Project : Worawuth's Residence, Bangkok

Unit No.

FC1-1
FC1-2
FC1-3
FC1-4
FC2-1
FC2-2
FC2-3
FC2-4
NOTES :

Location Served

Parlour Room
Living Room
Dining Room
Dining Room
Master Bed Room
Study Room
Bed Room 2
Bed Room 3

VRV-Fancoil

CAPACITY SCHEDULE FOR VRV FAN COIL UNIT

Q'ty

MATCHING UNIT CAPACITY

Set(s)

Total
Heat
Mbh.

Sensible
Heat
Mbh.

Supply
Air
Cfm.

Outdoor
Air
Cfm.

1
1
1
1
1
1
1
1

49.0
49.0
39.0
25.0
29.0
27.0
16.0
28.0

42
44
34
20
26
23
14
26

1,300
1,300
1,100
700
800
800
500
800

90
90
120
120
30
60
30
30

Entering Ext. Static


Air Temp. Pressure
Fdb./Fwb.
In.Wg.
76/64
76/64
77/64
77/64
76/64
76/64
76/64
76/64

1. Coil face velocity shall not exceed 450 Fpm.


2. Matching capacity shall be based on air entering condenser temperatuer of 95 Deg. F.
and satuated suction temperature of 35-45 Deg. F.
3. External static pressure exclude air filter pressure drop
4. Fan motor Hp. as shown are approximate.
5. Abbreviations for unit type :
- CPDD : Ceiling concealed w/return plenum & filter, Ducted type, Direct drive
- CSED/M : Ceiling suspended, Exposed type, Direct drive, Modify to duct type
- FSCD : Floor standing, Concealed type, Direct drive
- WMED : Wall mounted, Exposed type, Direct drive
6. Air conditioning unit should be Daikin or Mitsubishi

File : 274963739.xls

0.20
0.20
0.20
0.20

AIR HANDLER (FCU.)

Fan
Motor
Hp.

Power
Supply
V/Ph/Hz

Air
Handler
Type

1/15
1/15
1/15
1/20
1/15
1/15
1/20
1/15

220/1/50
220/1/50
220/1/50
220/1/50
220/1/50
220/1/50
220/1/50
220/1/50

4CCED
4CCED
4CCED
4CCED
CPDD
CPDD
CPDD
CPDD

Gas
Line
In.Dia.
3/
3/
3/
5/
5/
5/
5/
5/

4
4
4
8
8
8
8
8

PIPING
Liquid
Line
In.Dia.
3/
3/
3/
3/
3/
3/
3/
3/

8
8
8
8
8
8
8
8

Drain
Line
In.Dia.
1
1
1

3/
3/
3/
3/
3/

4
4
4
4
4

CDU.

Unit
Connection

Remark

CU-1
CU-2
CU-3
CU-2
CU-1
CU-3
CU-2
CU-3

- 4CCED : 4 Way, Ceiling Cassatte, Exposed type, Direct drive w/drain lift pump
- 2CCED : 2 Way, Ceiling Cassatte, Exposed type, Direct drive w/drain lift pump
- WMED : Wall mounted, Exposed type, Direct drive

Page : 1 of 2

Date : 06/30/2015

Project : Worawuth's Residence, Bangkok


FC. No.
FC1-1
FC1-2
FC1-3
FC1-4
FC2-1
FC2-2
FC2-3
FC2-4

Area Served

Parlour Room
Living Room
Dining Room
Dining Room
Master Bed Room
Study Room
Bed Room 2
Bed Room 3

Summary

Select Model
Maximum connected load
% Connected load

Cap.
49
49
39
25
29
27
16
28

262

Model

CU-1

125
125
100
63
80
80
50
80

125

703

205

2.70

80

CU-2
125
63
50

200
260
103

238
200
260
119

CU-3

CU-4

CU-5

CU-6

100
80
80

260
200
260
130

200
260
-

250
325
-

250
325
-

You might also like