Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 1

PROCESS CALCULATION

Regulator
Calculation
for IRCD
of Chemical Injection Skid
Calculation Title: Regulator Valve Calculation
for Chemical
Injection
Skid

Client:

LAMSON JOC

Project:

PROVISION OF THANG LONG


CHEMICAL INJECTION SKID

Calculation No.:

OGPE-CS-PCV-XXXX

Sheet No.:

of

REGULATOR CALCULATION
1

Tag No.:

PCV-66042/46/52/56/62/66/72/76/82/86/92/96

P&ID No.:

CISP-ZZZZ-2AAP-D01-0072

FLUID PROPERTIES

Calculation Standard

Case

Flowrate

Service:

Pour Point Despressant (liquid)

According to Masoneilan Calculation Method

Case 1 (Minimum Flowrate)

Case 2 (Normal Flowrate)

Case 3 (Maximum Flowrate)

litre/hr

0.16

4.33

8.5

kg/hr

0.1456

3.9403

7.735

kPaa

Vapor Pres of Liquid at Flowing Temp

Pv

Specific Gravity at Flowing Temp

Gf

10

Liquid Density

kg/m3

910

910

910

11

Liquid Viscosity

cP

59.15

59.15

59.15

12

Source Pressure

P1

kPag

4619

4619

4619

13

Source Temperature

T1

40

40

40

14

Sink Pressure

P2

kPag

4037

4037

4037

H1

PH1

kPa

H2

PH2

kPa

17.836

17.836

17.836

15
16
17
18

Upstream Static Head

Downstream Static Head

4.4

4.4

4.4

0.91

0.91

0.91

19

Differential Pressure

P1 - P2

kPag

582

582

582

20

Differential Static Head

PH1 + PH2

kPag

17.836

17.836

17.836

200

21
22

FRICTION LOSS CALCULATION

23

Upstream

24

Piping and Fitting

kPa

200

200

25

Other

kPa

26

Upstream Friction Loss

kPa

200

200

200

150

27

W1

Downstream

28

Piping and Fitting

kPa

150

150

29

Other

kPa

30

Downstream Friction Loss

kPa

150

150

150

kPa

350

350

350

31

W2

Total Friction Loss

32
33

SIZING DATA

34

Critical Flow Factor

0.75

0.75

0.75

35

Control Valve Inlet Pressure

P3

kPag

4419

4419

4419

36

Control Valve Outlet Pressure

P4

kPag

4204.836

4204.836

4204.836

37

Pressure Drop

kPa

214.164

214.164

214.164

(Note 2) Ps

kPa

4414.6

4414.6

4414.6

kPa

2483.2125

2483.2125

2483.2125

The Flow is Subcritical

The Flow is Subcritical

The Flow is Subcritical

0.000121

0.003274

0.006427

(Note 1) Cf

38

Cf2Ps

39
40
41

Valve Sizing Coefficient

42

Notes:

Cv

1. The Cf of 0.75 is chosen in this stage because that number is in the middle of the full range of C f. One the Cv and manufacturer are detimined,

43

we can enter the correct Cf value.

44

2. When Pv < 0.5 P1, Ps = P1 - Pv

45
46

A
Rev.

29-Mar-12
Date

Issued For Review


Description

Originated

Checked

Approved

Client

You might also like