MODEL 4 R R 2

DIGIT

1 2 3 4

3000

T S K -

800

5,6,7 & 8

9 10 11 -

12,13,14

DIGIT1 COMPRESSOR FAMILY SERIES


EITHER A NUMBER OR LETTER ESTABLISHED
FOR EACH PRODUCT MODEL

DIGITS 12,13 & 14 BILL OF MATERIAL - PRODUCT VARIATIONS


100 = STD. COMP. USED IN COPELAND COND. UNITS.
200 = STD. COMP. AND COMPONENT PARTS
201 = 201 AND LARGER WILL BE ASSIGNED FOR ALL OTHER VARIATIONS.
800 = STD. REPLACEMENT COMPRESSOR AND COMPONENT. 240 VOLT CONTROL.
801 = STD. REPLACEMENT COMPRESSOR AND COMPONENT. 120 VOLT CONTROL.

DIGIT 2 COMPRESSOR TYPE


A = STANDARD AIR COOLED
D = DISCUS REFRIGERANT COOLED
R = STANDARD REFRIGERANT COOLED
T = TWO STAGE
W = STANDARD WATER COOLED
A DIGIT IN THIS POSITION (e.g. 44R3)
REPRESENTS THE COMPRESSOR FAMILY
SERIES AND INDICATES TANDEM
COMPRESSOR
DIGIT 3 DISPLACEMENT AND VALVE PLATE
A LETTER ONLY, ARBITRARILY ASSIGNED FOR
EACH DIFFERENT DISPLACEMENT VALVE
PLATE COMBINATION WITHIN ANY ONE FAMILY
SERIES

DIGIT 4 MODEL VARIATION


A NUMBER OR LETTER ASSIGNED TO
INDICATE MAJOR VARIATIONS WITHIN ANY
ONE FAMILY SERIES

DIGITS 5, 6 ,7, & 8 TYPICAL MOTOR RATING


DIGIT 8 IS ALSO USED FOR OIL IDENTIFIER
"E" = POLYOL ESTER, "L" = SHIPPED WITHOUT OIL
"A" = ALKYBENZENE
CODE
0033

NOMINAL HP
1/3

CODE
1000

NOMINAL HP
10

0050
0051
0075

1/2
1/2
3/4

1015
1200
1500

10
12
15

0100
0150

1
1-1/2

2000
2200

20
22

0200
0210

2
2
3

2500
2700

25
27
30

0300
0310
0311

3
3

3000
3500
4000

0400
0500

4
5

5000
6000

50
60

0505
0600
0750

5
6
7-1/2

7000
8000

TANDEM
70
80

0765
0900

7-1/2
9

1110
1120

100
120

DIGIT 11 TYPICAL ELECTRICAL CODES


CODE
A

60 Hz.
115-1

50 Hz.
100-1

CODE
R

B
C

230-1
208/230-3

200-1
200/220-3

S
T

D
E

460-3
575-3

380/420-3
500-3

U
V

F
G
H

208-1

115-1
230-1
200-1

W
X
Y

I
K

208/230/460-3

208/230-1
200/380/400-3

Z
3

200-1

4
5
6

100-1
200/230-3
230-3

100-1

230/460-3

210/240/380-3
380/420-3
200/400-3

7
8

383
200/220-380-3

346-3
200/346-3

L
M
N
O
P

ALL DC RATINGS
200/380-3

60 Hz.

220-1
200-1
200-3
208/230-1

TYPE PROTECTION

EXTERNAL INHERENT PROTECTION. ONE PROTECTOR, (LINE


BREAK). USE WITH CONTACTOR.

INTERNAL INHERENT PROTECTION. ONE PROTECTOR, (LINE


BREAK). USE WITH CONTACTOR.

INTERNAL THERMOSTAT(S) AND EXTERNAL SUPPLEMENTARY


PROTECTOR(S) MT'D ON COMPRESSOR, (TWO FOR 3 PH., ONE
FOR SINGLE PH.). USE WITH CONTACTOR.

INTERNAL THERMOSTAT(S) AND THREE EXTERNAL


SUPPLEMENTARY PROTECTORS MT'D ON COMPRESSOR. USE
WITH CONTACTOR.

INTERNAL THERMAL PROTECTION. ELECTRONIC SENSORS AND


CONTROL MODULE EXTERNAL. USE WITH CONTACTOR.

35
40

COMPRESSOR MOTOR TYPE


CODE
C

PHASE
1

DESCRIPTION
CAPACITOR RUN - CAPACITOR START

I
E

1
3

INDUCTION RUN - CAPACITOR START


WYE (STAR) DELTA

SIX LEAD PART WINDING OR ACROSS


THE LINE EXCEPT 575 VOLT

MISC. THREE PHASE


SINGLE VOLTAGE THREE LEAD
DUAL VOLTAGE NINE LEAD
575 VOLT 60 cy/500 VOLT 50 cy
UNDER 20 HP 3 LEAD, 20 HP
AND UP 6 LEAD PART WINDING

200/220-1

200/220-3
MISC. AC RATINGS
500-3

DIGIT 10 COMPRESSOR MOTOR PROTECTION


CODE

50 Hz.
200/240-3

220/240-1
200-1