Professional Documents
Culture Documents
ABL8RPM24200 Pre and Post Test Repair WIP: Model Defect/Symptom No. of Units
ABL8RPM24200 Pre and Post Test Repair WIP: Model Defect/Symptom No. of Units
ABL8RPM24200
Defect/Symptom
Iout Failure
For verification
Verified
No test slip
Vout 28.8 Failure
Hipot
Hard Trouble
Total
No. Of Units
89
41
28
26
8
7
4
203
Iout Failure
For verification
Verified
No test
Percent Contribution
44%
20%
14%
13%
4%
3%
2%
Pareto
44%
64%
78%
91%
95%
98%
100%
verification
Verified
No test slip
Hipot
Hard Trouble
Remarks
Iout 25A error
red-orange (22 units) /flicker (6units)
busted capacitor C73
Burned units
Hipot
Hard Trouble
Action
debugged the tester
for bench test
for analysis
for bench verification
repaired
for analysis
for scrap