70Mhz 2 (4) Channel Digital Oscilloscope Hmo722 (Hmo724)
70Mhz 2 (4) Channel Digital Oscilloscope Hmo722 (Hmo724)
70Mhz 2 (4) Channel Digital Oscilloscope Hmo722 (Hmo724)
Component Tester/Bus
Signal Source
Ethernet/USB
Dual-Interface HO730
(Option)
R 2
GSa/s Real Time, Low Noise Flash A/D Converter
(Reference Class)
R 2MPts Memory, Memory
oom up to 50,000:1
R MSO (Mixed Signal Opt. HO3508) with 8 Logic Channels
R S
erial Bus Trigger and Hardware accelerated Decode
incl. List View. Options: I2C + SPI + UART/RS-232, CAN/LIN
R Automatic Search for User defined Events
R Pass/Fail Test based on Masks
R Vertical Sensitivity 1mV/div.
R 12div. x-Axis Display Range, 20div. y-Axis Display Range
(VirtualScreen)
R Trigger Modes: Slope, Video, Pulsewidth, Logic, Delayed, Event
R Component Tester, 6 Digit Counter, Automeasurement:
max. 6 Parameters incl. Statistic, Formula Editor, Ratiocursor,
FFT: 64kPts
R Fan: Silence redefined
R 3 x USB for Mass Storage, Printer and Remote Control
Display
Display:
Resolution:
Backlight:
Display area for traces:
without menu
with menu
Color depth:
Intensity steps per channel:
Vertical System
Channels:
DSO mode
MSO mode
Auxiliary input:
Function
Impedance
Coupling
Max. input voltage
XYZ-mode:
Invert:
Y-bandwidth (-3dB):
CH 1, CH 2 [CH 1CH 4]
CH 1, CH 2, LCH 07 (Logic Channels)
[CH 1, CH 2, LCH 07, CH 4]
with Option HO3508
Frontside [Rear side]
Ext. Trigger
1M || 13pF 2pF
DC, AC
100V (DC + peak AC)
All Analog Channels on individual choice
CH 1, CH 2 [CH 1CH 4]
70MHz (5mV10V)/div.
20MHz (1mV, 2mV)/div.
2Hz
Lower AC bandwidth:
Bandwidth limiter
approx. 20MHz
(switchable):
<5ns
Rise time (calculated):
2%
DC gain accuracy
13 calibrated steps
Input sensitivity:
CH 1, CH 2 [CH 1CH 4] 1mV/div.10V/div. (125 Sequence)
Between calibrated steps
Variable
Inputs CH 1, CH 2 [CH 1CH 4]:
1M II 14pF 2pF
Impedance
DC, AC, GND
Coupling
200V (DC + peak AC)
Max. input voltage
Measuring Category I (CAT I)
Measuring circuits:
10 Divs
Position range
With Option HO3508
Logic Channels
Select. switching
TTL, CMOS, ECL, User -2+8V
thresholds
100k || <4pF
Impedance
DC
Coupling
40V (DC + peak AC)
Max. input voltage:
Triggering
Analog Channels:
Automatic:
Min. signal height
Frequency range
Level control range
Normal (without peak):
Min. signal height
Frequency range
Level control range
Operating modes:
Slope:
Sources
Coupling
(Analog Channel)
Video:
Standards
Fields
Line
Sync. Impulse
Sources
Logic:
Sources
State
Duration
Pulses:
Modes
Range
Sources
Indicator for trigger action:
Ext. Trigger via:
2nd Trigger:
Slope
Min. signal height
Frequency range
Level control range
Operating modes
after time
after incidence
Serial Buses:
Option HOO10
Option HOO11
Option HOO12
Horizontal System
Domain representation:
Representation Time Base:
Memory Zoom:
Accuracy:
Time Base:
Roll Mode
Digital Storage
Sampling rate (real time):
Memory:
Operation modes:
Resolution (vertical):
Resolution (horizontal):
Interpolation:
Persistence:
Delay pretrigger:
posttrigger
Display refresh rate:
Display:
Reference memories:
Operation/Measuring/Interfaces
Menu-driven (multilingual), Autoset,
Operation:
help functions (multilingual)
typ. 10 complete instrument parameter
Save/Recall memories:
settings
Frequency counter:
6 Digit resolution
0.5Hz100MHz
50ppm
Accuracy
Amplitude, standard deviation,
Auto measurements:
Vpp, Vp+, Vp-, Vrms, Vavg, Vtop, Vbase,
frequency, period, pulse count,
twidth+, twidth-, tdutycycle+, tdutycycle-,
tRise10_90, tFall10_90, tRise20_80, tFall20_80,
pos. edge count, neg. edge count,
pos. pulse count, neg. pulse count,
trigger frequency, trigger period,
phase, delay
Min., max., mean, standard deviation,
Measurement statistic:
number of measurements for up to
6Functions
V, t, 1/t (f), V to Gnd, Vt related to
Cursor measurements:
Trigger point, ratio X and Y, pulse count,
peak to peak, peak+, peak-, mean value,
RMS value, standard deviation
Search- and Navigation functions for
Search functions:
specfic signal parameter
Dual-Interface USB type B/RS-232 (HO720),
Interface:
2 x USB type A (front- and rear side
each 1x) max. 100mA,
DVI-D for ext. Monitor
IEEE-488 (GPIB) (HO740),
Optional:
Dual-Interface Ethernet/USB (HO730)
Display functions
Marker:
VirtualScreen:
Busdisplay:
Mathematic functions
Number of formula sets:
Sources:
Targets:
Functions:
Display:
