a c k a g e d i n a s t a c k ab l e , i n d i v i d u a l c h i p b o a r d b o x s u i t ab l e f o r s h e l f d i s p l ay
NEW CONSTRUCTION BRACES FOR LIGHTING FIXTURES OR CEILING FANS
K W I K - B R A C E W I T H B O X F O R N O N M E TA L L I C S H E AT H E D C A B L E C L A M P S
MAX. RECOMMENDED
CU.
SUPPORT LOADS
S T D.
UPC
C ATA L O G
D E S C R I P T I O N IN.
NUMBER
PKG.
BAR CODE
CEILING FAN
FIXTURE
CAP.
(DYNAMIC) LBS.
(STATIC) LBS.
923
6.0
18
35
75
924
6.0
6*
35
75
925
15.5
12
35
75
926
15.5
6*
35
75
927
21.5
12
35
75
928
21.5
6*
35
75
* P a c k a g e d i n a s t a c k ab l e , i n d i v i d u a l c h i p b o a r d b o x s u i t ab l e f o r s h e l f d i s p l ay
CONCRETE RING - 4" DEEP FOR CEILING FAN SUPPORT GORILLA RING
C ATA L O G
NUMBER
284
Compliance
File E195978
DESCRIPTION
RACO 890 or
892 cover must be
ordered separately
KNOCKOUTS
MAX. RECOMMENDED
SUPPORT LOADS
SIDES
B OT T O M C U .
UPC
S T D.
IN.
B A R CEILING FAN
FIXTURE
PKG.
C A B L E C O N D. C O N D. C A P.
C O D E (DYNAMIC)
(STATIC)
LBS.
LBS.
Double
row
1/2" &
3/4"
49.3
35
75
DESCRIPTION
SHIP
C A R T O N Q T Y.
INNER
PA C K Q T Y.
8994
# 1 0 - 3 2 x 1 - 3 / 8 " r e p l a c e m e n t s c r e w s fo r R A C O
catalog numbers 923, 924
500*
50
8995
# 1 0 - 3 2 x 2 - 3 / 8 " r e p l a c e m e n t s c r e w s fo r R A C O
catalog numbers 925, 926, 935
300*
30
8996
# 1 0 - 3 2 x 3 - 1 / 2 " r e p l a c e m e n t s c r e w s fo r R A C O
catalog numbers 927, 928, 934
250*
25
* S o l d i n s h i p c a r t o n q u a n t i t i e s o n ly. H u b b e l l R A C O d o e s n o t b r e a k c a r t o n q u a n t i t i e s o n t h e s e i t e m s
A13
C E I L I N G PA N S
1/2" AND 3/4" DEEP 3-1/2" ROUND
Application
RACO STEEL BOXES
& COVERS
File E195978
703
287
292, 8292
O R D E R I N G I N F O R M AT I O N - D I M E N S I O N S
1-1/2"
50
8292
1-1/2"
50
No
50
No
50
1-1/2"
50
No
50
DESCRIPTION
S T D.
PKG.
703
8703-5
100
50*
UPC
BAR CODE
*5 Bundles of 10
3-1/2" ROUND PAN
DIMENSIONS
C ATA L O G N U M B E R
292, 8292
9/16"
3-3/8"
287
3/4"
3-3/8"
A14
C E I L I N G PA N S
1/2" DEEP 4" ROUND
Applications
Ceiling pans are used in the
installation of ceiling or wall
lighting fixtures
RACO 293 and 8293 are not
designed for ceiling fan support
Product Features
295-1, 295 include nonmetallic
sheathed cable connector, mounting
hardware, and instructions
Lock-washers on 295, 295-1
prevent the high-strength, hardened
screws from loosening from vibration
293, 8293
295-1
295
Compliance
File E195978
O R D E R I N G I N F O R M AT I O N - D I M E N S I O N S
4" ROUND CEILING FAN AND FIXTURE PAN 1/2" DEEP DRAWN
WITH CONDUIT KOS 6.0 CUBIC INCHES
KNOCKOUTS
C ATA L O G
NUMBER DESCRIPTION
SIDES
B OT T O M
C O N D.
C O N D.
M A X . RECOMMENDED
SUPPORT LOADS
S T D. U P C
CEILING FAN
FIXTURE
PKG. BAR
C O D E (DYNAMIC)
(STATIC)
LBS.
LBS.
293
5-1/2"
50
8293
5-1/2"
50
295-1
4-1/2"
10
295
4-1/2"
10*
No
50
No
50
35
75
35
75
* P a c k a g e d i n a s t a c k ab l e , i n d i v i d u a l c h i p b o a r d b o x s u i t ab l e f o r s h e l f d i s p l ay
4" ROUND PAN
DIMENSIONS
C ATA L O G
NUMBER
293, 8293
4"
9/16"
295, 295-1
4"
9/16"
A15
O C TA G O N B O X E S
1-1/2" DEEP
Applications
RACO STEEL BOXES
& COVERS
File E195978
112
110
119
111
O R D E R I N G I N F O R M AT I O N - D I M E N S I O N S
3 - 1 / 2 " O C TA G O N B O X 1 - 1 / 2 " D E E P D R AW N
WITH CONDUIT KOS 11.8 CUBIC INCHES
KNOCKOUTS
DESCRIPTION
C ATA L O G B R A C K E T &
SIDES
B OT T O M
N U M B E R SETBACK
C O N D.
C O N D.
110
4-1/2"
M A X . RECOMMENDED
UPC
S UPPORT LOADS
S T D. B A R CEILING FAN
FIXTURE
P K G . C O D E (DYNAMIC)
(STATIC)
LBS.
LBS.
1-1/2"
50
No
50
3 - 1 / 2 " O C TA G O N B O X 1 - 1 / 2 " D E E P D R AW N
W I T H N O N M E TA L L I C S H E AT H E D C A B L E C L A M P S 1 1 . 8 C U B I C I N C H E S
KNOCKOUTS
M A X . RECOMMENDED
DESCRIPTION
SIDES
B OT T O M
UPC
S UPPORT LOADS
C ATA L O G B R A C K E T &
S T D. B A R
CEILING FAN
FIXTURE
N U M B E R SETBACK
P K G . C O D E (DYNAMIC)
C A B L E C O N D.
C O N D.
(STATIC)
LBS.
LBS.
112
2-1/2"
1-1/2"
50
No
50
119
TS brkt., 1/2"
1-1/2"
1-1/2"
25
No
50
3 - 1 / 2 " O C TA G O N E X T E N S I O N R I N G 1 - 1 / 2 " D E E P D R AW N
WITH CONDUIT KOS 11.8 CUBIC INCHES
C ATA L O G
NUMBER
111
3-1/2" OCTAGON BOXES
4"
3/
2-
DESCRIPTION
BRACKET &
SETBACK
Extension ring
KNOCKOUTS
SIDES
C O N D.
B OT T O M
C O N D.
4-1/2"
UPC
BAR
CODE
S T D.
PKG.
25
DIMENSIONS
C ATA L O G
NUMBER
110
3-7/16"
1-9/16"
112
3-7/16"
1-9/16"
119
3-7/16"
1-9/16"
7-5/32"
1/2"
1-1/4"
111
3-7/16"
1-9/16"
A16
O C TA G O N B O X E S
1-1/2" DEEP
Application
Octagon boxes are used in
the installation of ceiling or wall
lighting fixtures
Product Features
Combination screw heads provide
for faster installation
126
125, 8125
127, 8127
161
158
O R D E R I N G I N F O R M AT I O N - D I M E N S I O N S
Compliance
File E195978
4 " O C TA G O N B O X 1 - 1 / 2 " D E E P D R AW N
WITH CONDUIT KOS 15.5 CUBIC INCHES
C ATA L O G
NUMBER
4" OCTAGON
DESCRIPTION
BRACKET &
SETBACK
KNOCKOUTS
SIDES
B OT T O M
C O N D.
C O N D.
S T D.
PKG.
UPC
BAR
CODE
125
4-1/2"
5-1/2"
50
8125
4-1/2"
5-1/2"
50
50
126
4-3/4"
3-1/2"
2-3/4"
127
2-1/2"
2-3/4"
3-1/2",
2-3/4"
50
3-1/2",
2-3/4"
M A X . RECOMMENDED
SUPPORT LOADS
CEILING FAN
FIXTURE
(DYNAMIC)
(STATIC)
LBS.
LBS.
No
50
No
50
No
50
No
50
8127
2-1/2"
2-3/4"
50
No
50
158
4 1/2"
5-1/2"
50
No
50
161
TS brkt., 1/2"
3-1/2"
5-1/2"
50
No
50
DIMENSIONS
C ATA L O G
NUMBER
125, 8125
4"
1-9/16"
126
4"
1-9/16"
127, 8127
4"
1-9/16"
158
4"
1-9/16"
1/2"
3-1/8"
161
4"
1-9/16"
7-5/32"
1/2"
1-1/4"
A17
O C TA G O N B O X E S
1-1/2" DEEP
Applications
128, 8128
324
130
146, 8146
Product Features
RACO offers a variety of labor
saving mounting brackets that
allow for easy positioning of box
along studs or joists
See Box Selection section in the
front of this catalog for complete
description of bracket types and
features
Fixture bar hanger allows box to
be located anywhere along length
of bar
RACO 324 includes a 3/8"
trade sized stud to accommodate
fixture stem
Combination screw heads provide
for faster installation
Compliances
164, 8164
160, 8160
O R D E R I N G I N F O R M AT I O N - D I M E N S I O N S
4 " O C TA G O N E X T E N S I O N R I N G S 1 - 1 / 2 " D E E P D R AW N
WITH CONDUIT KOS 15.5 CUBIC INCHES
DESCRIPTION
BRACKET &
SETBACK
C ATA L O G
NUMBER
SIDES
C O N D.
KNOCKOUTS
B OT T O M
C O N D.
S T D.
PKG.
UPC
BAR
CODE
128
Extension ring
4-1/2"
50
8128
Extension ring
4-1/2"
25
130
Extension ring
2-1/2", 2-3/4"
50
4 " O C TA G O N W I T H B A R H A N G E R 1 - 1 / 2 " D E E P D R AW N
WITH CONDUIT KOS 15.5 CUBIC INCHES
KNOCKOUTS
File E195978
150
145
C ATA L O G
NUMBER
DESCRIPTION
BRACKET &
SETBACK
324
SIDES
C O N D.
4-1/2"
B OT T O M
C O N D.
4-1/2"
M A X . RECOMMENDED
UPC
SUPPORT LOADS
S T D. B A R CEILING FAN
FIXTURE
P K G . C O D E (DYNAMIC)
(STATIC)
LBS.
LBS.
25
No
10*
4 " O C TA G O N B O X 1 - 1 / 2 " D E E P D R AW N
W I T H N O N M E TA L L I C S H E AT H E D C A B L E C L A M P S 1 5 . 5 C U B I C I N C H E S
KNOCKOUTS
DESCRIPTION
SIDES
B OT T O M
C ATA L O G B R A C K E T &
N U M B E R SETBACK
C A B L E C O N D.
C O N D.
M A X . RECOMMENDED
UPC
SUPPORT LOADS
S T D. B A R CEILING FAN
FIXTURE
P K G . C O D E (DYNAMIC)
(STATIC)
LBS.
LBS.
