Design Brief Template
Design Brief Template
Batch 29 Group 2
EE10
BASE
MS15
25
GOLD
ELECTRICAL
LIGHTING LEVELS
COST
IMPLICATI
ON
RM
250,000
Base Building design office luminance level is designed to be around 500 Lux
as per IES/CIBSE recommendation.
2 MS1512 Design
In accordance to MS1525 Clause 6.2.2 (Table 13), the illuminance level for
building is designed to the maintained levels of 300 to 400 Lux
(recommended for general building areas and office). Maximum permissible
Lighting Power Density is 15W/m2 as per MS1525 Clause 6.3 (Table 14).
3 Gold Design
4 Summary of Scoring
Points Score in
Criteria
Summary of
Costing
Base Line
MS1525
Gold
RM750,000.00
RM550,000.00
RM781,200.00
5 Objective
Office
Space
Fitting Selection
MS1525
T8 fitting c/w
magnetic
ballast
Gold
TL5 fitting c/w high
frequency electronic
ballast and auto
dimmer function
Minimum Required
Luminance (Lux)
MS1525
300-400
Gold
300
As for a gold building, the office lighting should not be over designed, therefore the
introduction of the LuxSense Automatic dimmer for all fittings to ensure control of
the lux levels within the 300 Lux range.
(Refer to Supporting documents for Gold Building Typical office floor
design simulation)
8 Cost Implication
9 Supporting Documents