Identification system for power stations (KKS)

KKS Seminar
solutions

page

Identification system for power stations (KKS)


Example 1:
Identification of a pump in a process-related system:
Breakdown level:
Process-related
identification:

Total plant

System code

Equipment unit code

Component
code

Example:

(sign)
unit A:

spray deluge system 20:

pump unit 001:

pump 01:

KKS:

= A

0 S G C 2

A P 0 0 1

K P 0 1

page

page 29

Identification system for power stations (KKS)


Example 2:
Identification of a drive motor of a spin gate in a structure:

Breakdown level:

Process-related
identification:
Example:
KKS:

Total plant

System code

Equipment unit code

Component
code

unit B

Steam turbine building,


floor 0 m

rolling door, isolating


elements, air locks

electrical
motor

= B

0 U M A 1

A B 0 0 1

- M 0 1

page 30

Identification system for power stations (KKS)


Example 3:
Identification of a fuse in a low voltage switchgear:
Breakdown level:

Process-related
identification:
Example:
KKS:
10

20

Total plant

System code

Equipment unit code

Component
code

overall

low voltage switchgear


< 1000 V:

switchgear equipment:

protective
device: (fuse)

0 A N A 3

G S 0 0 8

- F 0 1

30

page 31