General procedure for making good


resin-socketed termination on
stranded wire ropes
Prepared by the
Health and Safety Laboratory
for the Health and Safety Executive

OFFSHORE TECHNOLOGY REPORT

Health Safety
Executive

General procedure for making good


termination on
stranded wire ropes
Health and Safety Laboratory
Broad Lane
Sheffield
S3 7HQ

HSE BOOKS

Crown copyright 2000


Applications for reproduction should be made in writing to:
Copyright Unit, Her Majesty's Stationery Office,
St Clements House, 2- l6 Colegate, Norwich NR3 1 BQ
First published 2000

All rights reserved. No part of this publication may be


reproduced, stored in a retrieval system, or transmitted
in any form or by any means (electronic, mechanical,
photocopying, recording or otherwise) without the prior
written permission of the copyright owner.

This report is made available by the Health and Safety


Executive as part of a series of reports of work which has
been supported by funds provided by the Executive.
Neither the Executive, nor the contractors concerned
assume any liability for the reports nor do they
necessarily reflect the views or policy of the Executive.

Summary

There have been a number of incidents in recent years involving the failure of resin-socketed
wire rope terminations (commonly known as resin cappings) on cables which were being used
for mooring floating offshore installations. Subsequent investigation by
Offshore
Safety Division (OSD) involved the making up of factory assembled samples, under
controlled conditions, which were failing at loads of up to 50% below the specified breaking
load limit for the ropes. These samples were made up by two different manufacturers who
utilised their normal procedures and site personnel. Since tethered offshore installations are
becoming more prevalent, OSD are concerned about the integrity of resin-terminated sockets,
particularly as regards the procedures used in their production and where these are made up in
the hazardous offshore environment.
0bjectives

HSL have carried out a research project intended to identify the main parameters that affect
the integrity of a resin-socketed terminations for 76 mm diameter stranded mooring rope
which is typically used for this type of application (this is the diameter of the ropes that failed)
and additionally to investigate whether size effects have a significant influence on the integrity of this diameter of rope termination. Part of this project was to produce and validate a
reliable procedure for producing good resin-socketed terminations on stranded wire ropes of
the size typically used for mooring offshore installations.
Main Findings

The procedure contained in this document is the result of that work and is produced here
the main report so that it can be more widely distributed.
separately
This procedure should be able to be followed by a semi-skilled operator given suitable training and who has demonstrated competence in this area.

HEALTH AND SAFETY LABORATORY


An agency of the Health and Safety Executive

iii

Contents

1.EQUlPMENTLlST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
2. PREPARING THE ROPE AND SOCKET . . . . . . . . . . . . . . . . . . . 1
3. PREPARING AND CLEANING THE BRUSH . . . . . . . . . . . . . . . . 2
4 POSITIONING AND ALIGNING THE BRUSH AND
SOCKET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
5 MIXING AND POURING THE RESIN . . . . . . . . . . . . . . . . . . . . . . . . 4
6 DISMANTLING THE CLAMPS AND SERVINGS . . . . . . . . . . . . . 5

HEALTH AND SAFETY LABORATORY


An agency of the Health and Safety Executive

l.

EQUIPMENT LIST

The following is a list of equipment and materials needed in order produce a resin-socketed
termination of a wire rope:
Wire rope
Wire rope socket
Rope socket rig and fittings
Rope
'disc
Steel tube for rope strands
Steel tube for rope wires
Split sleeve for centralising rope in socket
(for big ropes only)
Serving
Reel of soft iron serving wire (diameter of wire to match rope size)
Socket alignment tool
Plastic sheet
Rubber
ring
High pressure steam cleaner with water soluble detergent
Wirelock resin kit/s - volume to match conical bore of rope socket, including silicone grease,
stirrer and plasticine
Workshop hand tools including prybars,and tubes to fit strands and wires
Standard workshop protective clothing
2.

PREPARING THE ROPE AND SOCKET

Uncoil new rope from drum.


Identify and mark the cutting point.
Support the rope horizontally between two rope vices or similar so that the cutting point is
midway between the vices and the rope does not sag. Remove any excess rope dressing from
the part of the rope to be served.
Using the serving mallet, apply two soft iron servings, one at each side of the cutting point, as
shown in Figure 1. The length of these two servings must be at least equal to the rope diameter. The gap between the two servings must be just wide enough to allow the rope to be cut
without disturbing the two servings.
Apply one long serving at the side of the rope to be brushed. The length of this serving must
be at least 3 times the rope diameter and must be applied at a distance equal to the length of
the rope socket basket, minus half the rope diameter, measured from the cutting point. Prior
t o this serving, short lengths of plasticine must be applied in the valleys between the strands,
Figure 2, over a distance of approximately the rope diameter and half the diameter from the
end of this serving nearest to the cutting point. This will seal the spaces/cavitiesbetween the
strands underneath the serving which will help to eliminate possible resin leakage during the
pouring process.
HEALTH AND SAFETY LABORATORY
An agency of the Health and Safely Executive