146
2-1/2"
1-1/2"
50
8146
2-1/2"
1-1/2"
50
145
Side holes,
1/8" & 1/4"
2-1/2"
1-1/2"
50
150
Ears
2-1/2"
1-1/2"
50
160
J brkt., 3/8"
or 1/2"
2-1/2"
1-1/2"
50
8160
J brkt., 3/8"
or 1/2"
2-1/2"
1-1/2"
50
164
TS brkt., 1/2"
1-1/2"
1-1/2"
50
8164
TS brkt., 1/2"
1-1/2"
1-1/2"
50
No
50
No
50
No
50
No
50
No
50
No
50
No
50
No
50
DIMENSIONS
C ATA L O G
NUMBER
146, 8146
4"
1-9/16"
145
4"
1-9/16"
150
4"
1-9/16"
160, 8160
4"
1-9/16"
1/2"
3-1/8"
164, 8164
4"
1-9/16"
7-5/32"
1/2"
1-1/4"
A18
O C TA G O N B O X E S
1-1/2" DEEP
296
296-1
326, 8326
153
157
155
O R D E R I N G I N F O R M AT I O N - D I M E N S I O N S
4 " O C TA G O N C E I L I N G FA N A N D F I X T U R E B O X 1 - 1 / 2 " D E E P D R AW N
W I T H N O N M E TA L L I C S H E AT H E D C A B L E C L A M P S 1 5 . 5 C U B I C I N C H E S
File E195978
31/
2"
Application
DESCRIPTION
BRACKET &
SETBACK
C ATA L O G
NUMBER
KNOCKOUTS
SIDES
B OT T O M
C A B L E C O N D.
C O N D.
M A X . RECOMMENDED
SUPPORT LOADS
S T D. U P C
FIXTURE
PKG. B A R CEILING FAN
C O D E (DYNAMIC)
(STATIC)
LBS.
LBS.
296-1
2-1/2"
1-1/2"
20
296
2-1/2"
1-1/2"
8*
35
75
35
75
* P a c k a g e d i n a s t a c k ab l e , c h i p b o a r d b o x s u i t ab l e f o r s h e l f d i s p l ay
4 " O C TA G O N W I T H B A R H A N G E R 1 - 1 / 2 " D E E P D R AW N
W I T H N O N M E TA L L I C S H E AT H E D C A B L E C L A M P S 1 5 . 5 C U B I C I N C H E S
KNOCKOUTS
DESCRIPTION
SIDES
B OT T O M
BRACKET &
SETBACK
C A B L E C O N D.
C O N D.
C ATA L O G
NUMBER
M A X . RECOMMENDED
UPC
SUPPORT LOADS
S T D. B A R
CEILING FAN
FIXTURE
PKG. C O D E (DYNAMIC)
(STATIC)
LBS.
LBS.
326
2-1/2"
25
8326
2-1/2"
25
No
10*
No
10*
C ATA L O G
NUMBER
KNOCKOUT
DESCRIPTION
SIDES
B OT T O M
BRACKET &
SETBACK
C A B L E C O N D.
C O N D.
UPC
S T D. B A R
PKG. C O D E
M A X . RECOMMENDED
SUPPORT LOADS
CEILING FAN
FIXTURE
(DYNAMIC)
(STATIC)
LBS.
LBS.
No
50
153
2-1/2"
1-1/2"
25
155
TS brkt., 1/2"
1-1/2"
1-1/2"
50
No
50
157
J brkt., 3/8"
or 1/2"
2-1/2"
1-1/2"
50
No
50
DIMENSIONS
C ATA L O G
NUMBER
296, 296-1
4"
1-9/16"
153
4"
1-9/16"
155
4"
1-9/16"
7-5/32"
1/2"
1-1/4"
157
4"
1-9/16"
1/2"
3-1/8"
A19
O C TA G O N B O X E S
1-1/2" AND 2-1/8" DEEP
Application
RACO STEEL BOXES
& COVERS
165
325, 8325
299
167
166
File E195978
O R D E R I N G I N F O R M AT I O N - D I M E N S I O N S
4 " O C TA G O N B O X W I T H B A R H A N G E R 1 - 1 / 2 " D E E P D R AW N
W I T H A R M O R E D C A B L E / M E TA L C L A D / F L E X C L A M P S 1 5 . 5 C U B I C I N C H E S
DESCRIPTION
C ATA L O G B R A C K E T &
NUMBER SETBACK
KNOCKOUTS
SIDES
B OT T O M
CABLE
C O N D.
C O N D.
M A X . RECOMMENDED
UPC
SUPPORT LOADS
S T D. B A R CEILING FAN
FIXTURE
P K G . CODE (DYNAMIC)
(STATIC)
LBS.
LBS.
325
2-1/2"
25
8325
2-1/2"
25
No
10*
No
10*
C ATA L O G
NUMBER
DESCRIPTION
BRACKET &
SETBACK
165
KNOCKOUTS
SIDES
B OT T O M
UPC
BAR
CODE
M A X . RECOMMENDED
SUPPORT LOADS
CEILING FAN
FIXTURE
(DYNAMIC)
(STATIC)
LBS.
LBS.
C O N D.
C O N D.
S T D.
PKG.
4-1/2"
5-1/2"
50
No
50
50
No
50
50
No
50
166
4-3/4"
3-1/2"
2-3/4"
167
2-1/2",
2-3/4"
2-3/4"
3-1/2"
4 " O C TA G O N B O X 2 - 1 / 8 " D E E P D R AW N
W I T H N O N M E TA L L I C S H E AT H E D C A B L E C L A M P S 2 1 . 5 C U B I C I N C H E S
DESCRIPTION
C ATA L O G B R A C K E T &
NUMBER SETBACK
299
KNOCKOUTS
SIDES
B OT T O M
C O N D.
4"
CABLE
C O N D.
2-1/2"
1-1/2"
M A X . RECOMMENDED
UPC
SUPPORT LOADS
S T D. B A R CEILING FAN
FIXTURE
P K G . CODE (DYNAMIC)
(STATIC)
LBS.
LBS.
50
No
50
* P a c k a g e d i n a s t a c k ab l e , i n d i v i d u a l c h i p b o a r d b o x s u i t ab l e f o r s h e l f d i s p l ay
DIMENSIONS
C ATA L O G
NUMBER
165
4"
2-1/8"
166
4"
2-1/8"
167
4"
2-1/8"
299
4"
2-1/8"
A20
O C TA G O N B O X E S
2-1/8" DEEP
175
177
294-1
176
294
O R D E R I N G I N F O R M AT I O N - D I M E N S I O N S
4 " O C TA G O N B O X 2 - 1 / 8 " D E E P D R AW N
W I T H N O N M E TA L L I C S H E AT H E D C A B L E C L A M P S 2 1 . 5 C U B I C I N C H E S
DESCRIPTION
C ATA L O G B R A C K E T &
NUMBER SETBACK
KNOCKOUTS
SIDES
B OT T O M
C A B L E C O N D. C O N D.
UPC
S T D. B A R
P K G . CODE
File E195978
175
2-1/2"
1-1/2"
50
177
TS brkt., 1/2"
1-1/2"
1-1/2"
25
176
J brkt., 5/8"
2-1/2"
1-1/2"
25
M A X . RECOMMENDED
SUPPORT LOADS
CEILING FAN
FIXTURE
(DYNAMIC)
(STATIC)
LBS.
LBS.
No
50
No
No
50
50
4 " O C TA G O N C E I L I N G FA N A N D F I X T U R E B O X 2 - 1 / 8 " D E E P D R AW N
W I T H N O N M E TA L L I C S H E AT H E D C A B L E C L A M P S 2 1 . 5 C U B I C I N C H E S
M A X . RECOMMENDED
KNOCKOUTS
SUPPORT LOADS
C ATA L O G D E S C R I P T I O N
S T D. U P C
B
R
A
C
K
E
T
&
S
I
D
E
S
B
A
R
CEILING FAN
FIXTURE
NUMBER
B OT T O M
PKG.
SETBACK
CODE (DYNAMIC)
(STATIC)
C A B L E C O N D. C O N D.
LBS.
LBS.
294-1
FA brkt., 1/2"
2-1/2"
1-1/2"
10
294
FA brkt., 1/2"
2-1/2"
1-1/2"
10*
35
75
35
75
* P a c k a g e d i n a s t a c k ab l e , c h i p b o a r d b o x s u i t ab l e f o r s h e l f d i s p l ay
4" OCTAGON BOXES
DIMENSIONS
1/
2"
C ATA L O G
NUMBER
3-
Application
175
4"
2-1/8"
177
4"
2-1/8"
7-5/32"
1/2"
1-1/4"
176
4"
2-1/8"
1/2"
3-1/8"
294, 294-1
4"
2-1/8"
5-1/2"
1/2"
2-1/4"
A21
O C TA G O N A N D R O U N D C O V E R S
Applications
729
5652-1
5653-1
731, 8731-5
5654-1
File E195978
O R D E R I N G I N F O R M AT I O N - D I M E N S I O N S
4 " O C TA G O N A N D R O U N D C O V E R S
C ATA L O G
NUMBER
DESCRIPTION
C U . S T D.
IN. PKG.
UPC
BAR
CODE
MAX. RECOMMENDED
S U P P O R T L OA D S
CEILING FAN
FIXTURE
(DYNAMIC)
(STATIC)
LBS.
LBS.
722
Flat, blank
100
8722
Flat, blank
100
8722-5
Flat, blank
724
F l a t , 1/ 2 " K O
100
8724
F l a t , 1/ 2 " K O
100
No
No
8724-5
F l a t , 1/ 2 " K O
50*
No
No
729
50
No
No
731
50
No
No
8731-5
50*
No
No
737
R a i s e d 1/ 2 ", o p e n , e a r s 2 - 3 / 4 " O . C .
3.0
50
No
50
727
R a i s e d 5 / 8", o p e n , e a r s 2 - 3 / 4 " O . C .
3.8
100
No
50
732
R a i s e d 1", o p e n , e a r s 2 - 3 / 4 " O . C .
6.5
25
No
50
50*
No
No
No
No
No
No
No
No
*5 Bundles of 10
5 " R O U N D S T E E L C L O S U R E P L AT E S
C ATA L O G
NUMBER
COLOR
DESCRIPTION
PKG.
TYPE
S T D.
PKG.
5652-1
Off-white
Shrink
10
5653-1
Off-white
Shrink
10
Off-white
Shrink
10
5654-1
UPC
BAR CODE
A22
Applications
Boxes are installed in ceilings
or walls for lighting fixtures,
switches or receptacles
Square boxes are used where
multiple conductor runs are split
into two or more directions to
bring power to a number of
electrical devices
185
191, 8191
190, 8190
192, 8192
O R D E R I N G I N F O R M AT I O N - D I M E N S I O N S
185
File E195978
5-1/2"
S T D.
PKG.
UPC
BAR
CODE
190
1 2 - 1/ 2 "
5-1/2"
50
8190
1 2 - 1/ 2 "
5 - 1/ 2 "
50
191
8 - 3/ 4 "
1 - 1/ 2 ", 4 - 3 / 4 "
50
8191
192
8192
8 - 1/ 2 "
4 - 3/ 4 "
8-1/2"
4-TKO
250V
189
250V
8189
181
8-3/4"
25
3 - 1/ 2 ", 2 - 3 / 4 "
50
50
3-1/2", 2-TKO
S T D.
PKG.
UPC
BAR
CODE
50
50
1-1/2", 4-3/4"
UPC
BAR
CODE
50
250V
10-1/2"
S T D.
PKG.
Compliances
204
181
189, 8189
50
DEEP DRAWN
CU.
IN.
S T D.
PKG.