Pass/Fail functions
Sources:
Type of test:
Functions:
General Information
Component tester
Test voltage:
Test current:
Test frequency:
Reference Potential:
Probe ADJ Output:
Bus Signal Source:
Internal RTC
(Realtime clock):
Line voltage:
Power consumption:
Protective system:
Operating temperature:
Storage temperature:
Rel. humidity:
Theft protection:
Dimensions (W x H x D):
Weight:
HMO722/HMO724E/191212 C&E Subject to change without notice HAMEG Instruments GmbH DQS-certified in accordance with DIN EN ISO 9001:2008, Reg.-No.: 071040 QM08
HAMEG Instruments GmbH Industriestr. 6 D-63533 Mainhausen Tel +49(0)61828000 Fax +49(0)6182800100 www.hameg.com info@hameg.com
HOO10/HOO11
R HOO10 via Analog Channels and/or Logic Channels, HOO11 via Analog Channels
R I2C, SPI, UART/RS-232 Bus Trigger and Decode
R Hardware accelerated Decode in Real Time
R Color Coded Display of the Content for intuitive Analysis and easy Overview
R More Details of the decoded Values become visible with increasing Zoom Factor
R Bus Display with synchronous Display of the Data and, if selected, Clock Signal
R Decode into ASCII, Binary, Hexadecimal or Decimal Format
R Up to four Lines to comfortably show the decoded Values
R Powerful Trigger to isolate specific Messages
R Option for all Oscilloscopes of the HMO Series, retrofittable
SPI Bus
UART/RS-232 Bus
up to 10Mbit/s (HMO352x/2524),
up to 5Mbit/s (HMO72x202x)
up to 25Mbit/s (HMO352x/2524),
up to 12.5Mbit/s (HMO72x202x)
Number of Bits
Polarity
n/a
Parity
n/a
n/a
HOO10:
digital Channels LCH 015 (Opt. HO3508)
analog Channels CH 12 [CH 14]
HOO11:
analog Channels CH 12 [CH 14]
HOO10:
digital Channels LCH 015 (Opt. HO3508)
analog Channels CH 12, external
Trigger Entry for Chip Select, [CH 14]
HOO11:
analog Channels CH 12, external
Trigger Entry for Chip Select, [CH 14]
HOO10:
digital Channels LCH 015 (Opt. HO3508)
analog Channels CH 12 [CH 14]
HOO11:
analog Channels CH 12 [CH 14]
Event
7 or 10Bit Address ID
7 or 10Bit Address ID with 8Bit Data
Start, Stop, Restart
missing Acknowledge
Address ID without Acknowledge
Input format
Hexadecimal or Binary
Hexadecimal or Binary
Hexadecimal or Binary
HOO10:
digital Channels LCH 015 (Opt. HO3508)
analog Channels CH 12, external
Trigger Entry for Chip Select, [CH 14]
HOO11:
analog Channels CH 12, external
Trigger Entry for Chip Select, [CH 14]
HOO10:
digital Channels LCH 015 (Opt. HO3508)
analog Channels CH 12 [CH 14]
HOO11:
analog Channels CH 12 [CH 14]
Trigger
Source
Display
Format
Yellow
Magenta
Cyan
White
White
Green/Red
Red
Green
Data:
Start:
Stop:
Cyan
White
White
Data:
Start:
Stop:
Cyan
White
White
Error:
Trigger Condition:
Red
Green
Error:
Trigger Condition:
Red
Green
n/a
Data: ASCII, binary, decimal,
hexadecimal
n/a
Data: ASCII, binary, decimal,
hexadecimal
Differences HOO10/HOO11
Feature
HOO10
HOO11
Logic Channels (LCH 0LCH 15) as source for serial bus trigger and decode
Analog Channels (CH 1CH 4) as source for serial bus trigger and decode
HOO10/HOO11E/191212 C&E Subject to change without notice HAMEG Instruments GmbH DQS-certified in accordance with DIN EN ISO 9001:2008, Reg.-No.: 071040 QM08
HAMEG Instruments GmbH Industriestr. 6 D-63533 Mainhausen Tel +49(0)61828000 Fax +49(0)6182800100 www.hameg.com info@hameg.com
HOO12
LIN Bus
Pre-Defined or User-Select,
100Bit/s4Mb/s (HMO352x/ 2524),
100Bit/s2Mb/s (HMO72x202x)
Pre-Defined or User-Select,
100Bit/s4Mb/s (HMO352x/ 2524),
100Bit/s2Mb/s (HMO72x202x)
Signal Type
n/a
2590%
Pre-Defined or User-Select
n/a
n/a
n/a
Pre-Defined or User-Select
High or Low Active
1.x, 2.x, J2602, 1.x or 2.x
Event
Input format
Hexadecimal or Binary
Hexadecimal or Binary
Trigger
Source
Table
Format
White brackets
Magenta,
Yellow
White,
Cyan,
White
Green,
White,
Red
White brackets
Magenta,
White
Yellow,
Green,
Cyan
White,
Red,
Magenta
Display of Bus 0 or 1
Display of Bus 0 or 1
Frame Number
State (Frame Type or Error Description)
Start Time,
Identifier,
DLC,
CRC,
Data
Frame Number
State (Frame Type or Error Description)
Start Time,
Identifier,
Length,
Checksum,
Data
HOO12E/191212 C&E Subject to change without notice HAMEG Instruments GmbH DQS-certified in accordance with DIN EN ISO 9001:2008, Reg.-No.: 071040 QM08
HAMEG Instruments GmbH Industriestr. 6 D-63533 Mainhausen Tel +49(0)61828000 Fax +49(0)6182800100 www.hameg.com info@hameg.com