2x2x16 GA. GALV.

ANGLE
SCREWED TO PANEL SKIN

ALIGN WITH FACE


OF COLUMN
(8" MIN.)

6"

#4 AT 9"o.c. - POST INSTALL WITH


EPOXY DOWELLING SYSTEM
WITH 4" EMBEDMENT OR CAST IN
PLACE WITH STANDARD HOOK.
DO NOT DOWEL INTO COLUMN
ISOLATION POCKETS. DO NOT
DOWELL STRUCTURAL BRACED
BAY CURBS INTO FREEZER
SLAB.

1'-6"

INSULATED METAL
WALL PANEL

2'-0"

See Curb Plan for Heights

(2) #4 CON'T.
9" REINFORCED
CONCRETE SLAB
BUTYL SEALANT
BRING PANEL JOINT CAULK
FLUSH TO FACE OF PANEL
SEALANT TAPE
6 MIL. POLY. SLIP
SHEET

PRE-FINISHED BASE TRIM


w/RUBBER WASHER AT 6"o.c.
HEAVY BEAD OF BUTYL
CAULK IN CORNER OF BASE
CHANNEL

RIGID INSULATION
(TWO LAYERS)

GALVANIZED BASE
CHANNEL
UNDERFLOOR
WARMING

SEALANT TAPE
45 MIL. VINYL VAPOR BARRIER
w/(2) CONT. BEADS OF BUTYL
SEALANT AT 12" OVERLAPPING
JOINTS. FULLY BOND TO FACE OF
BASE CHANNEL AND TO AMBIENT
SIDE OF SKIN METAL PANEL 2"
(MIN.) ABOVE BASE CHANNEL

3" CONCRETE
BEARING SLAB

1
A6.2

SCALE: 1 1/2" = 1'-0"


NOTE: REFER TO STRUCTURAL DRAWINGS
FOR CURB REINFORCING AT BRACED BAYS.