UPC
BAR
CODE
21
50
DIMENSIONS
C ATA L O G
NUMBER
185
1-1/2"
190, 8190
1-1/2"
191, 8191
1-1/2"
192, 8192
1-1/2"
189, 8189
1-1/2"
181
1-1/2"
204
1-1/2"
A23
Applications
RACO STEEL BOXES
& COVERS
193
208, 8208
197,
8197
Product Features
RACO offers a variety of labor
saving mounting brackets that
allow for easy positioning of box
along studs or joists
196, 8196
199
227 BOX-LOC
O R D E R I N G I N F O R M AT I O N - D I M E N S I O N S
4" SQUARE BRACKETED BOXES 1-1/2" DEEP WELDED
WITH CONDUIT KOS 21.0 CUBIC INCHES
C ATA L O G
NUMBER
DESCRIPTION
BRACKET &
SETBACK
KNOCKOUTS
SIDES
B OT T O M
C O N D.
C O N D.
S T D.
PKG.
UPC
BAR
CODE
250V
197
FH, flush
6 - 1/ 2 ", 3 T K O 3 - 1/ 2 ", 2 T K O
25
250V
8197
FH, flush
6 - 1/ 2 ", 3 T K O 3 - 1/ 2 ", 2 T K O
25
250V
208
W, f l u s h
6 - 1/ 2 ", 3 T K O 3 - 1/ 2 ", 2 T K O
25
250V
8208
W, f l u s h
6 - 1/ 2 ", 3 T K O 3 - 1/ 2 ", 2 T K O
25
250V
193
B, flush
6 - 1/ 2 ", 4 T K O 3 - 1/ 2 ", 2 T K O
25
250V
196
FM, flush
6 - 1/ 2 ", 3 T K O 3 - 1/ 2 ", 2 T K O
25
250V
8196
FM, flush
6 - 1/ 2 ", 3 T K O 3 - 1/ 2 ", 2 T K O
25
199
FM, flush
6 - 3/ 4 "
25
227
BOX-LOC (MS)
6 - 1/ 2 ", 3 T K O 3 - 1/ 2 ", 2 T K O
flush
250V
1 - 1/ 2 ", 4 - 3/ 4 "
25
DIMENSIONS
C ATA L O G
NUMBER
Compliances
197, 8197
1-1/2"
7-3/8"
4-3/8"
208, 8208
1-1/2"
6-13/16"
5-15/16"
193
1-1/2"
2"
6"
196, 8196
1-1/2"
6-7/8"
4-3/8"
199
1-1/2"
6-7/8"
4-3/8"
227
1-1/2"
4-5/8"
5-1/2"
File E195978
A24
Applications
Boxes are installed in ceilings
or walls for lighting fixtures,
switches or receptacles
Square boxes are used where
multiple conductor runs are split
into two or more directions to
bring power to a number of
electrical devices
224
219
213
Product Features
RACO offers a variety of labor
saving mounting brackets that
allow for easy positioning of box
along studs or joists
218, 8218
229 BOX-LOC
O R D E R I N G I N F O R M AT I O N - D I M E N S I O N S
4" SQUARE 1-1/2" DEEP WELDED
W I T H A R M O R E D C A B L E / M E TA L C L A D / F L E X C L A M P S 2 1 . 0 C U B I C I N C H E S
C ATA L O G
NUMBER
250V
250V
250V
213
219
224
DESCRIPTION
KNOCKOUTS
BRACKET &
SIDES
B OT T O M
SETBACK
C A B L E C O N D.
C O N D.
4 - 1/ 2 ",
4
1 - 1/ 2 "
2 TKO
FH, flush
B, flush
S T D.
PKG.
UPC
BAR
CODE
50
2 - 1/ 2 ",
1 TKO
1 - 1/ 2 "
25
2 - 1/ 2 ",
1 TKO
1 - 1/ 2 "
25
1 - 1/ 2 "
25
250V
218
FM, flush
2 - 1/ 2 ",
1 TKO
250V
8218
FM, flush
2 - 1/ 2 ",
1 TKO
1 - 1/ 2 "
25
229
BOX-LOC
(MS) flush
2 - 1/ 2 ",
1 TKO
1 - 1/ 2 "
25
250V
DIMENSIONS
C ATA L O G
NUMBER
213
1-1/2"
Compliances
218
1-1/2"
6-7/8"
4-3/8"
219
1-1/2"
7-3/8"
4-3/8"
224
1-1/2"
2"
6"
229
1-1/2"
4-5/8"
5-1/2"
File E195978
A25
Applications
211, 8211
220, 8220
225
Product Features
RACO offers a variety of labor
saving mounting brackets that
allow for easy positioning of box
along studs or joists
223
File E195978
228 BOX-LOC
O R D E R I N G I N F O R M AT I O N - D I M E N S I O N S
250V
250V
4
1 - 1/ 2 "
50
2 TKO
8211
4 - 1/ 2 ",
2 TKO
1 - 1/ 2 "
50
1 - 1/ 2 "
25
250V
220
FH, flush
2 - 1/ 2 ",
1 TKO
250V
8220
FH, flush
2 - 1/ 2 ",
1 TKO
1 - 1/ 2 "
25
2 - 1/ 2 ",
1 TKO
1 - 1/ 2 "
25
2 - 1/ 2 ",
1 TKO
1 - 1/ 2 "
25
2 - 1/ 2 ",
1 TKO
1 - 1/ 2 "
25
250V
250V
225
223
B, flush
FM, flush
250V
228
BOX-LOC
(MS) flush
UPC
BAR
CODE
DIMENSIONS
C ATA L O G
NUMBER
211, 8211
1-1/2"
220, 8220
1-1/2"
7-3/8"
4-3/8"
225
1-1/2"
2"
6"
223
1-1/2"
6-7/8"
4-3/8"
228
1-1/2"
4-5/8"
5-1/2"
A26
Applications
Boxes are installed in ceilings
or walls for lighting fixtures,
switches or receptacles
Square boxes are used where
multiple conductor runs are split
into two or more directions to
bring power to a number of
electrical devices
244
232, 8232
233, 8233
231, 8231
NEW
Product Features
NEW
235, 8235
1/2" & 3/4" TKO
237
236
238
BOX-LOC
O R D E R I N G I N F O R M AT I O N - D I M E N S I O N S
4" SQUARE 2-1/8" DEEP WELDED
WITH CONDUIT KOS 30.3 CUBIC INCHES
C ATA L O G
NUMBER
DESCRIPTION
BRACKET &
SETBACK
KNOCKOUTS
SIDES
B OT T O M
C O N D.
C O N D.
S T D.
PKG.
UPC
BAR
CODE
250V
232
8 - 1/ 2 ", 4 - T K O 3 - 1/ 2 ", 2 - T K O
25
250V
8232
8 - 1/ 2 ", 4 - T K O 3 - 1/ 2 ", 2 - T K O
25
231
8 -3/ 4 "
1 - 1/ 2 ", 4 - 3/ 4 "
25
8231
8 -3/ 4 "
1 - 1/ 2 ", 4 - 3/ 4 "
25
233
8-1"
3 - 1/ 2 ", 2 - 3/ 4 "
25
8233
8-1"
3 - 1/ 2 ", 2 - 3/ 4 "
25
250V
235
TS, flush
6 - 1/ 2 ", 3 - T K O 3 - 1/ 2 ", 2 - T K O
25
250V
8235
TS, flush
6 - 1/ 2 ", 3 - T K O 3 - 1/ 2 ", 2 - T K O
25
236
FM, flush
6 - 3/ 4 "
25
250V
237
FM, flush
8 - 1/ 2 ", 4 - T K O 3 - 1/ 2 ", 2 - T K O
238
BOX-LOC
(MS) flush
250V
1 - 1/ 2 ", 4 - 3/ 4 "
8 - 1/ 2 ", 4 - T K O
3 - 1/ 2 ", 2 - T K O
25
25
C ATA L O G
NUMBER
Compliances
File E195978
250V
KNOCKOUTS
DESCRIPTION
BRACKET &
SETBACK
244
SIDES
C O N D.
8-1/2, 4-TKO
S T D.
PKG.
B OT T O M
C O N D.
2-1/2, 2-3/4"
UPC
BAR
CODE
25
DIMENSIONS
C ATA L O G
NUMBER
232, 8232
2-1/8"
231, 8231
2-1/8"
233, 8233
2-1/8"
235, 8235
2-1/8"
7-5/32"
4-5/16"
236
2-1/8"
7-5/8"
4-3/8"
238
2-1/8"
4-5/8"
5-1/2"
244
2-1/8"
A27
Applications
RACO STEEL BOXES
& COVERS
226
239
762
O R D E R I N G I N F O R M AT I O N - D I M E N S I O N S
File E195978
4" SQUARE PLENUM BOXES & COVER 1-1/2" & 2-1/8" DEEP DRAWN
WITH CONDUIT KOS
C ATA L O G
NUMBER
DESCRIPTION
BRACKET &
SETBACK
KNOCKOUTS
B OT T O M
1 - 1/ 2 " D e e p
8 - 1/ 2 "
4 - 3/ 4 "
3 - 1/ 2 "
2 - 3/ 4 "
21.0
50
239
2 - 1/ 8 " D e e p
8 - 1/ 2 "
4 - 3/ 4 "
3 - 1/ 2 "
2 - 3/ 4 "
30.3
25
762
G a s k e t e d c o v e r fo r
4" square boxes
50
226
SIDES
S T D.
PKG.
UPC
BAR
CODE
CU.
IN.
226
1-1/2"
239
2-1/8"
A28
Applications
Boxes are installed in ceilings or
walls for lighting fixtures, switches
or receptacles
Square boxes are used where
multiple conductor runs are split
into two or more directions to
bring power to a number of
electrical devices
240, 8240
242
241, 8241
NEW
Product Features
RACO offers a variety of labor
saving mounting brackets that
allow for easy positioning of box
along studs or joists
243
BOX-LOC
248
O R D E R I N G I N F O R M AT I O N - D I M E N S I O N S
242
DESCRIPTION
KNOCKOUTS
BRACKET &
SIDES
B OT T O M
SETBACK
C A B L E C O N D.
C O N D.
4 - 1/ 2 ",
4
1 - 1/ 2 "
2 TKO
250V
240
TS, flush
2 - 1/ 2 ",
1 TKO
250V
8240
TS, flush
2 - 1/ 2 ",
1 TKO
S T D.
PKG.
UPC
BAR
CODE
25
1 - 1/ 2 "
25
1 - 1/ 2 "
25
C ATA L O G
NUMBER
File E195978
250V
241
DESCRIPTION
KNOCKOUTS
BRACKET &
SIDES
B OT T O M
SETBACK
C A B L E C O N D.
C O N D.
2 - 1/ 2 ",
TS, flush
4
1 - 1/ 2 "
1 TKO
UPC
BAR
CODE
25
8241
TS, flush
2 - 1/ 2 ",
1 TKO
1 - 1/ 2 "
25
250V
243
BOX-LOC
(M S ) f l u s h
2 - 1/ 2 ",
1 TKO
1 - 1/ 2 "
25
250V
248
4 - 1/ 2 ",
2 TKO
1 - 1/ 2 "
25
250V
DIMENSIONS
C ATA L O G
NUMBER
2-1/8"
240, 8240
2-1/8"
7-7/32"
4-5/16"
241, 8241
2-1/8"
7-5/32"
4-5/16"
243
2-1/8"
4-5/8"
5-1/2"
248
2-1/8"
242
250V
S T D.
PKG.