Temporary rope clamps can be fitted at each side of the cutting point prior to cutting. These
are normally used if single stranded serving wire is used.
Place the rope on the ground on "vee" block supports at each side of the cutting point. Cut the
rope squarely using a slitting disc or similar equipment, as shown in Figure 3. Flame cutting
must not be used as this is likely to affect the mechanical properties of the steel wires.
Remove rope clamps.
Examine the rope socket to ensure the interior of the socket is clean and free of dirt etc.
Roughness of the inside surface is not important provided that there are no obstructions to the
prevent the resin cone from bedding into the socket when a load is applied to the termination.
If the socket has been used previously then any resin adhering to the socket wall should be
removed. The taper bore of the socket must be concentric within the socket and, in particular,
the wall thickness should be the same all around the socket periphery. Physical damage or
non-concentricity of the socket can lead to failure of the termination under load. Such
sockets must never be used.
Secure the socket in position on the rope rig, Figure 4. The rope rig serves as a secure brushing bench and helps to eliminate the manual handling of heavy rope sockets. It also provides
accurate axial alignment between rope and socket and it can be elevated and locked vertically
to enable the casting to be carried out correctly. If a purpose made rope rig is not available, a
reliable method of accurately aligning the rope with the socket must be developed and used.
This alignment must be maintained during the casting process. If this is not done, the load in
the rope and in the socket will not be axial, the wires will be unevenly loaded and failure of
the termination may result.
Apply a light smearing of silicon compound, supplied with the resin kit, to the inside the rope
socket bore. This will help the resin cone to bed into the socket when a load is applied, essential for the termination to develop its full strength, and will also help the removal of the resin
cone if the socket is to be reused.
Apply plastic covering over the portion of rope to be threaded through socket. Secure it with
masking tape, Figure 5. This will prevent contamination of the socket bore when the rope is
threaded through the socket.
Push the "0" ring onto rope over plastic covering and slide it on the rope so that it will be
clear of the brushing. This "0"ring will later be used as a seal at the socket neck.
Thread the served end of the rope through the socket so that the end to be brushed is clear of
the socket. Fasten the rope to the rope rig using the clamps provided, Figure 6. Ensure that
the end clamp is positioned exactly at the point on the rope to which the wires will be
unlayed.

3.

PREPARING AND CLEANING THE BRUSH

Adjust the rig to the desired position for brushing. Brushing is best carried out with the rig set
at an angle most convenient to the ropeman.
HEALTH AND SAFETY LABORATORY
An agency of the Health and Safety Executive

Remove and discard the short serving on the end of the rope.
Using the large steel tube, unwind and open out each rope strand, in turn, to form a basic
brush as in Figure 7. A flat blade is used to prise out each strand from the cluster before the
tube is pushed on over the strand. Great care must be taken when carrying out this operation
as the strands are springy when they are bent back and any slippage or accidental release of
tube is a potential hazard to persons standing nearby.
Starting with the inner wire rope core, and using the small steel tube, gently ease out of lay
and unwind each individual wire, in turn, to form a complete brush. As the wires are opened
out they should be brushed with paraffin to remove
loosen the rope dressing, Figure 8.
Each wire must be unwound down to the serving whilst still retaining its helical shape. Do
not attempt to straighten the wires. Do not repeatedly bend wires to achieve their correct
position as this can seriously weaken them. Over bending, nicking, and twisting of the wires
must be avoided as this could later cause fatigue failure of the wires during service. The
finished brush, Figure 9, must be as concentric as possible and the wires must be as evenly
distributed as possible.
Adjust the rope rig so that the brush is pointing downwards to allow the cleaning fluids to
drain away. Cleaning fluid must not be allowed to penetrate down into the rope underneath
the long serving.
Using the high pressure steam cleaner, Figure 10, thoroughly clean the brush using the detergent spray. Finally clean the brush with pure water to rinse off the degreasing agent or detergent. Allow the clean brush to drip dry whilst it is still pointing downwards, Figure 11.
Carry out a visual check of the brush to ensure that the wires are clean and that no lubricant
or dressing is present on the brushed wires. Check that the rope dressing is visible under the
serving, Figure 12.
4

POSITIONING AND ALIGNING THE BRUSH AND SOCKET

Measure and mark on the serving a distance of half the rope diameter measured from the inner
end of the long serving, Figure 13. Discard the plastic covering which was previously placed
over rope.
Position the socket in the rope rig, using socket spacers if needed, to align the socket with the
rope clamps.
Undo the clamps on the rope rig and pull the brush into the socket so that the small end of the
socket is in line with the marking on the serving. Ensure that the ends of the brushed wires
protrude approximately 3 mm above the end of the big end of the socket. If all three servings
have been positioned accurately, everything should fit correctly, Figure 14. The objective is
to achieve a length of half the rope diameter inside the socket neck. This will ensure proper
support of the wires at the root of the brush and help to protect them from fatigue damage.
It is important to minimise the rotation of the socket to prevent the silicon from inside the
socket being scraped off onto the freshly cleaned wires.

