Example A460-V, 25-hp, 60-Hz, four-pole, Y-connected wound-rotor induction motor has the following impedances in ohms per phase referred to the stator circuit R=06412 R=0.3320 X= 11060 ¥3= 0.464 Q Xe 26.3.2 |. What is the maximum torque of this motor? At what speed and slip does it occur? 2, What is the starting torque of this motor? 3. If the rotor resistance is doubled, what is the speed at which the maximum torque now occur? What is the new starting torque of the motor? 4. Calculate and plot the 7-s c/e for both cases. 255.2V Solution Be [Rig + (Xone + Xa =— 92 __ 9.108 40.590) + (1.106 + 0.4647 The corresponding speed is =S)Iy = = 0.198) x1800= 1444 pm Solution The torque at this speed is Af BE 20, | Ra + VR + Kru +X.) | 3x(255.2)° To S00 na lugs dG 2x (1800% Die 590 + (0.590) + (1.106 + 0.464)" | =229Nm Solution The starting torque can be found from the torque eqn. by substituting s = 1 R (8) s ) + (Xqy +X _ Wy Ry (Ray +R) + Xe # XY 1 3x(255.2)' (0.332) x{(0.590 + 0.332)? + (1.106 +0.464)*] Solution 3. If the rotor resistance is doubled, then the slip at maximum torque doubles too 0.396 Ste The corresponding speed is = (1-0,396)>1800 = 1087 rpm Ig = A= SW The maximum torque is stil Tuas = 229 'N.m Solution The starting torque is now r= 3x(255.2)' x (0.664) | : 1800% ar [(0.590 + 0.664)’ + (1.106 + 0.404)" ] =170 Nm