Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

FS/VS

EKH
EKW

ELEVATION

VELUX Venting
Skylight (VS/VSE)

100 mm
3060 mm
VELUX Fixed
Skylight (FS)

Please note:
Skylights must be at a min. pitch of
15 degrees, and spaced 100mm apart
for the channel section of the EKH/EKW
combiflashing to fit correctly.
Due to the design of Pressed Metal Tile
roofing materials it is imperative that the
roof battens are rebated 25 mm around
the perimeter of the VELUX skylight, for
the EKH/EKW combi flashing, to maintain
aesthetics.

VELUX skylight with EKH


flashing, installed to manufacturers
installation instructions. Skylights
must have a min. pitch of 15 degrees

CROSS SECTION AA VS/VSEFS with EKH/EKW combi flashing

NEW ZEALAND LTD.


SkyProduct Management
VS/VSEVentilating Skylight/Electric
EKH/EKW combi flashing installed

0800 650 445


&

FSFixed

Name
Drawn by
Checked by
Drawing No.

Date
Jan. 08
Jan. 08

Skylight with

This drawing is an instrument of service and is provided for informational use only.
2006 VELUX GROUP

VELUX is a registered trademark

You might also like