HEALTH AND SAFETY LABORATORY


An agency of the Health and Safety Executive

Using the split sleeve, Figure 15, align the rope so that it is concentric inside the socket neck.
Further axial alignment of the rope will be given by the seating clamp positions on the rope
rig when the rope is reclamped.
Reclamp the rope on the rig ensuring all the clamps are tight. Remove the socket alignment
tool.
Slide the "0" ring into position so that it fills annular gap between the rope and the socket
neck, Figure 16.
Seal the neck of the socket by applying plasticine over the top of the

ring, Figure 17

Adjust the rope rig so that the rope socket is vertical, Figure 18.

MIXING AND POURING THE RESIN

Detailed information on the use of the resin kits can be found in the Wirelock Technical Data
Manual and in the information leaflet which accompanies each kit.
Consider the temperatures of the rope, socket and resin kit. Are they the same or is any of
these likely to be at a temperature below
Ideally, all components should be above this
temperature, if not then the use of accelerator packs may need to be considered. The easiest
way to use these is to ensure that all components are at the same temperature and to follow the
resin kit supplier's instructions. If there is any doubt as to the component temperatures, then
they should be measured. If low temperature casting of the resin is unavoidable, it is particularly important that the root of the brush has been properly cleaned and that the procedures for
mixing, stirring and pouring the resin are closely followed. It may be possible to use a
warmed socket on a cold rope and some users have produced successful cappings using this
technique. In this case it is important to warm the socket only to room temperature and not
beyond. Storing the socket for a period in a warm area is better than heating it artificially.
Use of a warmed socket reduces the need for accelerator (booster) packs.
Examine the resin kit to be used, Figure 19. Each kit consists of two containers one with
liquid resin and one with powder together with a stirrer, silicon grease release agent and
plasticine. These are supplied in an outer container which is used for mixing. Booster packs
are available separately and are sized to match to the volume of the resin kits. Check that the
resin kit is not out of date. Out of date kits must be discarded. Check that the colour of the
powder is off-white and the resin is free flowing. Kits can be added together to give the
required volume. Always use the full container contents, never use part container contents.
Wear eye protection and a dust mask for mixing the resin. Mix the liquid resin and powder in
the container supplied with the resin kit. Stir for approximately 2 minutes whilst checking the
and
one booster pack
viscosity and colour of the mixture. For temperatures between
and
two booster packs must be added. Booster packs
must be added and between
do not work below
Pour the mixture into the socket immediately, ensuring that the mixture is poured at one
position only, as in Figure 20. Any movement is likely to introduce unwanted air into the
HEALTH AND SAFETY LABORATORY
An agency of the Health and Safety Executive

mixture inside the socket. Fill the socket up until the level of the fluid is flush with the end of
the socket. Finally, using a straight piece of wire of similar tool, broddle the mixture inside
the socket basket to remove any trapped air, Figure 21. The socket may be topped up as
necessary as the resin settles. Any leakages must be stopped immediately by simply applying
further plasticine around the socket neck as necessary. At room temperature, gelling will
normally take place in approximately 15 to 20 minutes. The mixture will be fully set after
approximately 1 hour. At low temperatures the gelling and setting may take much longer and
full setting can take as long as 2 hours even when booster kits are used.
When the resin has hardened, using a sharp instrument, carry out a scratch test by scoring the
set resin in the end of the socket, Figure 22. This should leave a shallow scratch mark indicating the resin is fully set. The final colour of the resin is likely to be either bluish green, Figure
23, or sandy brown, Figure 24, depending on the temperatures reached during curing. A
sandy colour indicates a hotter cure than the bluish green colour.
6

DISMANTLING THE CLAMPS AND SERVINGS

Remove the plasticine and "0" ring from the socket neck. Examine the completed socket
termination for any defects.
Unwind the long serving wire and cut it off as close as possible to the end of the socket neck,
Figure 25.
Remove the plasticine from between the rope strands and scrape off any leaked resin
compound.
Finally relubricate the rope with rope dressing taking care to seal the neck of the socket.
Remove the completed socket termination from the rope rig.
When the rope is put into use, it is advisable to ensure that the resin cone has bedded into the
socket. Unless the cone pulls into the socket by a few millimetres, the resin cone may not be
subjected to the compressive forces which give the termination its strength. The use of
release agent will help the cone to bed into the socket.

HEALTH AND SAFETY LABORATORY


An agency of the Health and Safety Executive

HEALTH AND SAFETY LABORATORY


An agency of the Health and Safety Executive

Printed and published by the Health and Safety Executive


C0.35 11/00

BOOKS
MAIL ORDER

HSE priced and free


publications are
available from:
HSE Books
PO Box 1999
Sudbury
Suffolk CO I0 2WA
Tel: 01787 881 l65
Fax: 0 1787 3 13995
Website: www.hsebooks.co.uk
RETAIL

HSE priced publications


are available from
good booksellers
HEALTH AND SAFETY ENQUIRIES

HSE InfoLine
Tel: 08701 545500
e-mail: hseinformationservices@natbrit.com
OTO 2000/068