Download as pdf
Download as pdf
You are on page 1of 7
HEATING, VENTILATING, AND AIR CONDITIONING SYMBOLS SUPPLY GRILLE OR REGISTER (9G, SR)! N ae CEILING EXHAUST, RETURN AND TRANSFER GRILLES AND REGISTERS (EG, ER, RG, RR, TG, TR) x CEILING DIFFUSERS (0) DIFFUSER BLANK VAY BOX |_| MITERED ELBOW WITH [%] TURNING VANES RADIUS ELBOW FIRE DAMPER FIRE/SMOKE DAMPER ‘SMOKE DAMPER. 3 s ‘COMBINATION DISCONNECT ‘AND MOTOR STARTER WEATHER PROOF COMBINATION [DISCONNECT AND MOTOR STARTER ‘VIBRATION ISOLATOR ‘AR FLOW QUANTITY: 200 SCFM PRESSURE AND TEMPERATURE TEST PLUG. POINT OF CONNECTION, RENOVATION POINT OF REMOVAL, DEMOLITION CEILING ACCESS DOOR PROVIDE DOOR UNDERCUT DOOR GRILLE PHOTO NUMBER AND DIRECTION IDENTIFIER FLEXIBLE CONNECTION (FC) FLEXIBLE DUCTWORK (SINGLE LINE) FLEXIBLE DUCTWORK (DOUBLE LINE) 4, RECTANGULAR DUCT 2 DIMENSIONS IN INCHES: 3. FIRST DIMENSION VISIBLE SIDE A GWENSONSIN INCHES 3. FIRST DIMENSION VISIBLE SIDE 2 SRENBONS N INCHES _] BALANCING DAMPER, 4. INTERNAL INSULATION'SOUND = seroma one T THATS 2 Socronengtons ero ane Ne a em = — INSIDE, TO INSIDE FACE OF LINER. _# 8. PROVISE LINING WHERE SOON, Sa OETOMIPER é aoie DESORBED INSPEC CATIONS 2 DUCTINSPECTION DOOR, T 4, EXISTING DUCTIEQUIPMENTTO REMAIN js HORTZONTAL OR VERTICAL) |. 1, DEMOLITION. EXISTING DUCTIEQUPMENT mre ETRE: Fe] ROW NORESTONOF A 1 TORRENS EXISTING EQUIPMENT, RELOCATED INDICATES DUCT MOUNTED CONTROL. DEVICE "X° SEE HVAC CONTROL SYMBOLS ‘SUPPLY OR INTAKE DUCT UP ‘SUPPLY OR INTAKE DUCT DOWN, \WITH INTEGRAL BALANCING DANPER, RETURN OR EXHAUST DUCT UP Ic a ieemne RETURN OR EXHAUST DUCT DOWN EQUIPMENT NOMENCLATURE MANUAL VALVES AND CHECK VALVES IDENTIFICATION ‘CONTROL VALVES IDENTIEICATION ——— 15-400 AD wave rvpe, se SPECIFICATIONS | vatve pesicnrion SZEOF WAVE ‘AIR OUTLET AND INLET IDENTIFICATION HVAC PIPING SYMBOLS DOUBLE LINE SINGLE LINE EXISTING PIPE (SGREENED) NEW PIPE EXISTING PIPE TO BE ABANDONED EXISTING PIPE TO BE REMOVED WELDED JOINT GROOVED END JOINT FLANGED JOINT FLEXIBLE COUPLING GROOVED END ADAPTER FLANGE STEEL BELLOWS, EXPANSION JOINT ELBOW UP ELBOW DOWN, TEE UP TEE DOWN LATERAL UP ‘CONCENTRIC REDUCER ECCENTRIC REDUCER UNION, ANCHOR —— PIPE ALIGNMENT GUIDE —~— ARBRE? HVAC CONTROLS SYMBOLS ® ier ae ¥ a ayy men DIVISION 16 MOTOR CONTROL CENTER MOTOR STARTER ELECTRIC MOTOR LOW-LIMIT FREEZE THERMOSTAT VARIABLE/ADJUSTABLE FREQUENCY DRIVE HVAC CONTROL PANEL (HCP) ‘SWITCH (OCCUPANCY SENSOR MOTOR CONTROL VALVE (2-WAY), (3:WAY) ‘TEMPERATURE SENSOR OR THERMOSTAT HUMIDITY SENSOR OR HUMIDISTAT EMERGENCY HVAC SHUTDOWN LIQUID FLOW SWITCH DUCT MOUNTED AIRFLOW