A29
Applications
RACO STEEL BOXES
& COVERS
752, 8752,
8752-5
756-759, 767,
8756, 8767
753, 8753,
8753-5
Compliances
File E195978
File LR-1082
787, 8787
772
785-786
O R D E R I N G I N F O R M AT I O N - D I M E N S I O N S
C ATA L O G
NUMBER
DESCRIPTION
CU.
IN.
S T D.
PKG.
752
Flat, blank
50
8752
Flat, blank
50
8752-5
Flat, blank
50*
753
F l a t , 1/ 2 " K O i n c e n t e r
50
8753
F l a t , 1/ 2 " K O i n c e n t e r
50
8753-5
F l a t , 1/ 2 " K O i n c e n t e r
50*
767
R a i s e d 1/ 2 ", o p e n , e a r s 2 - 3 / 4 " O . C .
3.0
25
8767
R a i s e d 1/ 2 ", o p e n , e a r s 2 - 3 / 4 " O . C .
3.0
25
756
R a i s e d 5 / 8", o p e n , e a r s 2 - 3 / 4 " O . C .
4.0
100
8756
R a i s e d 5 / 8", o p e n , e a r s 2 - 3 / 4 " O . C .
4.0
759
R a i s e d 3 / 4", o p e n , e a r s 2 - 3 / 4 " O . C .
757
R a i s e d 1", o p e n , e a r s 2 - 3 / 4 " O . C .
758
UPC
BAR
CODE
MAX. RECOMMENDED
S U P P O R T L OA D S
CEILING FAN
FIXTURE
(DYNAMIC)
(STATIC)
LBS.
LBS.
No
No
No
No
No
No
No
No
No
No
No
No
No
50
No
50
No
50
100
No
50
5.0
25
No
50
6.8
25
No
50
25
No
50
*5 Bundles of 10
4 " S Q U A R E C O M B I N AT I O N D E V I C E A N D T I L E C O V E R S S I N G L E D E V I C E
C ATA L O G
NUMBER
DESCRIPTION
CU.
IN.
S T D.
PKG.
UPC
BAR CODE
787
Flat
50
8787
Flat
50
771
R a i s e d 1/ 4 "
1.5
100
8771
R a i s e d 1/ 4 "
1.5
25
772
R a i s e d 1/ 2 ", d r a w n
3.5
100
8772
R a i s e d 1/ 2 ", d r a w n
3.5
50
782
R a i s e d 1/ 2 ", t i l e
3.5
25
8782
R a i s e d 1/ 2 ", t i l e
3.5
25
768
R a i s e d 5 / 8"
4.5
50
8768
R a i s e d 5 / 8"
4.5
50
773
R a i s e d 3 / 4"
5.5
50
8773
R a i s e d 3 / 4"
5.5
50
774
Raised 1"
7.5
25
775
R a i s e d 1 -1/ 4 "
9.5
25
8775
R a i s e d 1 -1/ 4 "
9.5
25
785
R a i s e d 1 -1/ 2 "
11.3
25
786
Raised 2"
14.5
25
A30
4 " S Q U A R E C O V E R S A N D PA R T I T I O N S
Applications
Covers are used to close an
outlet box
Raised device covers are used for
mounting switches or receptacles
Product Feature
Angled mounting slots compensate
up to 12 for box misalignment
Low Voltage Partitions
Applications
Low voltage partitions may be
added to conduit-type boxes to
divide power from voice/data
777-781, 769,
8769-8781
791
708
795, 796
O R D E R I N G I N F O R M AT I O N - D I M E N S I O N S
4 " S Q U A R E C O M B I N AT I O N D E V I C E A N D T I L E C O V E R S T W O D E V I C E
C ATA L O G
NUMBER
CU.
IN.
DESCRIPTION
UPC
BAR CODE
791
Flat
777
R a i s e d 1/ 4 ", d r a w n
3.0
50
778
R a i s e d 1/ 2 ", d r a w n
5.5
50
8778
R a i s e d 1/ 2 ", d r a w n
5.5
50
769
R a i s e d 5 / 8", d r a w n
7.3
50
8769
R a i s e d 5 / 8", d r a w n
7.3
50
779
R a i s e d 3 / 4", d r a w n
8.8
50
8779
R a i s e d 3 / 4", d r a w n
8.8
50
780
12.0
25
Compliances
781
R a i s e d 1 -1/ 4 ", d r a w n
15.0
25
8781
R a i s e d 1 -1/ 4 ", d r a w n
15.0
25
795
R a i s e d 1 -1/ 2 ", w e l d e d
15.5
25
796
20.5
25
File E195978
File LR-1082
S T D.
PKG.
50
DESCRIPTION
S T D.
PKG.
UPC
BAR CODE
F o r 1 - 1/ 2 " D e e p B o x a n d 2 - D e v i c e R a i s e d C o v e r * :
706
25
708
25
F o r 2 - 1/ 8 " D e e p B o x a n d 2 - D e v i c e R a i s e d C o v e r : *
707
25
709
25
* B o x e s , c o v e r s , a n d p a r t i t i o n s m u s t b e o r d e r e d s e p a r at e l y
* F o r 1 - 1 / 2 " d e e p b o x w i t h 5 / 8 " c o v e r, p a r t i t i o n n o t av a i l a b l e
* F o r 2 - 1 / 8 " d e e p b o x w i t h 5 / 8 " c o v e r, u s e # 7 0 8 p a r t i t i o n
A31
Application
Product Features
800
803
902
907
801,
811, 812
906
810
813
808
814
915
809
O R D E R I N G I N F O R M AT I O N - D I M E N S I O N S
DESCRIPTION
CU.
IN.
S T D.
PKG.
800
1 To g g l e s w i t c h , c r u s h e d c o r n e r s
5.8
25
803
2 To g g l e s w i t c h e s
7.3
10
902
5.8
25
File E195978
907
2 Duplex receptacles
7.3
25
File LR-1082
801
7.3
10
811
7.3
10
812
7.3
10
906
7.3
10
810
7.3
10
813
7.3
10
808
1 GFCI
7.3
10
814
1 G F C I & 1 t o gg l e s w i t c h
7.3
10
915
7.3
10
809
2 GFCI
7.3
10
UPC
BAR CODE
A32
Application
Extension rings provide a
means for adding additional
cubic capacity or as an outlet
box for surface conduit
Product Feature
Combination screw heads provide
for faster installation
Compliance
File E195978
187
203, 8203
202
201, 8201
O R D E R I N G I N F O R M AT I O N - D I M E N S I O N S
4" SQUARE EXTENSION RINGS 1-1/2" DEEP DRAWN
WITH CONDUIT KOS 22.5 CUBIC INCHES
DESCRIPTION
KNOCKOUTS
C ATA L O G
BRACKET &
SIDES
B OT T O M
NUMBER
SETBACK
C O N D.
C O N D.
S T D.
PKG.
UPC
BAR
CODE
201
1 2 - 1/ 2 "
50
8201
1 2 - 1/ 2 "
25
202
8 -3/ 4 "
50
203
50
8203
50
187
8 - 1/ 2 ", 4 - 3/ 4 "
50
DIMENSIONS
C ATA L O G
NUMBER
201, 8201
1-1/2"
202
1-1/2"
203, 8203
1-1/2"
187
1-1/2"
A33
Applications
246
245
247
257, 8257
NEW
Product Features
RACO offers a variety of labor
saving mounting brackets that
allow for easy positioning of box
along studs or joists
258
12-1/2"
3-1/2" , 2-3/4"
25
10-3/4"
3-1/2" , 2-3/4"
25
247
8-1/2", 4- 3/4"
3-1/2", 2-3/4"
25
S T D.
PKG.
UPC
BAR
CODE
250V
257
2 - 1 / 2 ", 1 0 - T K O
1 - 1 / 2 ", 2 - 3 / 4 " ,
2-TKO
25
250V
8257
2 - 1 / 2 ", 1 0 - T K O
1 - 1 / 2 ", 2 - 3 / 4 " ,
2-TKO
25
258
8-1"
3 - 1 / 2 ", 2 - 3 / 4 "
25
259
6 - 1 1 / 4"
3 - 1 / 2 ", 2 - 3 / 4 "
25
265
4 - 3 / 4 ", 4 - 1 "
3 - 1 / 2 ", 2 - 3 / 4 "
25
8265
4 - 3 / 4 ", 4 - 1 "
3 - 1 / 2 ", 2 - 3 / 4 "
25
1 - 1 / 2 ", 2 - 3 / 4 " ,
2-TKO
25
1 - 1 / 2 ", 2 - 3 / 4 " ,
2-TKO
25
250V
250V
UPC
BAR
CODE
246
250V
S T D.
PKG.
245
Compliance
266 BOX-LOC
O R D E R I N G I N F O R M AT I O N - D I M E N S I O N S
254
265, 8265
259
254
266
FM brkt.
2 - 1 / 2 ", 7 - T K O
BOX-LOC
MS flush
2 - 1 / 8 ",
10-TKO
DIMENSIONS
C ATA L O G
NUMBER
245
1-1/2"
246
1-1/2"
247
1-1/2"
257, 8257
2-1/8"
258
2-1/8"
259
2-1/8"
265, 8265
2-1/8"
254
2-1/8"
7-5/8"
5-1/16"
266
2-1/8"
A34
Applications
Extension rings provide
a means for adding additional
cubic capacity or as an outlet
box for surface conduit
Covers are used to close
an outlet box
250
262
833, 8833-5
832, 8832
File E195978
File LR-1082
829, 835
837-839, 842-843
898-899
O R D E R I N G I N F O R M AT I O N - D I M E N S I O N S
4-11/16" SQUARE EXTENSION 1-1/2" DEEP DRAWN
WITH CONDUIT KOS 29.5 CUBIC INCHES
KNOCKOUTS
DESCRIPTION
C ATA L O G
BRACKET &
SIDES
B OT T O M
NUMBER
SETBACK
C O N D.
C O N D.
250
STD
P K G.
UPC
BAR
CODE
25
STD
P K G.
UPC
BAR
CODE
25
C ATA L O G
NUMBER
DESCRIPTION
CU.
IN.
S T D.
PKG.
UPC
BAR
CODE
MAX. RECOMMENDED
S U P P O R T L OA D S
C E I L I N G FA N F I X T U R E
( DY N A M I C )
( S TAT I C )
LBS.
LBS.
832
Flat, blank
50
8832
Flat, blank
50
No
No
No
No
833
F l a t , 1 / 2 "K O c e n t e r e d
50
829
R a i s e d 1/ 2 ", o p e n , e a r s 2 - 3 / 4 " O . C .
3.0
25
No
No
No
835
R a i s e d 5/ 8 ", o p e n , e a r s 2 - 3 / 4 " O . C .
4.0
25
No
50
50
8833-5
F l a t , 1/ 2 " K O c e n t e r e d
50*
No
No
*5 Bundles of 10
4 - 1 1 / 1 6 " S Q U A R E C O M B I N AT I O N D E V I C E A N D T I L E C O V E R S S I N G L E D E V I C E
C ATA L O G
NUMBER
DESCRIPTION
CU.
IN.
S T D.
PKG.
UPC
BAR CODE
837
R a i s e d 1/ 2 "
3.5
25
843
R a i s e d 5/ 8 "
4.5
25
838
R a i s e d 3/ 4 "
5.5
25
839
Raised 1"
7.5
25
842
R a i s e d 1 - 1/ 4"
9.5
25
898
R a i s e d 1 -1/ 2 "
11.0
20
899
Raised 2"
16.0
20
DIMENSIONS
C ATA L O G
NUMBER
250
1-1/2"
262
2-1/8"
A35
Applications
818-820,
840, 841
885
972
870RAC
979
887
888
857
856
878
858
959
O R D E R I N G I N F O R M AT I O N - D I M E N S I O N S
4 - 1 1 / 1 6 " S Q U A R E C O M B I N AT I O N D E V I C E A N D T I L E C O V E R S T W O D E V I C E
C ATA L O G
NUMBER
DESCRIPTION
CU.
