Professional Documents
Culture Documents
Step by Step: Street Lighting Simulation With Osram Leds in Dialux
Step by Step: Street Lighting Simulation With Osram Leds in Dialux
Agenda
Page
12
20
www.DIAL.de or www.dialux.com
Online Update
If you have already installed old version of DIALux, you could use online update to
newest version.
In DIALux you will find a new menu named Online.
After selecting Online Update DIALux automatically checks for newer versions of the
software and for new online PlugIns.
But it will take some time to finish update.
Project manager
with Inspector
Task Pane
Agenda
Page
12
20
Agenda
Page
12
20
This wizard guides you through the quick planning for streets.
Street profile
Street name and maintenance factor are likewise inserted on this page.
In the following window you can fix the individual or combined valuation
fields for the street. In order to define photometric requirements for the
street, select an illumination class for every valuation field.
Event / Title | December 17, 2008 | Page 13
SSL | Application Design Center Asia | V.Chen
Luminaire arrangement
In the window Luminaire arrangement you can select a luminaire and place this
in an arrangement. (You need to import the IES file of OSRAM LEDs first,
otherwise you can only select the existing traditional luminaire in DIALux)
You can optimize the arrangement parameters depending on the predefined
photometric requirements.
Event / Title | December 17, 2008 | Page 14
SSL | Application Design Center Asia | V.Chen
Start Calculation
Afterwards a final dialogue will appear automatically. If you activate the checkbox, the generated
street will be calculated immediately.
Click on the Finish button and your street project will be displayed.
Rotate 3D View
Agenda
Page
12
20
4. Coating material
No need of secondary
optical design
Lighting Class
Road information
Uniformity
Luminaire arrangement
will be decided based on
street profile
requirements
Figure
Single row
Double row,
with offset
Double row,
opposing
W 6m
N 2
W 8m
N 2
W 16m
N 4
0.4~0.5
0.5~0.8
0.5~0.8
Rules
of
thumb
Boom Length
Boom Angle
Mounting Height
(5)Pole Distance
Lamp
Emin(lx)
8.6
Emax(lx)
24
Uo
0.52
Emin/Emax
0.36
Not so uniform,
need to be improved
Optimized results
Eav(lx)
19
Emin(lx)
16
Emax(lx)
22
Uo
0.83
Emin/Emax
0.72
Table (E)
Eav(lx)
19
Emin(lx)
16
Emax(lx)
22
Uo
0.83
Emin/Emax
0.72
Main results