Professional Documents
Culture Documents
Regulator For Thanglong
Regulator For Thanglong
Regulator
Calculation
for IRCD
of Chemical Injection Skid
Calculation Title: Regulator Valve Calculation
for Chemical
Injection
Skid
Client:
LAMSON JOC
Project:
Calculation No.:
OGPE-CS-PCV-XXXX
Sheet No.:
of
REGULATOR CALCULATION
1
Tag No.:
PCV-66042/46/52/56/62/66/72/76/82/86/92/96
P&ID No.:
CISP-ZZZZ-2AAP-D01-0072
FLUID PROPERTIES
Calculation Standard
Case
Flowrate
Service:
litre/hr
0.16
4.33
8.5
kg/hr
0.1456
3.9403
7.735
kPaa
Pv
Gf
10
Liquid Density
kg/m3
910
910
910
11
Liquid Viscosity
cP
59.15
59.15
59.15
12
Source Pressure
P1
kPag
4619
4619
4619
13
Source Temperature
T1
40
40
40
14
Sink Pressure
P2
kPag
4037
4037
4037
H1
PH1
kPa
H2
PH2
kPa
17.836
17.836
17.836
15
16
17
18
4.4
4.4
4.4
0.91
0.91
0.91
19
Differential Pressure
P1 - P2
kPag
582
582
582
20
PH1 + PH2
kPag
17.836
17.836
17.836
200
21
22
23
Upstream
24
kPa
200
200
25
Other
kPa
26
kPa
200
200
200
150
27
W1
Downstream
28
kPa
150
150
29
Other
kPa
30
kPa
150
150
150
kPa
350
350
350
31
W2
32
33
SIZING DATA
34
0.75
0.75
0.75
35
P3
kPag
4419
4419
4419
36
P4
kPag
4204.836
4204.836
4204.836
37
Pressure Drop
kPa
214.164
214.164
214.164
(Note 2) Ps
kPa
4414.6
4414.6
4414.6
kPa
2483.2125
2483.2125
2483.2125
0.000121
0.003274
0.006427
(Note 1) Cf
38
Cf2Ps
39
40
41
42
Notes:
Cv
1. The Cf of 0.75 is chosen in this stage because that number is in the middle of the full range of C f. One the Cv and manufacturer are detimined,
43
44
45
46
A
Rev.
29-Mar-12
Date
Originated
Checked
Approved
Client