IN.
S T D.
PKG.
UPC
BAR CODE
841
R a i s e d 1/ 2 "
5.5
Compliances
818
Raised 5 / 8"
7.3
25
840
R a i s e d 3/ 4 "
8.8
25
819
Raised 1"
12.0
25
820
15.0
25
885
15.5
20
File E195978
File LR-1082
25
DESCRIPTION
S T D.
PKG.
870RAC
1 To g g l e s w i t c h
972
1 Duplex receptacle
10
979
2 Duplex receptacles
10
887
10
888
10
878
10
856
1 D e c o r a t o r d e v. o r G F C I
10
857
2 D e c o r a t o r d e v. o r G F C I
10
858
1 To g g l e & 1 G F C I
10
959
10
UPC
BAR CODE
10
DESCRIPTION
S T D.
PKG.
UPC
BAR CODE
F o r 1 - 1/ 2 " d e e p b o x a n d 2 - d e v i c e r a i s e d c o v e r :
706
25
708
25
F o r 2 - 1/ 8 " d e e p b o x a n d 2 - d e v i c e r a i s e d c o v e r : *
707
25
709
1 - 1/ 4 " o r 1 - 1/ 2 " ( 8 2 0 , 8 8 5 )
25
* B o x e s , c o v e r s a n d p a r t i t i o n s m u s t b e o r d e r e d s e p a r at e l y
* F o r 2 - 1 / 8 " d e e p b o x w i t h 5 / 8 " c o v e r, u s e # 7 0 8 p a r t i t i o n
* P a r t i t i o n s a r e u s e ab l e , b u t n o t U L l i s t e d i n 4 - 1 1 / 1 6 " s q . b o x
A36
HANDY BOXES
1-1/2" AND 1-7/8" DEEP
Applications
Handy Boxes, also called utility
boxes, are used for convenience
outlets, switch boxes or small
junction boxes
They are popular for exposed
work applications (surface
mounted wiring)
655
650, 8650
660, 8660
663, 8663
611
661
662
O R D E R I N G I N F O R M AT I O N - D I M E N S I O N S
4" x 2" HANDY BOXES 1-1/2" DEEP WELDED
WITH CONDUIT KOS 11.5 CUBIC INCHES
DESCRIPTION
C ATA L O G
KNOCKOUTS
BRACKET &
NUMBER
SETBACK
SIDES
ENDS
B OT T O M
S T D.
PKG.
UPC
BAR
CODE
650
6-1/ 2"
2 - 1/ 2"
3-1/ 2"
50
Compliances
8650
6-1/ 2"
2 - 1/ 2"
3-1/ 2"
50
655
B brkt., 1/ 4"
3-1/ 2"
2 - 1/ 2"
3-1/ 2"
50
S T D.
PKG.
UPC
BAR
CODE
File E195978
File LR-1082 (611 only)
B OT T O M
660
6 - 1/ 2 "
2 - 1/ 2 "
3-1/ 2"
50
8660
6 - 1/ 2 "
2 - 1/ 2 "
3-1/ 2"
50
611
6-1/ 2"
2 - 1/ 2"
3-1/ 2"
50
663
4 - 3/ 4 "
2 - 3/ 4 "
2-3/ 4"
50
8663
4 - 3/ 4 "
2 - 3/ 4 "
2-3/ 4"
50
662
TS brkt., 1/ 2"
3-1/ 2"
2 - 1/ 2"
3-1/ 2"
50
661
A brkt., 5/ 8"
3-1/ 2"
2 - 1/ 2"
3-1/ 2"
50
DIMENSIONS
C ATA L O G
NUMBER
650, 8650
1-1/2"
655
1-1/2"
660, 8660
1-7/8"
611
1-7/8"
663, 8663
1-7/8"
662
1-7/8"
7"
2-3/8"
661
1-7/8"
6-7/16"
2-11/32"
A37
Applications
674
670RAC, 8670
678
671
665
653
880
640
O R D E R I N G I N F O R M AT I O N - D I M E N S I O N S
4" x 2" HANDY BOXES 2-1/8" DEEP WELDED
WITH CONDUIT KOS 16.5 CUBIC INCHES
C ATA L O G
NUMBER
DESCRIPTION
BRACKET &
SETBACK
670RAC
8670
S T D.
PKG.
UPC
BAR
CODE
3-1/ 2"
50
3-1/ 2"
50
KNOCKOUTS
SIDES
ENDS
B OT T O M
6-1/ 2"
2 - 1/ 2"
6-1/ 2"
2 - 1/ 2"
674
4 -3/ 4 "
2 - 3/ 4 "
2 - 3/ 4 "
50
678
TS brkt., 1/ 2"
3-1/ 2"
2 - 1/ 2"
3-1/ 2"
50
671
A brkt., 5/ 8"
3-1/ 2"
2 - 1/ 2"
3-1/ 2"
50
Compliances
File E195978
6-1/ 2"
2 - 1/ 2 "
6-1/ 2"
2 - 1/ 2"
S T D.
PKG.
UPC
BAR
CODE
25
S T D.
PKG.
UPC
BAR
CODE
50
B l a n k c o v e r & c ap t i v e s c r e w s
6-1/ 2"
2 - 1/ 2 "
3 - 1/ 2 "
50
50
DIMENSIONS
C ATA L O G
NUMBER
670, 8670
2-1/8"
674
2-1/8"
678
2-1/8"
7"
2-3/8"
671
2-1/8"
7"
2-3/8"
653
1-1/2"
665
1-7/8"
A38
Applications
Handy Box covers are used
to close a Handy Box
Covers also may be used as
single-gang wall plates
Product Features
865
861
860
863, 867
864
O R D E R I N G I N F O R M AT I O N - D I M E N S I O N S
DESCRIPTION
S T D.
PKG.
860
Blank
25
861
1/ 2" KO centered
25
865
To g g l e s w i t c h
25
864
Duplex receptacle
25
863
25
867
25
UPC
BAR CODE
A39
SWITCH BOXES
SINGLE-GANG 1" DEEP
Application
RACO STEEL BOXES
& COVERS
404
418
405
O R D E R I N G I N F O R M AT I O N - D I M E N S I O N S
3-3/4" x 2" SWITCH BOXES 1" DEEP NONGANGABLE WELDED
W I T H N O N M E TA L L I C S H E AT H E D C A B L E C L A M P S 6 . 5 C U B I C I N C H E S
C ATA L O G
NUMBER
DESCRIPTION
BRACKET &
SETBACK
SIDE
C O N D.
404
Q clamp, 1/4"
405
Q clamp, 1/4"
KNOCKOUTS
ENDS
B OT T O M
COND
C A B L E C O N D.
2
1-1/ 2"
S T D.
PKG.
UPC
BAR
CODE
25
25
DESCRIPTION
BRACKET &
SETBACK
SIDE
C O N D.
418
KNOCKOUTS
ENDS
B OT T O M
COND
C A B L E C O N D.
4
2 - 1/ 2"
S T D.
PKG.
25
UPC
BAR
CODE
A40
SWITCH BOXES
SINGLE-GANG 1-1/2" AND 2" DEEP
Application
Switch boxes are used to house
wiring devices such as switches
or outlets
Product Features
Gangable switch boxes offer the
option of constructing a box to
hold two or more devices
410
400
File E195978
420, 8420
445
O R D E R I N G I N F O R M AT I O N - D I M E N S I O N S
3" x 2" SWITCH BOX 1-1/2" DEEP GANGABLE
WITH CONDUIT KOS 7.5 CUBIC INCHES
C ATA L O G
NUMBER
400
DESCRIPTION
BRACKET &
SETBACK
KNOCKOUTS
Ears
SIDES
ENDS
B OT T O M
2 - 1/ 2 "
1-1/ 2"
S T D.
PKG.
UPC
BAR
CODE
20
DESCRIPTION
BRACKET &
SETBACK
Ears
SIDES
C O N D.
KNOCKOUTS
ENDS
B OT T O M
COND
C A B L E C O N D.
4
B OT T O M
S T D.
PKG.
UPC
BAR
CODE
50
S T D.
PKG.
UPC
BAR
CODE
420
Ears
4-1/ 2"
2 - 1/ 2"
2 - 1/ 2"
50
8420
Ears
4-1/ 2"
2 - 1/ 2"
2 - 1/ 2"
50
DESCRIPTION
BRACKET &
SETBACK
Ears
SIDES
C O N D.
KNOCKOUTS
ENDS
B OT T O M
COND
C A B L E C O N D.
4
1-1/ 2"
DIMENSIONS
C ATA L O G
NUMBER
400
1-1/2"
410
1-1/2"
420, 8420
2"
445
2"
S T D.
PKG.
UPC
BAR
CODE
50
A41
SWITCH BOXES
S I N G L E - G A N G 2 ", 2 - 1 / 8 " A N D 2 - 1 / 4 " D E E P
ING
COM ON
SO
Application
Product Features
Gangable boxes offer the option
of constructing a box to hold
two or more devices
513
440
471, 8471
473
O R D E R I N G I N F O R M AT I O N - D I M E N S I O N S
Compliances
487
C ATA L O G
NUMBER
DESCRIPTION
BRACKET &
SETBACK
SIDE
C O N D.
440
Ears
KNOCKOUTS
ENDS
B OT T O M
COND
C A B L E C O N D.
4
1-1/ 2"
S T D.
PKG.
UPC
BAR
CODE
50
DESCRIPTION
BRACKET &
SETBACK
C ATA L O G
NUMBER
O l d Wo r k W i t h S n a p I n
Clips And Ears
KNOCKOUTS
SIDES
2-1/2"
ENDS
B OT T O M
1-1/2"
2-1/ 2"
S T D.
PKG.
UPC
BAR
CODE
24
DESCRIPTION
BRACKET &
SETBACK
SIDE
C O N D.
471
Ears
8471
Ears
473
Level bumps
487
KNOCKOUTS
ENDS
B OT T O M
COND
C A B L E C O N D.
4
1-1/ 2"
C ATA L O G
NUMBER
UPC
BAR
CODE
50
2-1/ 2"
1-1/ 2"
20
1-1/ 2"
20
DIMENSIONS
A
440
2"
471, 8471
2-1/4"
473
2-1/4"
487
2-1/4"
1-1/ 2"
S T D.
PKG.
50
A42
SWITCH BOXES
SINGLE-GANG 2-1/2" DEEP
Application
Switch boxes are used to house
wiring devices such as switches
or outlets
Product Features
500, 503, 8500
File E195978
502
501
ING
COM ON
SO
506
O R D E R I N G I N F O R M AT I O N - D I M E N S I O N S
3" x 2" SWITCH BOXES 2-1/2" DEEP GANGABLE
WITH CONDUIT KOS 12.5 CUBIC INCHES
DESCRIPTION
C ATA L O G
KNOCKOUTS
BRACKET &
NUMBER
SETBACK
SIDES
ENDS
B OT T O M
S T D.
PKG.
