Desuperheater Flow Calculation

You might also like

Download as xls, pdf, or txt
Download as xls, pdf, or txt
You are on page 1of 1

DESUPERHEATER FLOW CALCULATION

Spray Water In
Flow (m1)
Pressure
Temperature
Enthalpy (H1)

#VALUE! Kg/hr
15
Bar a
45
Deg. C
#VALUE! KJ/Kg

Desuperheated Steam Out

Steam In
Flow (m2)
Pressure
Temperature
Enthalpy (H2)

#VALUE! Kg/hr
100
Bar a
50
Deg. C
#VALUE! KJ/Kg

DESUPERHEATER

Flow (m2)
Pressure
Temperature
Enthalpy (H2)

Flow (m)
Pressure
Temperature
Enthalpy (H)

3000
20
50
###

Kg/hr
Bar a
Deg. C
KJ/Kg

#VALUE! Kg/hr
20
Bar a
#VALUE! Deg. C
#VALUE! KJ/Kg

Project:
Note:
1. This excel has inbulit Steam Table. So, enable MACROS before u Client:
Consultant:
2. Give Input in Yellow Cells and get output in Green Cells.
Document:
Prepd By:
Doc. No.:

De-Superheater Flow Calculation


Chkd. By:

Appd. By:
Rev. No.:

Date: