HEATING, VENTILATING, AND AIR CONDITIONING SYMBOLS
SUPPLY GRILLE OR REGISTER (9G, SR)!
N ae
CEILING EXHAUST, RETURN AND TRANSFER GRILLES
AND REGISTERS (EG, ER, RG, RR, TG, TR)
x
CEILING DIFFUSERS (0) DIFFUSER BLANK
VAY BOX
|_| MITERED ELBOW WITH
[%] TURNING VANES
RADIUS ELBOW
FIRE DAMPER
FIRE/SMOKE DAMPER
‘SMOKE DAMPER.
3
s
‘COMBINATION DISCONNECT
‘AND MOTOR STARTER
WEATHER PROOF COMBINATION
[DISCONNECT AND MOTOR STARTER
‘VIBRATION ISOLATOR
‘AR FLOW QUANTITY: 200 SCFM
PRESSURE AND TEMPERATURE TEST PLUG.
POINT OF CONNECTION, RENOVATION
POINT OF REMOVAL, DEMOLITION
CEILING ACCESS DOOR
PROVIDE DOOR UNDERCUT
DOOR GRILLE
PHOTO NUMBER AND
DIRECTION IDENTIFIER
FLEXIBLE CONNECTION (FC)
FLEXIBLE DUCTWORK (SINGLE LINE)
FLEXIBLE DUCTWORK (DOUBLE LINE)
4, RECTANGULAR DUCT
2 DIMENSIONS IN INCHES:
3. FIRST DIMENSION VISIBLE SIDE
A GWENSONSIN INCHES
3. FIRST DIMENSION VISIBLE SIDE
2 SRENBONS N INCHES_] BALANCING DAMPER, 4. INTERNAL INSULATION'SOUND
= seroma one T THATS 2 Socronengtons ero ane Ne
a em = — INSIDE, TO INSIDE FACE OF LINER.
_# 8. PROVISE LINING WHERE SOON,
Sa OETOMIPER é aoie DESORBED INSPEC CATIONS
2 DUCTINSPECTION DOOR, T 4, EXISTING DUCTIEQUIPMENTTO REMAIN
js HORTZONTAL OR VERTICAL)
|. 1, DEMOLITION. EXISTING DUCTIEQUPMENT
mre ETRE:
Fe] ROW NORESTONOF A 1 TORRENS
EXISTING EQUIPMENT, RELOCATED
INDICATES DUCT MOUNTED CONTROL.
DEVICE "X° SEE HVAC CONTROL SYMBOLS
‘SUPPLY OR INTAKE DUCT UP
‘SUPPLY OR INTAKE DUCT DOWN,
\WITH INTEGRAL BALANCING DANPER, RETURN OR EXHAUST DUCT UP
Ic a ieemne RETURN OR EXHAUST DUCT DOWN
EQUIPMENT NOMENCLATURE
MANUAL VALVES AND CHECK VALVES IDENTIFICATION ‘CONTROL VALVES IDENTIEICATION
———
15-400
AD wave rvpe, se
SPECIFICATIONS
| vatve pesicnrion
SZEOF WAVE
‘AIR OUTLET AND INLET IDENTIFICATIONHVAC PIPING SYMBOLS
DOUBLE LINE SINGLE LINE
EXISTING PIPE (SGREENED)
NEW PIPE
EXISTING PIPE TO BE
ABANDONED
EXISTING PIPE TO BE REMOVED
WELDED JOINT
GROOVED END JOINT
FLANGED JOINT
FLEXIBLE COUPLING
GROOVED END
ADAPTER FLANGE
STEEL BELLOWS,
EXPANSION JOINT
ELBOW UP
ELBOW DOWN,
TEE UP
TEE DOWN
LATERAL UP
‘CONCENTRIC
REDUCER
ECCENTRIC REDUCER
UNION,
ANCHOR
—— PIPE ALIGNMENT GUIDE
—~— ARBRE?HVAC CONTROLS SYMBOLS
® ier
ae ¥
a
ayy men
DIVISION 16 MOTOR CONTROL CENTER
MOTOR STARTER
ELECTRIC MOTOR
LOW-LIMIT FREEZE THERMOSTAT
VARIABLE/ADJUSTABLE FREQUENCY DRIVE
HVAC CONTROL PANEL (HCP)
‘SWITCH
(OCCUPANCY SENSOR
MOTOR CONTROL VALVE (2-WAY), (3:WAY)
‘TEMPERATURE SENSOR OR THERMOSTAT
HUMIDITY SENSOR OR HUMIDISTAT
EMERGENCY HVAC SHUTDOWN
LIQUID FLOW SWITCH
DUCT MOUNTED AIRFLOW MONITORING STATION
ANALOG OUTPUT, INPUT: DATA POINT TO DDC
DIGITAL OUTPUT, INPUT: DATA POINT TO DDC
‘CURRENT SENSOR
DIFFERENTIAL PRESSURE SENSOR OR SWITCH
STATIC PRESSURE SENSOR
DUCT SMOKE DETECTOR
(AREA SMOKE DETECTOR
MOTORIZED DAMPER OR VALVE
RELAY
‘SOLENOID VALVE@@as
e
FEE DO
DIVISION 16 FIRE ALARM CONTROL PANEL
LIQUID LINE PRESSURE SENSOR AND
‘SIGNAL TRANSMITTER:
LIQUID FLOW INDICATING TRANSMITTER
FLOW CONTROL VALVE
TURBINE LIQUID FLOW METER
VENTURI FLOW METER
POSITIVE, NEGATIVE, NEUTRAL ROOM
PRESSURIZATION
FAN SPEED CONTROLLER
ALARM LIGHT AND HORN STATION
DDC ANALOG OUTPUT
DDC DIGITAL OUTPUT
DDC ANALOG INPUT
DDC DIGITAL INPUT
PIPING IDENTIFICATION
— PsS— = STEAM, LOW PRESSURE
— HPS—— STEAM, HIGH PRESSURE
— s¢—— _ STEAM, CONDENSATE
— cHS—— CHILLED WATER, SUPPLY
— CHR—— CHILLED WATER, RETURN.