MONITORING STATION ANALOG OUTPUT, INPUT: DATA POINT TO DDC DIGITAL OUTPUT, INPUT: DATA POINT TO DDC ‘CURRENT SENSOR DIFFERENTIAL PRESSURE SENSOR OR SWITCH STATIC PRESSURE SENSOR DUCT SMOKE DETECTOR (AREA SMOKE DETECTOR MOTORIZED DAMPER OR VALVE RELAY ‘SOLENOID VALVE @@as e FEE DO DIVISION 16 FIRE ALARM CONTROL PANEL LIQUID LINE PRESSURE SENSOR AND ‘SIGNAL TRANSMITTER: LIQUID FLOW INDICATING TRANSMITTER FLOW CONTROL VALVE TURBINE LIQUID FLOW METER VENTURI FLOW METER POSITIVE, NEGATIVE, NEUTRAL ROOM PRESSURIZATION FAN SPEED CONTROLLER ALARM LIGHT AND HORN STATION DDC ANALOG OUTPUT DDC DIGITAL OUTPUT DDC ANALOG INPUT DDC DIGITAL INPUT PIPING IDENTIFICATION — PsS— = STEAM, LOW PRESSURE — HPS—— STEAM, HIGH PRESSURE — s¢—— _ STEAM, CONDENSATE — cHS—— CHILLED WATER, SUPPLY — CHR—— CHILLED WATER, RETURN. — HwS—— HEATING WATER, SUPPLY — HWR—— _ HEATING WATER, RETURN — ¢D—— _ HVAC CONDENSATE DRAIN — cWSs—— CONDENSER WATER, SUPPLY — CWR— CONDENSER WATER, RETURN ABBREVIATIONS ACCU AIR COOLED CONDENSING UNIT ACU AIR CONDITIONING UNIT AHU AIR HANDLING UNIT AS ‘CENTRIFUGAL AIR SEPARATOR BD BALANCING DAMPER BDD —_-BACKDRAFT DAMPER (GRAVITY) BO BOILER cc ‘COOLING COIL CCU = CABINET GONVECTOR UNIT co ‘CEILING DIFFUSER CF ‘CEILING FAN CH ‘CABINET HEATER CMF CHEMICAL FEEDER CRU CONDENSATE RETURN UNIT CSU CEILING-MOUNTED AIR SUPPLY UNIT cu ‘CONDENSING UNIT EA EXHAUST AIR: EDH ELECTRIC DUCT HEATER cr EXHAUST FAN EG EXHAUST GRILLE ER EXHAUST REGISTER —T DIAPHRAGM EXPANSION TANK EUH ELECTRIC UNIT HEATER. Fo FLEXIBLE CONNECTION, FAIL CLOSE Fou FAN-COIL UNIT FD FIRE DAMPER Fo FAIL OPEN FF FINAL FILTER FRP FIBERGLASS REINFORCED PLASTIC FsD FIRE SMOKE DAMPER FT FINNED-TUBE BASEBOARD HEATER: FZ FREEZE STAT HC EATING COIL HCP (HVAC CONTROL PANEL HD ‘HOOD, EXHAUST HGR HOTGLYCOL RETURN GELARSBAS ARABIA ag*gagees 'HOT GLYCOL SUPPLY [HEAT TRANSFER PACKAGE HEATING AND VENTILATING UNIT (HEATING WATER PUMP [HEAT EXCHANGER INFRARED HEATERS LOUVERED PENTHOUSE (MAKEUP AIR UNIT (MDUNG BOX MOTORIZED DAMPER MOTORIZED LOUVER ‘OUTSIDE AIR ‘OUTSIDE AIR INTAKE, ‘OPPOSED-BLADE DAMPER (MANUAL) OPERATOR INTERFACE TERMINAL ‘OCCUPANCY SENSOR PRESSURE-CONTROL VALVE PREFILTER PREHEAT COIL PACKAGED TERMINAL AIR CONDITIONING UNIT PITOT-TUBE TESTING STATION RETURN AIR RETURN FAN RETURN GRILLE RADIANT GAS-FIRED HEATING SYSTEM REFRIGERANT LIQUID PIPE RETURN REGISTER REFRIGERANT SUCTION PIPE ‘SOUND ATTENUATOR, SUPPLY AIR ‘SUPPLY FAN SUPPLY GRILLE STATIC PRESSURE ‘SUPPLY REGISTER TERMINAL UNIT UNIT HEATER VARIABLE AIR VOLUME TERMINAL BOX, VARIABLE AIR VOLUME CEILING DIFFUSER

You might also like