UPC
BAR
CODE
500
Ears
4-1/ 2"
2 - 1/ 2"
2 - 1/ 2"
50
8500
Ears
4-1/ 2"
2 - 1/ 2"
2 - 1/ 2"
50
503
Ears
4-1/2"
2 - 3/ 4"
2 - 1/ 2"
50
501
Without ears
4-1/ 2"
2 - 1/ 2"
2 - 1/ 2"
50
504
TS brkt., 1/ 2"
2-1/ 2"
2 - 1/ 2"
2 - 1/ 2"
50
8504
TS brkt., 1/ 2"
2-1/ 2"
2 - 1/ 2"
2 - 1/ 2"
10
505
TS brkt., 1/ 2"
2-1/ 2"
2 - 3/ 4"
2 - 1/ 2"
50
502
B brkt., 5/ 8"
4-1/ 2"
2 - 1/ 2"
2 - 1/ 2"
10
506
2 - 1/ 2"
2 - 1/ 2"
20
509
Old work
2 - 1/ 2"
2 - 1/ 2"
20
508
509
Old work
2 - 1/ 2"
B OT T O M
S T D.
PKG.
20
DIMENSIONS
C ATA L O G
NUMBER
500, 8500
2-1/2"
503
2-1/2"
501
2-1/2"
504, 8504
2-1/2"
7-5/32"
2-5/16"
502
2-1/2"
2"
4"
506
2-1/2"
508
2-1/2"
509
2-1/2"
UPC
BAR
CODE
A43
SWITCH BOXES
SINGLE-GANG 2-1/2" DEEP
Application
Product Features
RACO offers a variety of labor
saving mounting brackets that
allow for easy positioning of box
along studs or joists
528, 8528
519, 8519
ING
COM ON
SO
517
531, 8531
540
596
512
545
O R D E R I N G I N F O R M AT I O N - D I M E N S I O N S
Compliances
File E195978
DESCRIPTION
BRACKET &
SETBACK
C ATA L O G
NUMBER
529
SIDE
C O N D.
KNOCKOUTS
ENDS
B OT T O M
COND
C A B L E C O N D.
4
1 - 1/ 2 "
S T D.
PKG.
UPC
BAR
CODE
50
519
Ears
8519
Ears
1 - 1/ 2 "
50
528
Level bumps
2 - 1/ 2 "
1 - 1/ 2 "
50
8528
Level bumps
2 - 1/ 2 "
1 - 1/ 2 "
50
531
T S b r k t . , 1/ 2 "
2 - 1/ 2 "
1 - 1/ 2 "
50
8531
T S b r k t . , 1/ 2 "
2 - 1/ 2 "
1 - 1/ 2 "
50
540
B b r k t . , 1/ 4 "
2 - 1/ 2 "
1 - 1/ 2 "
50
529
2 - 1/ 2 "
1 - 1/ 2 "
50
517
O l d w o r k , Ti g e r g r i p
1 - 1/ 2 "
20
512
Old work
1 - 1/ 2 "
20
DESCRIPTION
BRACKET &
SETBACK
596
Without ears
545
Old work
SIDE
C O N D.
KNOCKOUTS
ENDS
B OT T O M
C A B L E C O N D.
COND
4
2 - 1/ 2 "
1 - 1/ 2 "
4
2 - 1/ 2 "
S T D.
PKG.
UPC
BAR
CODE
50
20
DIMENSIONS
C ATA L O G
NUMBER
519, 8519
2-1/2"
528, 8528
2-1/2"
531, 8531
2-1/2"
7-5/32"
2-5/16"
540
2-1/2"
13-1/32"
5-3/64"
529
2-1/2"
13-1/32"
5-3/64"
517
2-1/2"
596
2-1/2"
545
2-1/2"
A44
SWITCH BOXES
SINGLE-GANG 2-1/2" DEEP
Application
Switch boxes are used to house
wiring devices such as switches
or outlets
Product Features
RACO offers a variety of labor
saving mounting brackets that
allow for easy positioning of box
along studs or joists
524, 8524
518, 8518
522, 8522
526
523, 8523
O R D E R I N G I N F O R M AT I O N - D I M E N S I O N S
Compliances
File E195978
C ATA L O G
NUMBER
DESCRIPTION
BRACKET &
SETBACK
SIDE
C O N D.
KNOCKOUTS
ENDS
B OT T O M
COND
C A B L E C O N D.
4
1 - 1/ 2 "
S T D.
PKG.
UPC
BAR
CODE
50
518
Ears
8518
Ears
1 - 1/ 2 "
50
524
T S b r k t . , 1/ 2 "
2 - 1/ 2 "
1 - 1/ 2 "
50
8524
T S b r k t . , 1/ 2 "
2 - 1/ 2 "
1 - 1/ 2 "
50
522
Long B, 5/ 8"
2 - 1/ 2 "
1 - 1/ 2 "
50
8522
Long B, 5/ 8"
2 - 1/ 2 "
1 - 1/ 2 "
50
523
1 - 1/ 2 "
50
8523
1 - 1/ 2 "
50
DESCRIPTION
BRACKET &
SETBACK
526
Old work
SIDE
C O N D.
KNOCKOUTS
ENDS
C A B L E C O N D.
4
B OT T O M
COND
S T D.
PKG.
20
DIMENSIONS
C ATA L O G
NUMBER
518, 8518
2-1/2"
524, 8524
2-1/2"
7-5/32"
2-5/16"
522, 8522
2-1/2"
13-1/32"
5-3/64"
526
2-1/2"
1-3/8"
3-13/32"
UPC
BAR
CODE
A45
SWITCH BOXES
SINGLE-GANG 2-3/4" AND 2-27/32" DEEP
Application
RACO STEEL BOXES
& COVERS
File E195978
355, 8355
353
561
562
O R D E R I N G I N F O R M AT I O N - D I M E N S I O N S
3" x 2-1/8" SWITCH BOX 2-27/32" DEEP NONGANGABLE
W I T H A R M O R E D C A B L E / M E TA L C L A D / F L E X C L A M P S 1 5 . 8 C U B I C I N C H E S
C ATA L O G
NUMBER
DESCRIPTION
BRACKET &
SETBACK
SIDE
C O N D.
353
S brkt., nails
KNOCKOUTS
ENDS
B OT T O M
COND
C A B L E C O N D.
4
1 - 1/ 2 "
S T D.
PKG.
UPC
BAR
CODE
50
SIDE
C O N D.
355
S brkt., nails
8355
S brkt., nails
C ATA L O G
NUMBER
KNOCKOUTS
ENDS
B OT T O M
COND
C A B L E C O N D.
4
1 - 1/ 2 "
4
1 - 1/ 2 "
S T D.
PKG.
50
UPC
BAR
CODE
20
S T D.
PKG.
UPC
BAR
CODE
560
Ears
4 - 1/ 2 "
2 - 1/ 2 "
2 - 1/ 2 "
50
8560
Ears
4 - 1/ 2 "
2 - 1/ 2 "
2 - 1/ 2 "
50
565
Ears
4 - 1/ 2 "
2 - 3/ 4"
2 - 1/ 2 "
50
561
Without ears
4 - 1/ 2 "
2 - 1/ 2 "
2 - 1/ 2 "
50
562
T S b r k t . , 1/ 2 "
2 - 1/ 2 "
2 - 1/ 2 "
2 - 1/ 2 "
50
560, 8560
2-3/4"
565
2-3/4"
562
2-3/4"
7-5/32"
2-5/16"
561
2-3/4"
7-5/32"
2-5/16"
A46
SWITCH BOXES
SINGLE-GANG 2-3/4" AND 3-1/2" DEEP
Application
Switch boxes are used to house
wiring devices such as switches
or outlets
Product Features
567
574
564
570RAC
592
O R D E R I N G I N F O R M AT I O N - D I M E N S I O N S
Compliances
File E195978
DESCRIPTION
BRACKET &
SETBACK
SIDE
C O N D.
567
Ears
4 - 1/ 2 "
564
T S b r k t . , 1/ 2 "
2 - 1/ 2 "
KNOCKOUTS
ENDS
B OT T O M
COND
C A B L E C O N D.
4
2 - 1/ 2 "
1 - 1/ 2 "
4
2 - 1/ 2 "
UPC
BAR
CODE
50
50
DESCRIPTION
BRACKET &
SETBACK
SIDE
C O N D.
570RAC
Ears
4 - 1/ 2 "
574
T S b r k t . , 1/ 2 "
2 - 1/ 2 "
KNOCKOUTS
ENDS
B OT T O M
COND
C A B L E C O N D.
4
2 - 1/ 2 "
1 - 1/ 2 "
4
2 - 1/ 2 "
1 - 1/ 2 "
S T D.
PKG.
1 - 1/ 2 "
B OT T O M
S T D.
PKG.
UPC
BAR
CODE
50
50
S T D.
PKG.
UPC
BAR
CODE
590
Ears
4 - 1/ 2 "
4 - 1/ 2 "
1 - 1/ 2 "
50
8590
Ears
4 - 1/ 2 "
4 - 1/ 2 "
1 - 1/ 2 "
50
591
Ears
4-3/ 4"
4-3/ 4"
1 - 1/ 2 "
50
592
Without ears
4 - 1/ 2 "
4 - 1/ 2 "
1 - 1/ 2 "
50
DIMENSIONS
C ATA L O G
NUMBER
567
2-3/4"
564
2-3/4"
7-5/32"
2-5/16"
570RAC
2-3/4"
574
2-3/4"
7-5/32"
2-5/16"
590, 8590
3-1/2"
591
3-1/2"
592
3-1/2"
A47
SWITCH BOXES
SINGLE-GANG 3-1/2" DEEP
Application
RACO STEEL BOXES
& COVERS
601, 8601
605
File E195978
603
604, 8604
600
O R D E R I N G I N F O R M AT I O N - D I M E N S I O N S
3" x 2" SWITCH BOXES 3-1/2" DEEP GANGABLE
W I T H N O N M E TA L L I C S H E AT H E D C A B L E C L A M P S 1 8 . 0 C U B I C I N C H E S
KNOCKOUTS
ENDS
B OT T O M
COND
C A B L E C O N D.
4
2 - 1/ 2 "
1 - 1/ 2 "
DESCRIPTION
BRACKET &
SETBACK
SIDE
C O N D.
601
Ears
4 - 1/ 2 "
8601
Ears
4 - 1/ 2 "
605
T S b r k t . , 1/ 2 "
4 - 1/ 2 "
2 - 1/ 2 "
1 - 1/ 2 "
25
603
B brkt., 5/ 8"
4 - 1/ 2 "
2 - 1/ 2 "
1 - 1/ 2 "
25
C ATA L O G
NUMBER
2 - 1/ 2 "
1 - 1/ 2 "
S T D.
PKG.
UPC
BAR
CODE
25
25
DESCRIPTION
BRACKET &
SETBACK
SIDE
C O N D.
KNOCKOUTS
ENDS
B OT T O M
COND
C A B L E C O N D.
4
2 - 1/ 2 "
1 - 1/ 2 "
S T D.
PKG.
