PROJECT: CADANGAN MEMBINA DAN MENYIAPKAN SEKOLAH

MENENGAH KEBANGSAAN PADANG BEREMPAH YANG


MENGANDUNGI 24 BILIK DARJAH DI DAERAH SIPITANG, SABAH.
SAMPLE CALCULATION FOR LINE MHA1-MHA2
AVERAGE DRY WEATHER FLOW (ADWF)

0.23

m3/c/day

DESIGN FLOW (4 x ADWF)

1.13

m3/c/day

NO. OF POPULATION EQUIVALENT

154

THEREFORE, TOTAL DISCHARGE ( Q-REQUIRED)

174.41
0.12
0.0020

SIZE OF VC PIPE

225

mm

R = A/P = D/4

56.25

mm

S = 1 : 150

0.0067

MANNING COEFFICIENT, N

0.0120

V = (D/4)^2/3*(S)^1/2*(1/N)

A = (PI*D^2)/4

0.04

THEREFORE, DESIGNED CAPACITY (Q-DESIGN)


Q=VxA

0.04
2.38
3,432

pe
m3/day
m3/min.
m3/sec

1.00 m/sec
ok min.
0.80
m/sec
ok max. 4
m/sec
m2

m3/sec
m3/min
m3/day

CONCLUSION:
Q-REQUIRED < Q-DESIGN ( CONDITIONS OK)
225mm diameter VC pipe adopted is OK as the carrying capacity is far in excess
of the peak flow.