Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 2

Lab:

Specific heat capacity


Part A
Cold water
Hot water
Mixed water

Temperature
24 C
71 C
46 C

mcT + mcT= 0
(.1) (4180) (T2 24) + (.1) (4180) (T2 71) = 0
(4180) (T2 24) + (418) (T2 71) = 0
(418) T2 10032 + (418) T2 29678 = 0
(836) T2 39710 = 0
(836) T2 = 39710
T2 = 45.5C
%difference = measured value calculated value
100%
measured value
%difference = 46 45.5 100%
46
= .01 100%
= .1%
Part B
Mass (kg)
Initial (C)
Final (C)

Brass
.1
101
30

Water
.1
24
30

mcT + mcT= 0
(.1) (c) (30-101) + (.1) (4180) (30 24) = 0
(.1) (c) (-71) + (.1) (4180) (6) = 0
(-7.1) (c) + 2508 = 0
(-7.1) (c) = -2508
c = 353.239466 3.5 102 J/(kg . C)
The accepted value for the specific heat capacity
of brass is 3.8 102 J/(kg . C)
%error = accepted value measured value 100%
accepted value
%error = 380 350 100%
380
= 7.9%

Mass (kg)
Initial (C)
Final (C)

Mystery Metal
.2
100
35

Water
.1
23
35

mcT + mcT= 0
(.2) (c) (35 - 100) + (.1) (4180) (35 - 23) = 0
(.2) (c) (- 65) + (.1) (4180) (12) = 0
(- 13) (c) + 5016 = 0
(- 13) (c) = -5016
c = 380.846153 3.9 102 J/(kg . C)