UPC
BAR
CODE
600
Ears
4 - 1/ 2 "
25
604
T S b r k t . , 1/ 2 "
4 - 1/ 2 "
2 - 1/ 2 "
1 - 1/ 2 "
25
8604
T S b r k t . , 1/ 2 "
4 - 1/ 2 "
2 - 1/ 2 "
1 - 1/ 2 "
25
DIMENSIONS
C ATA L O G
NUMBER
601, 8601
3-1/2"
605
3-1/2"
7-5/32"
2-5/16"
603
3-1/2"
1-31/32"
4"
600
3-1/2"
604, 8604
3-1/2"
7-5/32"
2-5/16"
A48
SWITCH BOXES
TWO-GANG 2-1/8" DEEP
Applications
Installers can save time and cut
installation costs with two-gang
switch boxes
These larger capacity boxes are
ideal for todays designs where
there is a need to install two
devices at one location
680
685
681
683
File E195978
871
873
872
O R D E R I N G I N F O R M AT I O N - D I M E N S I O N S
4" SQUARE TWO DEVICE SWITCH BOX 2-1/8" DEEP DRAWN
WITH CONDUIT KOS 30.3 CUBIC INCHES
KNOCKOUTS
C ATA L O G
NUMBER
DESCRIPTION
BRACKET &
SETBACK
680
12-1/ 2"
5-1/ 2"
683
8 - 1 / 2 " , 4 - 3/ 4 "
3 - 1 / 2 " , 2 - 3/ 4 "
25
681
TS brkt., 1/ 2"
9-1/ 2"
5-1/ 2"
25
685
TS brkt., 1/ 2"
6 - 3/ 4 "
3 - 1 / 2 " , 2 - 3/ 4 "
25
SIDES
C O N D.
UPC
BAR
CODE
S T D.
PKG.
B OT T O M
C O N D.
25
4 " S Q U A R E T W O - D E V I C E W A L L P L AT E S *
C ATA L O G
NUMBER
DESCRIPTION
S T D.
PKG.
871
872
2 To g g l e s w i t c h e s
1 D u p . & 1 To g g l e s w i t c h
25
25
873
2 Duplex receptacles
25
UPC
BAR CODE
680
4"
4"
2-1/8"
683
4"
4"
2-1/8"
681
4"
4"
2-1/8"
7"
4-9/32"
685
4"
4"
2-1/8"
7"
4-9/32"
A49
SWITCH BOXES
M U LT I - G A N G 2 - 1 / 2 " D E E P
Applications
RACO STEEL BOXES
& COVERS
686
687
971
O R D E R I N G I N F O R M AT I O N - D I M E N S I O N S
M U LT I - D E V I C E S W I T C H B O X E S 2 - 1 / 2 " D E E P W E L D E D
WITH CONDUIT KOS
DESCRIPTION
C ATA L O G
KNOCKOUTS
BRACKET &
NUMBER
SETBACK
SIDES
ENDS
B OT T O M
C U . I N . S T D.
C A P.
PKG.
686
3-Gang
1/2" setback
10
687
4-Gang
1/2" setback
10
971
Low voltage
partition
25
UPC
BAR
CODE
686
5-9/16"
3-3/4"
2-1/2"
7-5/8"
5-31/32"
687
7-3/8"
3-3/4"
2-1/2"
7-5/8"
7-25/32"
A50
G A N G B O X E S , PA R T I T I O N S A N D C O V E R S
1-5/8" AND 2-1/2" DEEP
Application
Gang boxes are used where
a number of wiring devices are
to be centrally located
958
952
951
Product Features
NEW
NEW
941
NEW
942
NEW
NEW
944
943
945
O R D E R I N G I N F O R M AT I O N - D I M E N S I O N S
File E195978
C ATA L O G N O. O F
NUMBER GANGS DEPTH
KNOCKOUTS
WIDTH
T O P & B OT T O M * S I D E S *
BACK
CU.
IN.
UPC
S T D. B A R
PKG. CODE
951
1-5/8" 6-13/16
8-conc.
47.0
952
1-5/8" 8-5/8
10-conc.
60.0
953
1-5/8" 10-7/16
12-conc.
72.8
954
1-5/8" 12-1/4
14-conc.
85.8
955
1-5/8" 14-1/16
16-conc.
98.5
956
1-5/8" 15-7/8
18-conc.
957
958
1-5/8" 19-1/2
22-conc.
941
2-1/2" 6-13/16
70.0
942
2-1/2" 8-5/8
90.0
943
2-1/2" 10-7/16
944
2-1/2" 12-1/4
945
2-1/2" 14-1/16
25
DIMENSIONS
C ATA L O G
NUMBER
N O. O F
GANGS
951
1-5/8"
6-3/8"
6-13/16"
952
1-5/8"
8-3/16"
8-5/8"
953
1-5/8"
10"
10-7/16"
954
1-5/8"
11-13/16"
12-1/4"
955
1-5/8"
13-5/8"
14-1/16"
956
1-5/8"
15-7/16"
15-7/8"
957
1-5/8"
17-1/4"
17-11/16"
958
1-5/8"
19-1/16"
19-1/2"
941
2-1/2"
6-3/8"
6-13/16"
942
2-1/2"
8-3/16"
8-5/8"
943
2-1/2"
10"
10-7/16"
944
2-1/2"
11-13/16"
12-1/4"
945
2-1/2"
13-5/8"
14-1/16"
A51
G A N G B O X E S , PA R T I T I O N S A N D C O V E R S
Application
RACO STEEL BOXES
& COVERS
846
974
823
O R D E R I N G I N F O R M AT I O N - D I M E N S I O N S
F L A T, B L A N K C O V E R S F O R G A N G B O X E S
C ATA L O G
NUMBER
N O. O F
GANGS
844
7 - 1/ 1 6 "
845
8 - 7/ 8 "
846
10 -11/ 16"
847
1 2 - 1/ 2 "
848
1 4 - 5/ 1 6 "
849
1 6 - 1/ 8 "
850
1 7 - 15/ 1 6 "
851
1 9 - 3/ 4 "
WIDTH
CU.
IN.
S T D.
PKG.
UPC
BAR CODE
N O. O F
GANGS
CU.
IN.
S T D.
PKG.
821
822
7 -1/ 16"
10.0
8 -7/ 8"
15.3
823
10 -11/ 16"
20.3
824
1 2 -1/ 2 "
25.5
825
14 -5/ 16"
30.5
826
1 6 -1/ 8 "
35.5
827
1 7 -15/ 1 6 "
40.8
828
19 -3/4"
45.8
WIDTH
UPC
BAR CODE
L O W V O LT A G E P A R T I T I O N F O R G A N G B O X E S
NEW
C ATA L O G
NUMBER
DESCRIPTION
S T D.
PKG.
UPC
BAR CODE
974
25
949
25
A52
Applications
Concrete rings are used with
poured deck (floor) in high-rise
construction
These boxes are installed on
wooden or steel concrete forms.
After the forms are removed, the
box is flush with the concrete
284
GORILLA-RING
*280 SHOWN
WITH 918 BARS
891
O R D E R I N G I N F O R M AT I O N - D I M E N S I O N S
CONCRETE RINGS
C ATA L O G
DEPTH
NUMBER
893
892
KO SIZES
N O.
ROWS KOs
CU.
IN.
S T D.
PKG.
MAX. RECOMMENDED
S U P P O R T L OA D S
UPC
C E I L I N G FA N F I X T U R E
BAR CODE
( DY N A M I C )
( S TAT I C )
LBS.
LBS.
270RAC
2"
Single
24.5
25
No
50
271
Single
30.8
25
No
50
272
3"
Single
37.0
25
No
50
277
3"
Single
37.0
25
No
50
273
Double
43.0
20
No
50
278
Single
43.0
20
No
50
274
4"
Double
49.3
20
No
50
279
4"
Double
49.3
20
No
50
275
5"
Double
61.5
10
No
50
Compliance
276
6"
Double
74.0
10
No
50
284
4"
Double
49.3
35
75
File E195978
CU.
IN.
DESCRIPTION
280
918
3 0 " L o n g b a r s fo r h u n g c e i l i n g b o x
S T D.
PKG.
UPC
BAR CODE
43.0
20
40
* O r d e r b a r s s e p a r at e l y
STEEL CONCRETE RINGS
C O N C R E T E R I N G B A C K P L AT E S / C O V E R S A N D A DA P T E R R I N G
C ATA L O G
NUMBER
DESCRIPTION
890
KNOCKOUTS
O. D.
DIAM.
S T D.
PKG.
UPC
BAR CODE
3 - 1 / 2 ", 2 - 3 / 4 "
4-1/2"
25
891
3/ 8" Stud
2 - 1 / 2 ", 2 - 3 / 4 "
4-1/2"
25
892
Flat, blank
4-1/2"
25
893
4-1/2"
50
K N O C K O U T L O C AT I O N S
KNOCKOUT
SIZE
1/2"
3/4"
3/4"
1"
A53
M A S O N RY B O X E S
2-1/2" AND 3-1/2" DEEP
Applications
RACO STEEL BOXES
& COVERS
692
691
690
696
695, 8695
697
971
O R D E R I N G I N F O R M AT I O N - D I M E N S I O N S
MASONRY BOXES 2-1/2" DEEP NONGANGABLE
WITH CONDUIT KOS
CU.
IN.
S T D.
PKG.
UPC
BAR
CODE
16.0
25
31.8
25
47.8
10
63.5
10
9 - 7/ 3 2 "
10
79.5
10
11 1 / 3 2 "
12
95.3
KNOCKOUTS
C ATA L O G
NUMBER
N O. O F
GANGS
WIDTH
690
1-3 1/ 3 2"
691
3 -2 5/ 3 2"
692
5 -19/ 3 2"
693
7 -13/ 3 2"
694
960
ENDS
B OT T O M
B OT T O M
CU.
IN.
S T D.
PKG.
UPC
BAR
CODE
22.5
25
22.5
25
KNOCKOUTS
C ATA L O G
NUMBER
N O. O F
GANGS
ENDS
695
1-3 1/ 3 2"
8695
1-3 1/ 3 2"
696
3 -2 5/ 3 2"
45.0
10
697
5 -1 9/ 3 2"
12
67.3
10
698
7 -13/ 3 2"
16
89.8
10
699
9 - 7/ 3 2 "
20
112.3
10
965
1- 1 1 / 3 2 "
24
134.8
WIDTH
L O W V O LT A G E P A R T I T I O N F O R M A S O N R Y B O X E S
C ATA L O G
NUMBER
DESCRIPTION
S T D.
PKG.
UPC
BAR CODE
971
25
DIMENSIONS
C ATA L O G
NUMBER
N O. O F
GANGS
690
1-31/32"
2-1/2"
691
3-25/32"
2-1/2"
692
5-9/16"
2-1/2"
693
7-13/32"
2-1/2"
694
9-7/32"
2-1/2"
960
1-11/32"
2-1/2"
695,8695
1-31/32"
3-1/2"
696
3-25/32"
3-1/2"
697
5-9/16"
3-1/2"
698
7-13/32"
3-1/2"
699
9-7/32"
3-1/2"
965
1-11/32"
3-1/2"
A54
Application
Adjustable bar hanger allows box
to be placed between ceiling joists
or wall studs quickly and easily
Product Features
Both RACO 920 and 922 bar
fixture hangers allow box to be
located anywhere along length
of bar
RACO 920 includes 3/8" trade
size stud to accommodate
fixture stem
922 Clip installs in 1/2" knockout
located in bottom (back) of box
RACO box must be ordered
separately
920, 8920
922
O R D E R I N G I N F O R M AT I O N - D I M E N S I O N S
Box Installation
A D J U S TA B L E B A R H A N G E R S
C ATA L O G
NUMBER
DESCRIPTION
S T D.
PKG.
UPC
BAR
CODE
920
50
8920
50
922
50
File E195978
MAX. RECOMMENDED
S U P P O R T L OA D S
C E I L I N G FA N
FIXTURE
( DY N A M I C )
( S TAT I C )
LBS.
LBS.
No
10*
No
10*
No
10*
A55
BOX-LOC
980
978
O R D E R I N G I N F O R M AT I O N - D I M E N S I O N S
Repositions easily
Bracket may be added to any
RACO 4" or 4-11/16" square steel
box simply tap the bracket
with a hammer and the barbed
hooks hold it in place
BOX-LOC also fits RACO 7220
and 7232, 4" square PVC boxes
BOX-LOC is a snap to install.