— HwS—— HEATING WATER, SUPPLY
— HWR—— _ HEATING WATER, RETURN
— ¢D—— _ HVAC CONDENSATE DRAIN
— cWSs—— CONDENSER WATER, SUPPLY
— CWR— CONDENSER WATER, RETURNABBREVIATIONS
ACCU AIR COOLED CONDENSING UNIT
ACU AIR CONDITIONING UNIT
AHU AIR HANDLING UNIT
AS ‘CENTRIFUGAL AIR SEPARATOR
BD BALANCING DAMPER
BDD —_-BACKDRAFT DAMPER (GRAVITY)
BO BOILER
cc ‘COOLING COIL
CCU = CABINET GONVECTOR UNIT
co ‘CEILING DIFFUSER
CF ‘CEILING FAN
CH ‘CABINET HEATER
CMF CHEMICAL FEEDER
CRU CONDENSATE RETURN UNIT
CSU CEILING-MOUNTED AIR SUPPLY UNIT
cu ‘CONDENSING UNIT
EA EXHAUST AIR:
EDH ELECTRIC DUCT HEATER
cr EXHAUST FAN
EG EXHAUST GRILLE
ER EXHAUST REGISTER
—T DIAPHRAGM EXPANSION TANK
EUH ELECTRIC UNIT HEATER.
Fo FLEXIBLE CONNECTION, FAIL CLOSE
Fou FAN-COIL UNIT
FD FIRE DAMPER
Fo FAIL OPEN
FF FINAL FILTER
FRP FIBERGLASS REINFORCED PLASTIC
FsD FIRE SMOKE DAMPER
FT FINNED-TUBE BASEBOARD HEATER:
FZ FREEZE STAT
HC EATING COIL
HCP (HVAC CONTROL PANEL
HD ‘HOOD, EXHAUST
HGR HOTGLYCOL RETURNGELARSBAS ARABIA ag*gagees
'HOT GLYCOL SUPPLY
[HEAT TRANSFER PACKAGE
HEATING AND VENTILATING UNIT
(HEATING WATER PUMP
[HEAT EXCHANGER
INFRARED HEATERS
LOUVERED PENTHOUSE
(MAKEUP AIR UNIT
(MDUNG BOX
MOTORIZED DAMPER
MOTORIZED LOUVER
‘OUTSIDE AIR
‘OUTSIDE AIR INTAKE,
‘OPPOSED-BLADE DAMPER (MANUAL)
OPERATOR INTERFACE TERMINAL
‘OCCUPANCY SENSOR
PRESSURE-CONTROL VALVE
PREFILTER
PREHEAT COIL
PACKAGED TERMINAL
AIR CONDITIONING UNIT
PITOT-TUBE TESTING STATION
RETURN AIR
RETURN FAN
RETURN GRILLE
RADIANT GAS-FIRED HEATING SYSTEM
REFRIGERANT LIQUID PIPE
RETURN REGISTER
REFRIGERANT SUCTION PIPE
‘SOUND ATTENUATOR, SUPPLY AIR
‘SUPPLY FAN
SUPPLY GRILLE
STATIC PRESSURE
‘SUPPLY REGISTER
TERMINAL UNIT
UNIT HEATER
VARIABLE AIR VOLUME TERMINAL BOX,
VARIABLE AIR VOLUME
CEILING DIFFUSER