Place the bracket on the open side
of the stud first. Slots in the bracket engage the lip of the stud and
actually crimp it as you press the
bracket on the stud. Barbed hooks
dig into the flat side of the stud,
locking it in place
B O X - L O C M E TA L S T U D C L I P
C ATA L O G
NUMBER
DESCRIPTION
S T D.
PKG.
UPC
BAR CODE
980
Spring-steel bracket
50
DESCRIPTION
S T D.
PKG.
UPC
BAR CODE
50
FA R S I D E B O X S U P P O RT
C ATA L O G
NUMBER
978
A56
Adjust-A-BraceTM Application
Adjust-A-BraceTM is used to
mount electrical outlet boxes
between studs
ADJUST-A-BRACETM
985
Adjust-A-BraceTM
Product Features
Time saver for the installer
One brace will handle different
types and depths of boxes
4" or 4-11/16"
Gives the freedom to choose
the location
No preset locations
Ruler marks are stamped on
the brace for consistent outlet
box placement every time
Old Work Saddle Application
The Old Work Saddle #970 is
designed to be used with 2-1/2"
deep switch boxes that have
plaster ears
TM
Application:
GRIP-LOK
Old
Work Saddle
Product
Feature
O R D E R I N G I N F O R M AT I O N - D I M E N S I O N S
A D J U S T - A - B R A C E TM O U T L E T B O X S U P P O R T
C ATA L O G
NUMBER
Compliances
DESCRIPTION
S T D.
PKG.
985
25
986
25
UPC
BAR CODE
DESCRIPTION
S T D.
PKG.
970RAC
10
UPC
BAR CODE
G R I P - L O K TM O L D W O R K S W I T C H B O X S U P P O R T
C ATA L O G
NUMBER
DESCRIPTION
S T D.
PKG.
UPC
BAR CODE
977
S u p p l i e d a s a p a i r. U s e p a i r t o m o u n t s w i t c h b o x
with plaster ears in hollow wall, 1-7/8 long legs
100 pairs
8977
S u p p l i e d a s a p a i r. U s e p a i r t o m o u n t s w i t c h b o x
with plaster ears in hollow wall, 1-7/8 long legs
100 pairs
8977-5
S u p p l i e d a s a p a i r. U s e p a i r t o m o u n t s w i t c h b o x
with plaster ears in hollow wall, 1-7/8 long legs
100 pairs*
GRIP-LOK TM
977, 8977, 8977-5
970RAC
*4 Bundles of 25
SWITCH BOX ACCESSORIES
C ATA L O G
NUMBER
DESCRIPTION
FOR RACO
SWITCH BOXES
S T D.
PKG.
961
100
962
100
963
100
964
O l d Wo r k G r i p t i t e C l i p
w/screws
523
100
966
O l d Wo r k Ti g e r g r i p C l i p
w/screws
100
UPC
BAR CODE
A57
Grounding Applications
982, 994
#14 WIRE
NEW
996, 8996-1
8983-1, 983
#12 WIRE
NEW
984, 997
#14 WIRE
NEW
992
#14 WIRE
998,
8998-1
993
#12 WIRE
NEW
973,
8973-1
975,
8975-1
O R D E R I N G I N F O R M AT I O N - D I M E N S I O N S
G R O U N D I N G P I G TA I L S
C ATA L O G
NUMBER
WIRE LENGTH
6"
8"
DESCRIPTION
S T D.
PKG.
UPC
BAR
CODE
982
994
# 1 4 S o l i d i n s u l at e d c o p p e r w i r e , c a p t i v e 4 - w a y c o m b o
h e a d g r e e n d y e f i n i s h gr o u n d s c r e w o n e e n d ( 2 5 p c . b u n d l e s )
1000
983
996
# 1 2 S o l i d i n s u l at e d c o p p e r w i r e , c a p t i v e 4 - w a y c o m b o
h e a d g r e e n d y e f i n i s h gr o u n d s c r e w o n e e n d ( 2 5 p c . b u n d l e s )
1000
8983-1
# 1 2 S o l i d i n s u l at e d c o p p e r w i r e , c a p t i v e 4 - w a y c o m b o h e a d
8 9 9 6 - 1 g r e e n d y e f i n i s h gr o u n d s c r e w o n e e n d , p o l y b a g
( 1 0 p c s p e r p o ly b a g )
984
997
1000
992
# 1 4 S t r a n d e d i n s u l at e d c o p p e r w i r e , c a p t i v e 4 - w a y
c o m b o h e a d g r e e n d y e f i n i s h gr o u n d s c r e w o n e e n d ,
spade terminal one end (100 pc. bundles)
500
993
# 1 2 S t r a n d e d i n s u l at e d c o p p e r w i r e , c a p t i v e 4 - w a y
c o m b o h e a d g r e e n d y e f i n i s h gr o u n d s c r e w o n e e n d ,
spade terminal one end (100 pc. bundles)
500
40 bags*
DESCRIPTION
S T D.
PKG.
998
4 - Wa y c o m b o h e a d gr e e n d y e f i n i s h gr o u n d s c r e w f o r 1 0 - 3 2
t a p p e d h o l e , c l a m s h e l l p a c k ag e ( 1 0 0 p c s p e r c l a m s h e l l )
1000
8998-1
4 - Wa y c o m b o h e a d gr e e n d y e f i n i s h gr o u n d s c r e w f o r 1 0 - 3 2
tapped hole, poly bag (10 pcs. per bag)
50 bags*
973
S l o t t e d h e a d gr e e n d y e f i n i s h gr o u n d s c r e w f o r 1 0 - 3 2 t a p p e d
h o l e , c l a m s h e l l p a c k ag e ( 1 0 0 p c s p e r c l a m s h e l l )
1000
8973-1
S l o t t e d h e a d gr e e n d y e f i n i s h gr o u n d s c r e w f o r 1 0 - 3 2 t a p p e d
hole, poly bag (10 pcs. per bag)
50 bags*
975
G r e e n d y e f i n i s h gr o u n d c l i p f o r # 1 4 - # 1 0 AW G c o p p e r,
c l a m s h e l l p a c k ag e ( 1 0 0 p c s p e r c l a m s h e l l )
1000
8975-1
G r e e n d y e f i n i s h gr o u n d c l i p f o r # 1 4 - # 1 0 AW G c o p p e r, p o l y b a g
(10 pcs. per bag)
50 bags*
* O r d e r s t a n d a r d p a c k ag e b a g q u a n t i t i e s o n ly, n o t p e r p i e c e
UPC
BAR
CODE
A58
Add-A-Depth Applications
Add-A-Depth ring or goof-ring
is designed to act as a barrier
between combustible wall surfaces
and the wiring system
For single and two-gang device
boxes
There is no UL standard for this
product
Subject to acceptance by an
electric inspector
The NEC Code States:
370-20. in Wall or Ceiling
In walls or ceilings of concrete,
tile, or other non-combustible
material, boxes shall be installed
so that the front edge of the box
will not set back of the finished
surface more than 1/4 inch
(6.35 mm). In walls and ceilings
constructed of wood or other
combustible material, boxes shall
be flush with the finished surface
or project there from
Nailing Spur Applications
Protects nonmetallic sheathed
cable or raceway type wires running through wood studs, joists,
rafters or similar structural wood
members from accidental nail,
screw or drill penetration
No nails required
Compliance
2709,
2710
976
O R D E R I N G I N F O R M AT I O N - D I M E N S I O N S
ADD-A-DEPTH RING EXTENDS SWITCH BOX SET TOO DEEP IN WALL
C ATA L O G
NUMBER
DESCRIPTION
A d j u s t m e n t r a n g e 1/ 4 " - 1 "
Tw o 1 - 1 / 8 " s c r e w s i n c l u d e d
976
S T D.
PKG.
UPC
BAR CODE
25
CABLE PROTECTOR
C ATA L O G
NUMBER
DESCRIPTION
S T D.
PKG.
2709
100
2710
200
UPC
BAR CODE
A59
Applications
904
903
905
O R D E R I N G I N F O R M AT I O N - D I M E N S I O N S
Internal/Insert Pad
Product Features
ING
COM ON
SO
ING
COM ON
SO
ING
COM ON
O
S
Compliance
DESCRIPTION
PA D
SIZE
F U L L PA D
VOLUME
CU. IN.
S T D.
PKG.
903
Each pad for (1) 4" box, (2) 4" x 2" boxes
or (2) 3" x 2" boxes
4" x 4"
3.5
20
904
E a c h p a d f o r 3 " x 2 " s w i t c h b o x o n ly
3 x 2"
1.8
20
UPC
BAR
CODE
DESCRIPTION
PA D
SIZE
S T D.
PKG.
905
7" x 6"
20
UPC
BAR
CODE
A60
S U R FA C E M O U N T B O X E S
4" SQUARE, 4-11/16" SQUARE, HANDY BOXES
ING
COM ON
SO
Applications
RACO Surface Mount Boxes are
specifically designed for exposed
work, flush mount applications
where an alternative to conduit
grounding is required
Boxes are installed on walls or
ceilings to support lighting fixtures,
switches or receptacles
Square boxes are used where
multiple conductor runs are split
into two or more directions
to bring power to a number
of electrical devices
Handy boxes are used to house
wiring devices such as switches
or outlets and as small
junction boxes
Product Features
Raised ground screw emboss on
bottom of box eliminates ground
screw/surface interference when
mounted on flat surface
All RACO Surface Mount Boxes
include a pre-assembled 3-way
ground screw and 8 long, #12
stranded pigtail saving both time
and labor for the installer
Compliance
189SM
191SM
192SM
232SM
650SM
660SM
663SM
670SM
257SM
258SM
O R D E R I N G I N F O R M AT I O N - D I M E N S I O N S
MASONRY BOXES 2-1/2" DEEP NONGANGABLE
WITH CONDUIT KOS
C ATA L O G
NUMBER
KNOCKOUTS
DESCRIPTION DEPTH
S I D E S C O N D. B OT T O M C O N D.
CU.
IN.
S T D.
PKG.
189SM
We l d e d
21.0
50
191SM
Drawn
1-1/2"
1-1/2", 3-3/4"
21.0
50
192SM
Drawn
21.0
50
232SM
We l d e d
30.3
25
CU.
IN.
S T D.
PKG.
50
8-3/4"
UPC
BAR
CODE
KNOCKOUTS
DESCRIPTION DEPTH
SIDES
C O N D.
File E195978
ENDS
C O N D.
B OT T O M
C O N D.
650SM
We l d e d
1-1/2"
6-1/2"
2-1/2"
2-1/2"
11.5
660SM
Drawn
1-7/8"
6-1/2"
2-1/2"
2-1/2"
13.0
50
663SM
Drawn
1-7/8" 4-3/4"
2-3/4"
1-3/4"
13.0
50
670SM
We l d e d
2-1/8" 6-1/2"
2-1/2"
2-1/2"
16.5
50
CU.
IN.
S T D.
PKG.
UPC
BAR
CODE
C ATA L O G
NUMBER
DESCRIPTION
189SM
We l d e d
21.0
50
257SM
We l d e d
2 - 1 / 8 " 2 - 1 / 2 ",1 0 - T K O
1-1/2", 1-3/4"
2-TKO
42.0
25
258SM
We l d e d
2-1/8" 8-1"
2-1/2", 2-3/4"
42.0
25
DEPTH
S I D E S C O N D. B OT T O M C O N D.
UPC
BAR